Effect of Radiant Exposure on the Physical and Mechanical Properties of 10 Flowable and High-viscosity Bulk-fill Resin Composites

被引:1
|
作者
de Deus, R. a [1 ]
Oliveira, L. r s [1 ]
Braga, S. s l [1 ]
Price, M. T. H. Ribeiro R. B. [1 ,2 ]
Nunez, A. [3 ]
Loguercio, A. d [4 ]
Soares, C. j [1 ,5 ]
机构
[1] Univ Fed Uberlandia, Sch Dent, Dept Operat Dent & Dent Mat, Uberlandia, MG, Brazil
[2] Dalhousie Univ, Dept Dent Clin Sci, Halifax, NS, Canada
[3] Univ Estadual Ponta Grossa, Ponta Grossa, PR, Brazil
[4] Univ Estadual Ponta Grossa, Sch Dent, Ponta Grossa, PR, Brazil
[5] 1720 Ave, Campus Umuarama, Block 2B, Room 2B24, BR-38400902 Uberlandia, MG, Brazil
关键词
IN-VITRO; SHRINKAGE STRESS; POLYMERIZATION SHRINKAGE; RESTORATIVE MATERIALS; MARGINAL ADAPTATION; CUSPAL DEFLECTION; CURING LIGHT; RADIOPACITY; MICROHARDNESS; RADIODENSITY;
D O I
10.2341/23-025-L
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives: To evaluate the effect of the different radiant exposures from a multipeak light curing unit on the physical and mechanical properties of flowable and high-viscosity bulk-fill resin-based composites (RBC). Methods: Five flowable bulk-fill RBCs (Tetric N-Flow Bulk-fill, Ivoclar Vivadent; Filtek Bulk Fill Flow, 3M Oral Care; Opus Bulk Fill Flow APS, FGM; Admira Fusion x-base, Voco and; and SDR Plus Bulk Fill Flowable, Dentsply Sirona) and five high-viscosity bulk-fill RBCs (Tetric N-Ceram Bulkfill, Ivoclar Vivadent; Filtek One Bulk Fill, 3M Oral Care; Opus Bulk Fill APS, FGM; Admira Fusion x-tra, Voco; and SonicFill 2, Kerr) were photocured using a VALO Cordless light (Ultradent) for 10, 20, and 40 seconds at an irradiance of 1200, 800, or 400 mW/cm(2), resulting in the delivery of 4, 8, 12, 16, 24, 32, or 48 J/cm(2). Post -gel shrinkage (Shr) was calculated using strain -gauge test. The degree of conversion (DC, %) was calculated using FTIR. Knoop hardness (KH, N/mm(2)) and elastic modulus (E, MPa) were measured at the top and bottom surfaces. Logarithmic regressions between the radiant exposures and mechanical properties were calculated. Radiodensity was calculated using digital radiographs. Data of Shr and radiodensity were analyzed using two-way analysis of variance (ANOVA), and the DC, KH, and E data were analyzed with two-way ANOVA using split -plot repeated measurement tests followed by the Tukey test (a=0.05). Results: Delivering higher radiant exposures produced higher Shr values (p<0.001) and higher DC values (R-2=0.808-0.922; R-2=0.648-0.914, p<0.001), KH (R-2=0.707-0.952; R-2=0.738-0.919; p<0.001), and E (R-2=0.501-0.925; R-2=0.823-0.919; p<0.001) values for the flowable and high -viscosity RBCs respectively. Lower KH, E and Shr were observed for the flowable bulk -fill RBCs. All bulkfill RBCs had a radiopacity level greater than the 4 -mm thick aluminum step wedge. The radiant exposure did not affect the radiopacity. Conclusion: The Shr, DC, KH, and E values were highly correlated to the radiant exposure delivered to the RBCs. The combination of the higher irradiance for longer exposure time that resulted in radiant exposure between 24 J/cm(2) to 48 J/cm(2) produced better results than delivering 400 mW/ cm(2) for 40 s (16 J/cm(2)), and 800 mW/cm(2) for 20 seconds (16 J/cm(2)) or 1200 mW/cm(2) for 10 seconds (12 J/cm(2)). All the bulk -fill RBCs were sufficiently radiopaque compared to 4 mm of aluminum.
引用
收藏
页码:136 / 156
页数:21
相关论文
共 50 条
  • [31] Physical and photoelastic properties of bulk-fill and conventional composites
    Pereira, Renata
    Caldas Giorgi, Maria Cecilia
    Esteves Lins, Rodrigo Barros
    Theobaldo, Essica Dias
    Nunes Leite Lima, Debora Alves
    Marchi, Giselle Maria
    Baggio Aguiar, Flavio Henrique
    [J]. CLINICAL COSMETIC AND INVESTIGATIONAL DENTISTRY, 2018, 10 : 287 - 296
  • [32] Effect of light-curing protocols on the mechanical behavior of bulk-fill resin composites
    Besegato, Joao Felipe
    Jussiani, Eduardo Inocente
    Andrello, Avacir Casanova
    Fernandes, Ricardo Vignoto
    Salomao, Fabio Martins
    Santana Vicentin, Bruno Luiz
    Dezan-Garbelini, Cassia Cilene
    Hoeppner, Marcio Grama
    [J]. JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2019, 90 : 381 - 387
  • [33] Effect of Preheating and Fatiguing on Mechanical Properties of Bulk-fill and Conventional Composite Resin
    Abdulmajeed, A. A.
    Donovan, T. E.
    Cook, R.
    Sulaiman, T. A.
    [J]. OPERATIVE DENTISTRY, 2020, 45 (04) : 387 - 395
  • [34] The effect of bleaching applications on stained bulk-fill resin composites
    Ayse Tugba Erturk-Avunduk
    Esra Cengiz-Yanardag
    Izgen Karakaya
    [J]. BMC Oral Health, 22
  • [35] The effect of bleaching applications on stained bulk-fill resin composites
    Erturk-Avunduk, Ayse Tugba
    Cengiz-Yanardag, Esra
    Karakaya, Izgen
    [J]. BMC ORAL HEALTH, 2022, 22 (01)
  • [36] Effect of food-simulating solvents on flexural properties of bulk-fill resin composites
    Marghalani, Hanadi Y.
    [J]. JOURNAL OF ORAL SCIENCE, 2021, 63 (01) : 31 - 36
  • [37] In vitro evaluation of microleakage in Class II composite restorations: High-viscosity bulk-fill vs conventional composites
    Garcia Mari, Laura
    Climent Gil, Arantxa
    Llena Puy, Carmen
    [J]. DENTAL MATERIALS JOURNAL, 2019, 38 (05) : 721 - 727
  • [38] Characterization of Inorganic Filler Content, Mechanical Properties, and Light Transmission of Bulk-fill Resin Composites
    Fronza, B. M.
    Ayres, A. P. A.
    Pacheco, R. R.
    Rueggeberg, F. A.
    Dias, C. T. S.
    Giannini, M.
    [J]. OPERATIVE DENTISTRY, 2017, 42 (04) : 445 - 455
  • [39] Bulk-fill resin composites: Polymerization properties and extended light curing
    Zorzin, Jose
    Maier, Eva
    Harre, Sarah
    Fey, Tobias
    Belli, Renan
    Lohbauer, Ulrich
    Petschelt, Anselm
    Taschner, Michael
    [J]. DENTAL MATERIALS, 2015, 31 (03) : 293 - 301
  • [40] Influence of resin matrix on the rheology, translucency, and curing potential of experimental flowable composites for bulk-fill applications
    Eiras Pereira, Leonardo Duarte
    Couto Neto, Mario Pereira
    Pereira, Roberto Guimaraes
    Schneider, Luis Felipe J.
    [J]. DENTAL MATERIALS, 2021, 37 (06) : 1046 - 1053