An empirical method for geometric calibration of a photon counting detector-based cone beam CT system

被引:0
|
作者
Ghani, Muhammad Usman [1 ]
Makeev, Andrey [1 ]
Manus, Joseph A. [1 ]
Glick, Stephen J. [1 ]
Ghammraoui, Bahaa [1 ]
机构
[1] United States Food & Drug Adm, Div Imaging Diagnost & Software Reliabil, Ctr Devices & Radiol Hlth, Off Sci & Engn Labs, Silver Spring, MD 20993 USA
关键词
Geometric calibration; sphericity; symmetry; photon counting detectors; cone beam CTs; COMPUTED-TOMOGRAPHY; PARAMETERS;
D O I
10.3233/XST-230007
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
BACKGROUND: Geometric calibration is essential in developing a reliable computed tomography (CT) system. It involves estimating the geometry under which the angular projections are acquired. Geometric calibration of cone beam CTs employing small area detectors, such as currently available photon counting detectors (PCDs), is challenging when using traditional-based methods due to detectors' limited areas. OBJECTIVE: This study presented an empirical method for the geometric calibration of small area PCD-based cone beam CT systems. METHODS: Unlike the traditional methods, we developed an iterative optimization procedure to determine geometric parameters using the reconstructed images of small metal ball bearings (BBs) embedded in a custom-built phantom. An objective function incorporating the sphericities and symmetries of the embedded BBs was defined to assess performance of the reconstruction algorithm with the given initial estimated set of geometric parameters. The optimal parameter values were those which minimized the objective function. The TIGRE toolbox was employed for fast tomographic reconstruction. To evaluate the proposed method, computer simulations were carried out using various numbers of spheres placed in various locations. Furthermore, efficacy of the method was experimentally assessed using a custom-made benchtop PCD-based cone beam CT. RESULTS: Computer simulations validated the accuracy and reproducibility of the proposed method. The precise estimation of the geometric parameters of the benchtop revealed high-quality imaging in CT reconstruction of a breast phantom. Within the phantom, the cylindrical holes, fibers, and speck groups were imaged in high fidelity. The CNR analysis further revealed the quantitative improvements of the reconstruction performed with the estimated parameters using the proposed method. CONCLUSION: Apart from the computational cost, we concluded that the method was easy to implement and robust.
引用
下载
收藏
页码:865 / 877
页数:13
相关论文
共 50 条
  • [1] A geometric calibration method for cone beam CT system
    Xiang Qian
    Wang Jue
    Cai Yufang
    EIGHTH INTERNATIONAL CONFERENCE ON DIGITAL IMAGE PROCESSING (ICDIP 2016), 2016, 10033
  • [2] Flat panel detector-based cone beam CT imaging: Preliminary system evaluation
    Ning, RL
    Conover, D
    Yu, Y
    Lu, XH
    MEDICAL IMAGING 2004: PHYSICS OF MEDICAL IMAGING, PTS 1 AND 2, 2004, 5368 : 616 - 620
  • [3] A geometric calibration method for cone beam CT systems
    Yang, Kai
    Kwan, Alexander L. C.
    Miller, DeWitt F.
    Boone, John M.
    MEDICAL PHYSICS, 2006, 33 (06) : 1695 - 1706
  • [4] Flat panel detector-based cone beam CT for dynamic imaging: System evaluation
    Ning, Ruola
    Conover, David
    Yu, Yong
    Zhang, Yan
    Cai, Weixing
    Yang, Dong
    Lu, Xianghua
    MEDICAL IMAGING 2006: PHYSICS OF MEDICAL IMAGING, PTS 1-3, 2006, 6142
  • [5] Flat panel detector-based cone beam volume CT imaging
    Ning, R
    MEDICAL PHYSICS, 2003, 30 (06) : 1370 - 1370
  • [6] Flat panel detector-based cone beam volume CT imaging: detector evaluation
    Ning, R
    Tang, XY
    Yu, RF
    Conover, D
    Zhang, DH
    MEDICAL IMAGING 1999: PHYSICS OF MEDICAL IMAGING, PTS 1 AND 2, 1999, 3659 : 192 - 203
  • [7] Preliminary system characterization of flat panel detector-based cone beam CT for breast imaging
    Ning, RL
    Yu, Y
    Conover, D
    Lu, XH
    He, HG
    Chen, ZK
    Schiffhauer, L
    Cullinan, J
    MEDICAL IMAGING 2004: PHYSICS OF MEDICAL IMAGING, PTS 1 AND 2, 2004, 5368 : 292 - 303
  • [8] Flat panel detector-based cone beam CT lung imaging: preliminary system evaluation
    Ning, R
    Conover, D
    Yu, Y
    Cai, WX
    Lu, XH
    MEDICAL IMAGING 2005: PHYSICS OF MEDICAL IMAGING, PTS 1 AND 2, 2005, 5745 : 147 - 158
  • [9] An interval subdividing based method for geometric calibration of cone-beam CT
    Tan, Shengqi
    Cong, Peng
    Liu, Ximing
    Wu, Zhifang
    NDT & E INTERNATIONAL, 2013, 58 : 49 - 55
  • [10] Geometric calibration of micro-cone-beam CT system
    Chityala, R
    Hoffmann, K
    Ionita, C
    Bednarek, D
    Rudin, S
    MEDICAL PHYSICS, 2004, 31 (06) : 1820 - 1820