Flat panel detector-based cone beam CT for dynamic imaging: System evaluation

被引:2
|
作者
Ning, Ruola [1 ]
Conover, David [1 ]
Yu, Yong [1 ]
Zhang, Yan [1 ]
Cai, Weixing [1 ]
Yang, Dong [1 ]
Lu, Xianghua [1 ]
机构
[1] Univ Rochester, Dept Imaging Sci, Rochester, NY 14642 USA
关键词
D O I
10.1117/12.655717
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The purpose of this study is to characterize a newly built flat panel detector (FPD)-based cone beam CT (CBCT) prototype for dynamic imaging. A CBCT prototype has been designed and constructed by completely modifying a GE HiSpeed Advantage (HSA) CT gantry, incorporating a newly acquired large size real-time FPD (Varian PaxScan 4030CB), a new x-ray generator and a dual focal spot angiography x-ray tube that allows the full coverage of the detector. During data acquisition, the x-ray tube and the FPD can be rotated on the gantry over Nx360 degrees due to integrated slip ring technology with the rotation speed of one second/revolution. With a single scan time of up to 40 seconds, multiple sets of reconstructions can be performed for dynamic studies. The upgrade of this system has been completed. The prototype was used for a series of preliminary phantom studies: different sizes of breast phantoms, a Humanoid chest phantom and scatter correction studies. The results of the phantom studies demonstrate that good image quality can be achieved with this newly built prototype.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] Flat panel detector-based cone beam CT imaging: Preliminary system evaluation
    Ning, RL
    Conover, D
    Yu, Y
    Lu, XH
    [J]. MEDICAL IMAGING 2004: PHYSICS OF MEDICAL IMAGING, PTS 1 AND 2, 2004, 5368 : 616 - 620
  • [2] Flat panel detector-based cone beam volume CT imaging: detector evaluation
    Ning, R
    Tang, XY
    Yu, RF
    Conover, D
    Zhang, DH
    [J]. MEDICAL IMAGING 1999: PHYSICS OF MEDICAL IMAGING, PTS 1 AND 2, 1999, 3659 : 192 - 203
  • [3] Flat panel detector-based cone beam CT lung imaging: preliminary system evaluation
    Ning, R
    Conover, D
    Yu, Y
    Cai, WX
    Lu, XH
    [J]. MEDICAL IMAGING 2005: PHYSICS OF MEDICAL IMAGING, PTS 1 AND 2, 2005, 5745 : 147 - 158
  • [4] Flat panel detector-based cone beam volume CT imaging
    Ning, R
    [J]. MEDICAL PHYSICS, 2003, 30 (06) : 1370 - 1370
  • [5] Flat panel detector-based cone-beam volume CT angiography imaging: System evaluation
    Ning, R
    Chen, B
    Yu, RF
    Conover, D
    Tang, XY
    Ning, Y
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 2000, 19 (09) : 949 - 963
  • [6] Flat panel detector-based cone-beam volume CT breast imaging: detector evaluation
    Yu, Y
    Conover, D
    Ning, RL
    [J]. MEDICAL IMAGING 2003: PHYSICS OF MEDICAL IMAGING, PTS 1 AND 2, 2003, 5030 : 711 - 719
  • [7] Preliminary system characterization of flat panel detector-based cone beam CT for breast imaging
    Ning, RL
    Yu, Y
    Conover, D
    Lu, XH
    He, HG
    Chen, ZK
    Schiffhauer, L
    Cullinan, J
    [J]. MEDICAL IMAGING 2004: PHYSICS OF MEDICAL IMAGING, PTS 1 AND 2, 2004, 5368 : 292 - 303
  • [8] Flat panel detector-based cone beam volume CT breast imaging: Phantom study
    Ning, R
    Chen, B
    Conover, D
    McHugh, L
    Cullinan, JA
    Robinson, AE
    [J]. RADIOLOGY, 2001, 221 : 544 - 544
  • [9] Flat panel detector-based cone beam volume CT breast imaging: preliminary phantom study
    Ning, RL
    Chen, BA
    Conover, D
    McHugh, L
    Cullinan, J
    Yu, RF
    [J]. MEDICAL IMAGING 2001: PHYSICS OF MEDICAL IMAGING, 2001, 4320 : 601 - 610
  • [10] Flat panel detector-based cone beam volume CT breast imaging: phantom and specimen study
    Ning, R
    Conover, D
    Chen, B
    Schiffhauer, L
    Cullinan, J
    Ning, Y
    Robinson, A
    [J]. MEDICAL IMAGING 2002: PHYSICS OF MEDICAL IMAGING, 2002, 4682 : 218 - 227