An empirical method for geometric calibration of a photon counting detector-based cone beam CT system

被引:0
|
作者
Ghani, Muhammad Usman [1 ]
Makeev, Andrey [1 ]
Manus, Joseph A. [1 ]
Glick, Stephen J. [1 ]
Ghammraoui, Bahaa [1 ]
机构
[1] United States Food & Drug Adm, Div Imaging Diagnost & Software Reliabil, Ctr Devices & Radiol Hlth, Off Sci & Engn Labs, Silver Spring, MD 20993 USA
关键词
Geometric calibration; sphericity; symmetry; photon counting detectors; cone beam CTs; COMPUTED-TOMOGRAPHY; PARAMETERS;
D O I
10.3233/XST-230007
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
BACKGROUND: Geometric calibration is essential in developing a reliable computed tomography (CT) system. It involves estimating the geometry under which the angular projections are acquired. Geometric calibration of cone beam CTs employing small area detectors, such as currently available photon counting detectors (PCDs), is challenging when using traditional-based methods due to detectors' limited areas. OBJECTIVE: This study presented an empirical method for the geometric calibration of small area PCD-based cone beam CT systems. METHODS: Unlike the traditional methods, we developed an iterative optimization procedure to determine geometric parameters using the reconstructed images of small metal ball bearings (BBs) embedded in a custom-built phantom. An objective function incorporating the sphericities and symmetries of the embedded BBs was defined to assess performance of the reconstruction algorithm with the given initial estimated set of geometric parameters. The optimal parameter values were those which minimized the objective function. The TIGRE toolbox was employed for fast tomographic reconstruction. To evaluate the proposed method, computer simulations were carried out using various numbers of spheres placed in various locations. Furthermore, efficacy of the method was experimentally assessed using a custom-made benchtop PCD-based cone beam CT. RESULTS: Computer simulations validated the accuracy and reproducibility of the proposed method. The precise estimation of the geometric parameters of the benchtop revealed high-quality imaging in CT reconstruction of a breast phantom. Within the phantom, the cylindrical holes, fibers, and speck groups were imaged in high fidelity. The CNR analysis further revealed the quantitative improvements of the reconstruction performed with the estimated parameters using the proposed method. CONCLUSION: Apart from the computational cost, we concluded that the method was easy to implement and robust.
引用
收藏
页码:865 / 877
页数:13
相关论文
共 50 条
  • [41] Photon-counting-detector CT outperforms state-of-the-art cone-beam and energy-integrated-detector CT in delineation of dental root canals
    Stephan Rau
    Martin Peter Pichotka
    Alexander Rau
    Marco Reisert
    Markus Jörg Altenburger
    Rainer Schmelzeisen
    Fabian Cieplik
    Fabian Bamberg
    Maximilian Frederik Russe
    Wiebke Semper-Hogg
    Scientific Reports, 15 (1)
  • [42] Fast cone-beam computed tomography geometric calibration method based on measuring tools
    Zhang C.
    Huang K.
    Chen H.
    Yi Qi Yi Biao Xue Bao/Chinese Journal of Scientific Instrument, 2019, 40 (01): : 175 - 182
  • [43] FDK Half-Scan lengwith a Heuristic Weighting Scheme on a Flat Panel Detector-Based Cone Beam CT (FDKHSCW)
    Yang, Dong
    Ning, Ruola
    INTERNATIONAL JOURNAL OF BIOMEDICAL IMAGING, 2006, 2006
  • [44] Detector-based calibration method for high-accuracy solar UV measurements
    Karha, P
    Visuri, R
    Leszczynski, K
    Manoochehri, F
    Jokela, K
    Ikonen, E
    PHOTOCHEMISTRY AND PHOTOBIOLOGY, 1996, 64 (02) : 340 - 343
  • [45] Photon Counting X-ray CT System with a Semiconductor Detector
    Kowase, Kazuhiko
    Ogawa, Koichi
    2006 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOL 1-6, 2006, : 3119 - 3123
  • [46] An empirical method for lag correction in cone-beam CT
    Mail, N.
    Moseley, D. J.
    Siewerdsen, J. H.
    Jaffray, D. A.
    MEDICAL PHYSICS, 2008, 35 (11) : 5187 - 5196
  • [47] An empirical method for lag correction in cone-beam CT
    Mail, N.
    Moseley, D.
    Siewerdsen, J.
    Jaftray, D.
    MEDICAL PHYSICS, 2007, 34 (06) : 2342 - 2342
  • [48] Rhinolithiasis: the importance of flat panel detector-based cone beam computed tomography in diagnosis and treatment
    Sumbullu, M. Akif
    Tozoglu, Ummuhan
    Yoruk, Ozgur
    Yilmaz, A. Berhan
    Ucuncu, Harun
    ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTOLOGY, 2009, 107 (06): : E65 - E67
  • [49] Analytic non-iterative method for geometric calibration of cone-beam computerized tomography system
    Cho, Y
    Moseley, D
    Siewerdsen, J
    Jaffray, D
    MEDICAL PHYSICS, 2003, 30 (06) : 1450 - 1450
  • [50] Geometric calibration for a dual tube/detector micro-CT system
    Johnston, Samuel M.
    Johnson, G. Allan
    Badeaa, Cristian T.
    MEDICAL PHYSICS, 2008, 35 (05) : 1820 - 1829