An empirical method for geometric calibration of a photon counting detector-based cone beam CT system

被引:0
|
作者
Ghani, Muhammad Usman [1 ]
Makeev, Andrey [1 ]
Manus, Joseph A. [1 ]
Glick, Stephen J. [1 ]
Ghammraoui, Bahaa [1 ]
机构
[1] United States Food & Drug Adm, Div Imaging Diagnost & Software Reliabil, Ctr Devices & Radiol Hlth, Off Sci & Engn Labs, Silver Spring, MD 20993 USA
关键词
Geometric calibration; sphericity; symmetry; photon counting detectors; cone beam CTs; COMPUTED-TOMOGRAPHY; PARAMETERS;
D O I
10.3233/XST-230007
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
BACKGROUND: Geometric calibration is essential in developing a reliable computed tomography (CT) system. It involves estimating the geometry under which the angular projections are acquired. Geometric calibration of cone beam CTs employing small area detectors, such as currently available photon counting detectors (PCDs), is challenging when using traditional-based methods due to detectors' limited areas. OBJECTIVE: This study presented an empirical method for the geometric calibration of small area PCD-based cone beam CT systems. METHODS: Unlike the traditional methods, we developed an iterative optimization procedure to determine geometric parameters using the reconstructed images of small metal ball bearings (BBs) embedded in a custom-built phantom. An objective function incorporating the sphericities and symmetries of the embedded BBs was defined to assess performance of the reconstruction algorithm with the given initial estimated set of geometric parameters. The optimal parameter values were those which minimized the objective function. The TIGRE toolbox was employed for fast tomographic reconstruction. To evaluate the proposed method, computer simulations were carried out using various numbers of spheres placed in various locations. Furthermore, efficacy of the method was experimentally assessed using a custom-made benchtop PCD-based cone beam CT. RESULTS: Computer simulations validated the accuracy and reproducibility of the proposed method. The precise estimation of the geometric parameters of the benchtop revealed high-quality imaging in CT reconstruction of a breast phantom. Within the phantom, the cylindrical holes, fibers, and speck groups were imaged in high fidelity. The CNR analysis further revealed the quantitative improvements of the reconstruction performed with the estimated parameters using the proposed method. CONCLUSION: Apart from the computational cost, we concluded that the method was easy to implement and robust.
引用
收藏
页码:865 / 877
页数:13
相关论文
共 50 条
  • [31] Self-Geometric Calibration of Circular Cone Beam CT Based On Epipolar Geometry Consistency
    Zheng, Liang
    Luo, Shouhua
    Chen, Lujie
    Luo, Shuang
    MEDICAL IMAGING 2019: PHYSICS OF MEDICAL IMAGING, 2019, 10948
  • [32] Patient-specific scatter correction for flat-panel detector-based cone-beam CT imaging
    Zhao, Wei
    Brunner, Stephen
    Niu, Kai
    Schafer, Sebastian
    Royalty, Kevin
    Chen, Guang-Hong
    PHYSICS IN MEDICINE AND BIOLOGY, 2015, 60 (03): : 1339 - 1365
  • [33] Modified FDK half-scan (MFDKHS) scheme on flat panel detector-based cone-beam CT
    Yang, D
    Ning, RL
    Yu, Y
    Conover, D
    Lu, XH
    Medical Imaging 2005: Physics of Medical Imaging, Pts 1 and 2, 2005, 5745 : 1030 - 1037
  • [34] Development of a Benchtop Photon Counting Cone-Beam CT System with a Translate-Rotate Geometry
    Bader, A. M.
    Makeev, A.
    Glick, S. J.
    Ghammraoui, B.
    MEDICAL IMAGING 2020: PHYSICS OF MEDICAL IMAGING, 2020, 11312
  • [35] A pixel detector-based single photon-counting system as fast spectrometer for diagnostic X-ray beams
    Carpentieri, C.
    Bisogni, M. G.
    Del Guerra, A.
    Delogu, P.
    Fantacci, M. E.
    Fogli, J.
    Marchi, A.
    Marzulli, V.
    Rosso, V.
    Stefanini, A.
    Tofani, A.
    RADIATION PROTECTION DOSIMETRY, 2008, 129 (1-3) : 119 - 122
  • [36] A line fiducial method for geometric calibration of cone-beam CT systems with diverse scan trajectories
    Jacobson, M. W.
    Ketcha, M. D.
    Capostagno, S.
    Martin, A.
    Uneri, A.
    Goerres, J.
    De Silva, T.
    Reaungamornrat, S.
    Han, R.
    Manbachi, A.
    Stayman, J. W.
    Vogt, S.
    Kleinszig, G.
    Siewerdsen, J. H.
    PHYSICS IN MEDICINE AND BIOLOGY, 2018, 63 (02):
  • [37] Energy-sensitive photon counting detector-based X-ray computed tomography
    Taguchi K.
    Radiological Physics and Technology, 2017, 10 (1) : 8 - 22
  • [38] Geometric Parameters Estimation and Calibration in Cone-Beam Micro-CT
    Zhao, Jintao
    Hu, Xiaodong
    Zou, Jing
    Hu, Xiaotang
    SENSORS, 2015, 15 (09) : 22811 - 22825
  • [39] Accurate geometric calibration of linac-mounted cone beam CT systems
    Hemsley, Matt
    Ali, Elsayed
    Clackdoyle, Rolf
    Xu, Tong
    MEDICAL PHYSICS, 2017, 44 (08) : 4383 - 4383
  • [40] An Analytical Geometric Calibration Method for Circular Cone-Beam Geometry
    Xu, Jingyan
    Tsui, Benjamin M. W.
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2013, 32 (09) : 1731 - 1744