An empirical method for geometric calibration of a photon counting detector-based cone beam CT system

被引:0
|
作者
Ghani, Muhammad Usman [1 ]
Makeev, Andrey [1 ]
Manus, Joseph A. [1 ]
Glick, Stephen J. [1 ]
Ghammraoui, Bahaa [1 ]
机构
[1] United States Food & Drug Adm, Div Imaging Diagnost & Software Reliabil, Ctr Devices & Radiol Hlth, Off Sci & Engn Labs, Silver Spring, MD 20993 USA
关键词
Geometric calibration; sphericity; symmetry; photon counting detectors; cone beam CTs; COMPUTED-TOMOGRAPHY; PARAMETERS;
D O I
10.3233/XST-230007
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
BACKGROUND: Geometric calibration is essential in developing a reliable computed tomography (CT) system. It involves estimating the geometry under which the angular projections are acquired. Geometric calibration of cone beam CTs employing small area detectors, such as currently available photon counting detectors (PCDs), is challenging when using traditional-based methods due to detectors' limited areas. OBJECTIVE: This study presented an empirical method for the geometric calibration of small area PCD-based cone beam CT systems. METHODS: Unlike the traditional methods, we developed an iterative optimization procedure to determine geometric parameters using the reconstructed images of small metal ball bearings (BBs) embedded in a custom-built phantom. An objective function incorporating the sphericities and symmetries of the embedded BBs was defined to assess performance of the reconstruction algorithm with the given initial estimated set of geometric parameters. The optimal parameter values were those which minimized the objective function. The TIGRE toolbox was employed for fast tomographic reconstruction. To evaluate the proposed method, computer simulations were carried out using various numbers of spheres placed in various locations. Furthermore, efficacy of the method was experimentally assessed using a custom-made benchtop PCD-based cone beam CT. RESULTS: Computer simulations validated the accuracy and reproducibility of the proposed method. The precise estimation of the geometric parameters of the benchtop revealed high-quality imaging in CT reconstruction of a breast phantom. Within the phantom, the cylindrical holes, fibers, and speck groups were imaged in high fidelity. The CNR analysis further revealed the quantitative improvements of the reconstruction performed with the estimated parameters using the proposed method. CONCLUSION: Apart from the computational cost, we concluded that the method was easy to implement and robust.
引用
下载
收藏
页码:865 / 877
页数:13
相关论文
共 50 条
  • [21] Geometry calibration for a dental cone-beam CT system with an offset detector
    Hwang, Jaehong
    Kim, Hyeongseok
    Lee, Taewon
    Choi, Da-in
    Kwon, Taejin
    Cho, Seungryong
    PRECISION ENGINEERING-JOURNAL OF THE INTERNATIONAL SOCIETIES FOR PRECISION ENGINEERING AND NANOTECHNOLOGY, 2023, 79 : 264 - 276
  • [22] Flat panel detector-based cone beam volume CT breast imaging: preliminary phantom study
    Ning, RL
    Chen, BA
    Conover, D
    McHugh, L
    Cullinan, J
    Yu, RF
    MEDICAL IMAGING 2001: PHYSICS OF MEDICAL IMAGING, 2001, 4320 : 601 - 610
  • [23] Flat panel detector-based cone beam volume CT breast imaging: phantom and specimen study
    Ning, R
    Conover, D
    Chen, B
    Schiffhauer, L
    Cullinan, J
    Ning, Y
    Robinson, A
    MEDICAL IMAGING 2002: PHYSICS OF MEDICAL IMAGING, 2002, 4682 : 218 - 227
  • [24] Geometric Calibration of a Dual Cone Beam CT System with Large Flat Panel Detectors
    Li, H.
    Bowsher, J.
    Giles, W.
    Roper, J.
    Li, T.
    Yin, F.
    MEDICAL PHYSICS, 2009, 36 (06)
  • [26] A geometric calibration approach for an industrial cone-beam CT system based on a low-rank phantom
    Yu, Jianqiao
    Lu, Jian
    Sun, Yi
    Liu, Jishun
    Cheng, Kai
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2022, 33 (03)
  • [27] GEOMETRIC CALIBRATION METHOD FOR MULTIPLE-HEAD CONE-BEAM SPECT SYSTEM
    RIZO, P
    GRANGEAT, P
    GUILLEMAUD, R
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1994, 41 (06) : 2748 - 2757
  • [28] Analytical geometric parameter calibration algorithm for cone-beam CT
    Chen, Lian
    Wu, Zhifang
    Liu, Ximing
    Yao, Ming
    Qinghua Daxue Xuebao/Journal of Tsinghua University, 2010, 50 (03): : 418 - 421
  • [29] Influence of Threshold Calibration On CT Image Quality of a Photon-Counting Detector
    Rodesch, P.
    Richtsmeier, D.
    Zalavari, L.
    Bazalova-Carter, M.
    MEDICAL PHYSICS, 2022, 49 (06) : E174 - E174
  • [30] Real time flat panel detector-based cone beam volume CT breast imaging: phantom and specimen study
    Ning, R
    Conover, D
    Yu, Y
    Schiffhauer, L
    Lu, XH
    Cullinan, J
    Robinson, A
    MEDICAL IMAGING 2003: PHYSICS OF MEDICAL IMAGING, PTS 1 AND 2, 2003, 5030 : 181 - 190