Validation of virtual sensor-assisted Bayesian inference-based in-situ sensor calibration strategy for building HVAC systems

被引:22
|
作者
Li, Guannan [1 ]
Xiong, Jiahao [1 ]
Sun, Shaobo [2 ]
Chen, Jian [1 ]
机构
[1] Wuhan Univ Sci & Technol, Sch Urban Construct, Wuhan 430065, Peoples R China
[2] Hong Kong Polytech Univ, Dept Bldg Environm & Energy Engn, Hong Kong, Peoples R China
基金
中国国家自然科学基金;
关键词
heating; ventilation and air-conditioning (HVAC); in-situ sensor calibration; Bayesian inference (BI); virtual sensor (VS); influencing factor; energy conservation (EC); FAULT-DIAGNOSIS METHOD; TOLERANT CONTROL; NEURAL-NETWORK; HIDDEN FACTORS; ENERGY MODELS; ACCURACY; PREDICTION; REGRESSION;
D O I
10.1007/s12273-022-0935-7
中图分类号
O414.1 [热力学];
学科分类号
摘要
For building heating, ventilation and air-conditioning systems (HVACs), sensor faults significantly affect the operation and control. Sensors with accurate and reliable measurements are critical for ensuring the precise indoor thermal demand. Owing to its high calibration accuracy and in-situ effectiveness, a virtual sensor (VS)-assisted Bayesian inference (VS-BI) sensor calibration strategy has been applied for HVACs. However, the application feasibility of this strategy for wider ranges of different sensor types (within-control-loop and out-of-control-loop) with various sensor bias fault amplitudes, and influencing factors that affect the practical in-situ calibration performance are still remained to be explored. Hence, to further validate its in-situ calibration performance and analyze the influencing factors, this study applied the VS-BI strategy in a HVAC system including a chiller plant with air handle unit (AHU) terminal. Three target sensors including air supply (SAT), chilled water supply (CHS) and cooling water return (CWR) temperatures are investigated using introduced sensor bias faults with eight different amplitudes of [-2 degrees C, +2 degrees C] with a 0.5 degrees C interval. Calibration performance is evaluated by considering three influencing factors: (1) performance of different data-driven VSs, (2) the influence of prior standard deviations sigma on in-situ sensor calibration and (3) the influence of data quality on in-situ sensor calibration from the perspective of energy conservation and data volumes. After comparison, a long short term memory (LSTM) is adopted for VS construction with determination coefficient R-squared of 0.984. Results indicate that sigma has almost no impact on calibration accuracy of CHS but scanty impact on that of SAT and CWR. The potential of using a prior standard deviation sigma to improve the calibration accuracy is limited, only 8.61% on average. For system within-control-loop sensors like SAT and CHS, VS-BI obtains relatively high in-situ sensor calibration accuracy if the data quality is relatively high.
引用
收藏
页码:185 / 203
页数:19
相关论文
共 47 条
  • [21] Effects of various partitions on the accuracy of virtual in-situ calibration in building energy systems
    Li, Jiteng
    Zhao, Tianyi
    Wang, Peng
    Yoon, Sungmin
    Yu, Yuebin
    JOURNAL OF BUILDING ENGINEERING, 2020, 32
  • [22] A quantitative comparison of statistical and deterministic methods on virtual in-situ calibration in building systems
    Yoon, Sungmin
    Yu, Yuebin
    BUILDING AND ENVIRONMENT, 2017, 115 : 54 - 66
  • [23] A Comparison of Stochastic and Deterministic Optimization Algorithms on Virtual In-situ Calibration in Building Systems
    Yoon, Sungmin
    Yu, Yuebin
    2017 ASHRAE WINTER CONFERENCE PAPERS, 2017,
  • [24] Bayesian inference-based environmental decision support systems for oil spill response strategy selection
    Davies, Andrew J.
    Hope, Max J.
    MARINE POLLUTION BULLETIN, 2015, 96 (1-2) : 87 - 102
  • [25] Real-Time In-Situ Calibration for Angle Measuring Sensor Based on Autocollimator
    Zhang W.
    Zhu H.
    Li M.
    Guo Z.
    Guo M.
    Zhongguo Jiguang/Chinese Journal of Lasers, 2019, 46 (04):
  • [26] Real-Time In-Situ Calibration for Angle Measuring Sensor Based on Autocollimator
    Zhang Wenying
    Zhu Haoran
    Li Meixuan
    Guo Zexuan
    Guo Ming
    CHINESE JOURNAL OF LASERS-ZHONGGUO JIGUANG, 2019, 46 (04):
  • [27] Variational Bayesian Inference-Based Counting and Localization for Off-Grid Targets With Faulty Prior Information in Wireless Sensor Networks
    Guo, Yan
    Sun, Baoming
    Li, Ning
    Fang, Dagang
    IEEE TRANSACTIONS ON COMMUNICATIONS, 2018, 66 (03) : 1273 - 1283
  • [28] Calibration of an in-situ fluorescence based sensor platform for reliable BOD5 measurement in wastewater
    Khamis, K.
    Bradley, C.
    Gunter, H. J.
    Basevi, G.
    Stevens, R.
    Hannah, D. M.
    WATER SCIENCE AND TECHNOLOGY, 2021, 83 (12) : 3075 - 3091
  • [29] In-situ Calibration Method for Dual-sensor Weighing System Based on Sensitivity Change Mechanism
    Huang J.
    Lin S.
    Huang W.
    Li J.
    Gongcheng Kexue Yu Jishu/Advanced Engineering Sciences, 2020, 52 (04): : 213 - 217
  • [30] In-situ validation of embedded physics-based calibration in low-cost particulate matter sensor for urban air quality monitoring
    Feng, Zikang
    Zheng, Lina
    Ren, Bilin
    URBAN CLIMATE, 2025, 59