Validation of virtual sensor-assisted Bayesian inference-based in-situ sensor calibration strategy for building HVAC systems

被引:22
|
作者
Li, Guannan [1 ]
Xiong, Jiahao [1 ]
Sun, Shaobo [2 ]
Chen, Jian [1 ]
机构
[1] Wuhan Univ Sci & Technol, Sch Urban Construct, Wuhan 430065, Peoples R China
[2] Hong Kong Polytech Univ, Dept Bldg Environm & Energy Engn, Hong Kong, Peoples R China
基金
中国国家自然科学基金;
关键词
heating; ventilation and air-conditioning (HVAC); in-situ sensor calibration; Bayesian inference (BI); virtual sensor (VS); influencing factor; energy conservation (EC); FAULT-DIAGNOSIS METHOD; TOLERANT CONTROL; NEURAL-NETWORK; HIDDEN FACTORS; ENERGY MODELS; ACCURACY; PREDICTION; REGRESSION;
D O I
10.1007/s12273-022-0935-7
中图分类号
O414.1 [热力学];
学科分类号
摘要
For building heating, ventilation and air-conditioning systems (HVACs), sensor faults significantly affect the operation and control. Sensors with accurate and reliable measurements are critical for ensuring the precise indoor thermal demand. Owing to its high calibration accuracy and in-situ effectiveness, a virtual sensor (VS)-assisted Bayesian inference (VS-BI) sensor calibration strategy has been applied for HVACs. However, the application feasibility of this strategy for wider ranges of different sensor types (within-control-loop and out-of-control-loop) with various sensor bias fault amplitudes, and influencing factors that affect the practical in-situ calibration performance are still remained to be explored. Hence, to further validate its in-situ calibration performance and analyze the influencing factors, this study applied the VS-BI strategy in a HVAC system including a chiller plant with air handle unit (AHU) terminal. Three target sensors including air supply (SAT), chilled water supply (CHS) and cooling water return (CWR) temperatures are investigated using introduced sensor bias faults with eight different amplitudes of [-2 degrees C, +2 degrees C] with a 0.5 degrees C interval. Calibration performance is evaluated by considering three influencing factors: (1) performance of different data-driven VSs, (2) the influence of prior standard deviations sigma on in-situ sensor calibration and (3) the influence of data quality on in-situ sensor calibration from the perspective of energy conservation and data volumes. After comparison, a long short term memory (LSTM) is adopted for VS construction with determination coefficient R-squared of 0.984. Results indicate that sigma has almost no impact on calibration accuracy of CHS but scanty impact on that of SAT and CWR. The potential of using a prior standard deviation sigma to improve the calibration accuracy is limited, only 8.61% on average. For system within-control-loop sensors like SAT and CHS, VS-BI obtains relatively high in-situ sensor calibration accuracy if the data quality is relatively high.
引用
收藏
页码:185 / 203
页数:19
相关论文
共 47 条
  • [31] Learning-based Framework for Sensor Fault-Tolerant Building HVAC Control with Model-assisted Learning
    Xu, Shichao
    Fu, Yangyang
    Wang, Yixuan
    O'Neill, Zheng
    Zhu, Qi
    BUILDSYS'21: PROCEEDINGS OF THE 2021 ACM INTERNATIONAL CONFERENCE ON SYSTEMS FOR ENERGY-EFFICIENT BUILT ENVIRONMENTS, 2021, : 1 - 10
  • [32] Sensor Calibration using In-Situ Celestial Observations to Estimate Bias in Space-Based Missile Tracking
    Clemons, Thomas M., III
    Chang, Kuo-Chu
    IEEE TRANSACTIONS ON AEROSPACE AND ELECTRONIC SYSTEMS, 2012, 48 (02) : 1403 - 1427
  • [33] In-situ Calibration Method of Fiber Grating Strain Sensor Based on Data Sequence Matching and Statistical Analysis
    Cai Jingyi
    Wu Jieya
    Zhao Chunliu
    Kang Juan
    Gong Huaping
    ACTA PHOTONICA SINICA, 2022, 51 (06)
  • [34] Sensor validation and reconstruction for building central chilling systems based on principal component analysis
    Wang, SW
    Chen, YM
    ENERGY CONVERSION AND MANAGEMENT, 2004, 45 (05) : 673 - 695
  • [35] Fuzzy inference logic assisted rendezvous points based effective routing strategy in wireless sensor networks
    Chakraborty, Sujay
    Raghuvanshi, Ajay Singh
    INTERNATIONAL JOURNAL OF COMMUNICATION SYSTEMS, 2024, 37 (12)
  • [36] Law-based sensor fault diagnosis and validation for building air-conditioning systems
    Wang, Shengwei
    Wang, Jin-Bo
    HVAC and R Research, 1999, 5 (04): : 353 - 380
  • [37] Law-based sensor fault diagnosis and validation for building air-conditioning systems
    Wang, SW
    Wang, JB
    HVAC&R RESEARCH, 1999, 5 (04): : 353 - 380
  • [38] An agent-based distributed real-time optimal control strategy for building HVAC systems for applications in the context of future IoT-based smart sensor networks
    Su, Bing
    Wang, Shengwei
    APPLIED ENERGY, 2020, 274
  • [39] Improvement for energy efficiency and control characteristics in variable air volume system using in-situ sensor calibration method based on autoencoder
    Li, Jiteng
    Wang, Peng
    Li, Jiqing
    Xing, Han
    Zhao, Tianyi
    Yoon, Sungmin
    JOURNAL OF BUILDING ENGINEERING, 2023, 63
  • [40] In-situ service load monitoring of automotive electronic systems using silicon-based piezoresistive stress sensor
    Yang, Yu-Hsiang
    Han, Bongtae
    Prisacaru, Alexandru
    Gromala, Przemyslaw
    Jiang, Shengbing
    Sarwar, Azeem
    MICROELECTRONICS RELIABILITY, 2020, 110