摘要
The Ritchey-Common test is widely adopted to measure large optical flats. The traditional Ritchey-Common test eliminates the defocus error with multiple tests by changing the position of the mirrors, which suffers from cumbersome steps, poor repeatability, coupled system error, extra mirror deformation, and potential overturning. The above problems increase the test time, decrease the reliability and accuracy, increase the test cost, and threaten manufacturing safety. We propose a single-test Ritchey-Common interferometry to avoid the obligatory position change in the traditional method. A sub-aperture of test flat is directly measured by a small-aperture interferometer before the test, which is easy to implement, to replace the extra system wavefront measurement in different positions. The defocus is calculated in sub-aperture at exactly the same position as the full-field measurement without the position change, then the surface form under test can be obtained with accurate optical path modeling. Measurement experiments for 100 mm and 2050 mm aperture flats were performed to demonstrate the feasibility of this method. Compared with a direct test in a standard Zygo interferometer, the peak to valley (PV) and root mean square (RMS) errors were 0.0889 ? and 0.0126 ? (?=632.8 nm), respectively, which reaches the upper limit of accuracy of the interferometer. To the best of our knowledge, this is the first proposal of the Ritchey-Common test that can eliminate the defocus error and realize high accuracy measurement in a single test. Our work paves the way for reliable and practical optical metrology for large optical flats.
引用
收藏
页码:62 / 78
页数:17
相关论文
共 50 条
  • [21] Ritchey-Common sparse-aperture testing of the Giant Steerable Science Mirror
    An, Qichang
    Zhang, Jingxu
    Yang, Fei
    Zhao, Hongchao
    Cao, Haifeng
    APPLIED OPTICS, 2018, 57 (27) : 7764 - 7769
  • [22] Bayesian Estimation of Single-Test Reliability Coefficients
    Pfadt, Julius M.
    van den Bergh, Don
    Sijtsma, Klaas
    Moshagen, Morten
    Wagenmakers, Eric-Jan
    MULTIVARIATE BEHAVIORAL RESEARCH, 2022, 57 (04) : 620 - 641
  • [23] A tutorial on Bayesian single-test reliability analysis with JASP
    Pfadt, Julius M.
    van den Bergh, Don
    Sijtsma, Klaas
    Wagenmakers, Eric-Jan
    BEHAVIOR RESEARCH METHODS, 2023, 55 (03) : 1069 - 1078
  • [24] Single-test parallel assessment of multiple genetic disorders
    Tavares, Purificacao
    Dias, Luis
    Palmeiro, Aida
    Rendeiro, Paula
    Tolias, Peter
    PERSONALIZED MEDICINE, 2011, 8 (03) : 375 - 379
  • [25] A tutorial on Bayesian single-test reliability analysis with JASP
    Julius M. Pfadt
    Don van den Bergh
    Klaas Sijtsma
    Eric-Jan Wagenmakers
    Behavior Research Methods, 2023, 55 : 1069 - 1078
  • [26] Single-test syphilis serology: A case of not seeing the forest for the trees
    Zulu, Ethan Mabvuto
    Herlihy, Julie M.
    Duffy, Cassandra R.
    Mwananyanda, Lawrence
    Chilengi, Roma
    Forman, Leah
    Heeren, Tim
    Gill, Christopher J.
    Chavuma, Roy
    Payne-Lohman, Barbara
    Thea, Donald M.
    PLOS ONE, 2024, 19 (05):
  • [27] Single-test evaluation of directional elastic properties of anisotropic structured materials
    Boddapati, Jagannadh
    Flaschel, Moritz
    Kumar, Siddhant
    De Lorenzis, Laura
    Daraio, Chiara
    JOURNAL OF THE MECHANICS AND PHYSICS OF SOLIDS, 2023, 181
  • [28] Harmonized molecular classification; assessment of a single-test ProMisE NGS tool
    Jamieson, Amy
    McConechy, Melissa K.
    Lum, Amy
    Leung, Samuel
    Thompson, Emily F.
    Senz, Janine
    Talhouk, Aline
    Huntsman, David G.
    Bashashati, Ali
    Gilks, C. Blake
    McAlpine, Jessica N.
    GYNECOLOGIC ONCOLOGY, 2023, 175 : 45 - 52
  • [29] Local adaptation or foreign advantage? Effective use of a single-test site common garden to evaluate adaptation across ecological scales
    von Wettberg, Eric J. B.
    Marques, Edward
    Murren, Courtney J.
    NEW PHYTOLOGIST, 2016, 211 (01) : 8 - 10
  • [30] POWDER-FORMULATED, SINGLE-TEST EMIT QST ASSAYS FOR CARBAMAZEPINE, ETHOSUXIMIDE, AND PRIMIDONE
    CROMPTON, RM
    CERELLI, MJ
    FULTZ, TJ
    HSU, E
    VALDEZ, J
    CENTOFANTI, JM
    CLINICAL CHEMISTRY, 1986, 32 (06) : 1079 - 1080