Single-test Ritchey-Common interferometry

被引:0
|
作者
Liu, Yiming [1 ]
Xu, Chuheng [1 ]
Hu, Yao [1 ]
Lu, Huiqin [2 ]
Li, Jinpeng [2 ]
Wu, Tiancheng [2 ]
Zhang, Shaohui [1 ]
Chang, Xu [3 ]
Hao, Qun [1 ]
机构
[1] Beijing Inst Technol, Sch Opt & Photon, Beijing Key Lab Precis Optoelect Measurement Instr, Beijing 100081, Peoples R China
[2] Chinese Acad Sci, Nanjing Astron Instruments Co Ltd, Nanjing 210042, Jiangsu, Peoples R China
[3] Natl Inst Metrol, Beijing, Peoples R China
基金
中国国家自然科学基金;
关键词
LARGE OPTICS; TELESCOPE;
D O I
10.1364/OE.505632
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
The Ritchey-Common test is widely adopted to measure large optical flats. The traditional Ritchey-Common test eliminates the defocus error with multiple tests by changing the position of the mirrors, which suffers from cumbersome steps, poor repeatability, coupled system error, extra mirror deformation, and potential overturning. The above problems increase the test time, decrease the reliability and accuracy, increase the test cost, and threaten manufacturing safety. We propose a single-test Ritchey-Common interferometry to avoid the obligatory position change in the traditional method. A sub-aperture of test flat is directly measured by a small-aperture interferometer before the test, which is easy to implement, to replace the extra system wavefront measurement in different positions. The defocus is calculated in sub-aperture at exactly the same position as the full-field measurement without the position change, then the surface form under test can be obtained with accurate optical path modeling. Measurement experiments for 100 mm and 2050 mm aperture flats were performed to demonstrate the feasibility of this method. Compared with a direct test in a standard Zygo interferometer, the peak to valley (PV) and root mean square (RMS) errors were 0.0889 ? and 0.0126 ? (?=632.8 nm), respectively, which reaches the upper limit of accuracy of the interferometer. To the best of our knowledge, this is the first proposal of the Ritchey-Common test that can eliminate the defocus error and realize high accuracy measurement in a single test. Our work paves the way for reliable and practical optical metrology for large optical flats.
引用
收藏
页码:62 / 78
页数:17
相关论文
共 50 条
  • [41] Validity of a Novel Point-of-Care Troponin Assay for Single-Test Rule-Out of Acute Myocardial Infarction Reply
    Pickering, John W.
    Young, Joanna M.
    Than, Martin P.
    JAMA CARDIOLOGY, 2019, 4 (03) : 298 - 299
  • [42] Analysis and verification for accuracy of Ritchey angle in flat mirror test
    Zhang, X. (zhangxiaohui0123@163.com), 1600, Chinese Optical Society (33):
  • [43] Real world performance of a single-test next generation sequencing (NGS) endometrial cancer molecular classification tool in clinical practice
    Jamieson, Amy
    Lum, Amy
    Leung, Samuel
    Chiu, Derek
    Lapuk, Anna
    Huntsman, David
    Gilks, Blake
    Mcalpine, Jessica
    INTERNATIONAL JOURNAL OF GYNECOLOGICAL CANCER, 2024, 34 (SUPPL_3) : A150 - A151
  • [44] Determination of a whole-blood single-test low-risk threshold for a point-of-care high-sensitivity troponin assay
    Pickering, John W.
    Hamill, Laura
    Aldous, Sally
    Joyce, Laura
    Stothart, R. Alex
    Williams, Otis
    Florkowski, Christopher M.
    Than, Martin
    EMERGENCY MEDICINE JOURNAL, 2024, 41 (05) : 322 - 323
  • [45] Targeted exome sequencing designed for blood group, platelet, and neutrophil antigen investigations: Proof-of-principle study for a customized single-test system
    Roulis, Eileen
    Schoeman, Elizna
    Hobbs, Matthew
    Jones, Greg
    Burton, Mark
    Pahn, Gail
    Liew, Yew-Wah
    Flower, Robert
    Hyland, Catherine
    TRANSFUSION, 2020, 60 (09) : 2108 - 2120
  • [46] Efficacy of a single diagnostic test for sensitization to common inhalant allergens
    Williams, PB
    Siegel, C
    Portnoy, J
    ANNALS OF ALLERGY ASTHMA & IMMUNOLOGY, 2001, 86 (02) : 196 - 202
  • [47] The Validity of Screening For Open-angle Glaucoma in High-risk Populations With Single-test Screening Mode Frequency Doubling Technology Perimetry (FDT)
    Fansi, Alvine A. Kamdeu
    Li, Gisele
    Harasymowycz, Paul J.
    JOURNAL OF GLAUCOMA, 2011, 20 (03) : 167 - 171
  • [48] Common-path spectral interferometry for single-shot terahertz electro-optics detection
    Zheng, Shuiqin
    Pan, Xinjian
    Cai, Yi
    Lin, Qinggang
    Li, Ying
    Xu, Shixiang
    Li, Jingzhen
    Fan, Dianyuan
    OPTICS LETTERS, 2017, 42 (21) : 4263 - 4266
  • [49] An experimental proposal to test dynamic quantum non-locality with single-atom interferometry
    Zhu, Shi-Liang
    Xue, Zheng-Yuan
    Zhang, Dan-Wei
    Duan, Lu-Ming
    EPL, 2011, 94 (05)
  • [50] INFRARED INTERFEROMETRY WITH SINGLE TELESCOPES
    CHELLI, A
    ASTROPHYSICS AND SPACE SCIENCE, 1989, 160 (1-2) : 369 - 371