Single-test Ritchey-Common interferometry

被引:0
|
作者
Liu, Yiming [1 ]
Xu, Chuheng [1 ]
Hu, Yao [1 ]
Lu, Huiqin [2 ]
Li, Jinpeng [2 ]
Wu, Tiancheng [2 ]
Zhang, Shaohui [1 ]
Chang, Xu [3 ]
Hao, Qun [1 ]
机构
[1] Beijing Inst Technol, Sch Opt & Photon, Beijing Key Lab Precis Optoelect Measurement Instr, Beijing 100081, Peoples R China
[2] Chinese Acad Sci, Nanjing Astron Instruments Co Ltd, Nanjing 210042, Jiangsu, Peoples R China
[3] Natl Inst Metrol, Beijing, Peoples R China
基金
中国国家自然科学基金;
关键词
LARGE OPTICS; TELESCOPE;
D O I
10.1364/OE.505632
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
The Ritchey-Common test is widely adopted to measure large optical flats. The traditional Ritchey-Common test eliminates the defocus error with multiple tests by changing the position of the mirrors, which suffers from cumbersome steps, poor repeatability, coupled system error, extra mirror deformation, and potential overturning. The above problems increase the test time, decrease the reliability and accuracy, increase the test cost, and threaten manufacturing safety. We propose a single-test Ritchey-Common interferometry to avoid the obligatory position change in the traditional method. A sub-aperture of test flat is directly measured by a small-aperture interferometer before the test, which is easy to implement, to replace the extra system wavefront measurement in different positions. The defocus is calculated in sub-aperture at exactly the same position as the full-field measurement without the position change, then the surface form under test can be obtained with accurate optical path modeling. Measurement experiments for 100 mm and 2050 mm aperture flats were performed to demonstrate the feasibility of this method. Compared with a direct test in a standard Zygo interferometer, the peak to valley (PV) and root mean square (RMS) errors were 0.0889 ? and 0.0126 ? (?=632.8 nm), respectively, which reaches the upper limit of accuracy of the interferometer. To the best of our knowledge, this is the first proposal of the Ritchey-Common test that can eliminate the defocus error and realize high accuracy measurement in a single test. Our work paves the way for reliable and practical optical metrology for large optical flats.
引用
收藏
页码:62 / 78
页数:17
相关论文
共 50 条
  • [31] Beyond alpha and omega: The accuracy of single-test reliability estimators in unidimensional continuous data
    Cho, Eunseong
    BEHAVIOR RESEARCH METHODS, 2024, 56 (06) : 6299 - 6317
  • [32] Validation of promise NGS; a single-test DNA-based endometrial cancer molecular classifier
    Jamieson, Amy
    Grube, Marcel
    Kommoss, Felix
    Heitz, Florian
    Heublein, Sabine
    Zeimet, Alain
    Hasenburg, Annette
    Diebold, Joachim
    Walter, Christina Barbara
    Staebler, Annette
    Lum, Amy
    Leung, Samuel
    Chiu, Derek
    Reynolds, Jerian
    Mcconechy, Melissa
    Huntsman, David
    Gilks, Blake
    Kommoss, Stefan
    Mcalpine, Jessica
    INTERNATIONAL JOURNAL OF GYNECOLOGICAL CANCER, 2024, 34 (SUPPL_3) : A151 - A152
  • [33] Diagnosing Gestational Diabetes by a Single-Test Procedure Is a Propitious Step Towards Containing the Epidemic of Diabetes
    Seshiah, V
    Balaji, Vijayam
    Bronson, Stephen C.
    Jain, Rajesh
    Chandrasekar, Anjalakshi
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2021, 13 (11)
  • [34] An evaluation of the single-test tension infiltrometer method for determining the hydraulic conductivity of lateral capillarity domain soils
    Bagarello, V
    Ferraris, S
    Iovino, M
    BIOSYSTEMS ENGINEERING, 2004, 87 (02) : 247 - 255
  • [35] Single-test determination of the friction coefficient and stress-strain curve for application in metal-forming analyses
    Marcon, AF
    Bittencourt, E
    Creus, GJ
    EXPERIMENTAL MECHANICS, 2000, 40 (02) : 124 - 128
  • [36] POWDER-FORMULATED, SINGLE-TEST EMIT QST ASSAYS FOR ACETAMINOPHEN, AMIKACIN, N-ACETYLPROCAINAMIDE, AND PROCAINAMIDE
    CROMPTON, RM
    SCOVILL, DM
    LAM, X
    BROWN, L
    PETRICH, DE
    VALDEZ, J
    CENTOFANTI, JM
    CLINICAL CHEMISTRY, 1985, 31 (06) : 943 - 943
  • [37] Single-test determination of the friction coefficient and stress-strain curve for application in metal-forming analyses
    A. F. Marcon
    E. Bittencourt
    G. J. Creus
    Experimental Mechanics, 2000, 40 : 124 - 128
  • [38] Validity of a Novel Point-of-Care Troponin Assay for Single-Test Rule-Out of Acute Myocardial Infarction
    Pickering, John W.
    Young, Joanna M.
    George, Peter M.
    Watson, Antony S.
    Aldous, Sally J.
    Troughton, Richard W.
    Pemberton, Christopher J.
    Richards, A. Mark
    Cullen, Louise A.
    Than, Martin R.
    JAMA CARDIOLOGY, 2018, 3 (11) : 1108 - 1112
  • [39] INTER-LABORATORY COMPARISON STUDY OF THE TECHNICON-TM STAC-TM SINGLE-TEST ANALYZER WITH COMPUTER
    PAQUET, RJ
    LEVINE, JB
    CLINICAL CHEMISTRY, 1979, 25 (06) : 1116 - 1116
  • [40] COMMON PATH INTERFEROMETRY
    AUGUSTYN, WH
    OPTICAL ENGINEERING, 1973, 12 (05) : 180 - 181