Ritchey-Common sparse-aperture testing of the Giant Steerable Science Mirror

被引:7
|
作者
An, Qichang [1 ,2 ]
Zhang, Jingxu [1 ]
Yang, Fei [1 ]
Zhao, Hongchao [1 ]
Cao, Haifeng [1 ,2 ]
机构
[1] Chinese Acad Sci, Changchun Inst Opt Fine Mech & Phys, Changchun 130033, Jilin, Peoples R China
[2] Grad Univ Chinese Acad Sci, Beijing 100039, Peoples R China
基金
国家重点研发计划; 中国国家自然科学基金;
关键词
POINT-SOURCE SENSITIVITY; LARGE TELESCOPES; STITCHING TEST; ERROR; CALIBRATION;
D O I
10.1364/AO.57.007764
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
The Giant Steerable Science Mirror (GSSM) is the tertiary mirror of the future large telescope, the Thirty Meter Telescope. However, the mirror is too large to be tested using only one aperture, and using many apertures will increase the cost of testing. To accomplish testing at a low cost, the number of apertures should be reduced. The Ritchey-Common (R-C) testing method, commonly used for testing large flat surfaces, uses only a reference spherical mirror and avoids the use of large planar interferometers. Additionally, only the low-spatial-frequency mirror figure is relevant in the system assembly and alignment. Hence, the applicability of sparse-aperture testing is investigated in this paper. Sparse-aperture testing and the R-C method were combined to lower the cost. Using this method and the normalized point source sensitivity (PSSn), the mirror figure can be specified in a simple and accurate manner. Moreover, as fewer subapertures are under test, the efficiency can be improved. An error analysis is conducted, focusing on the shifting error, irregularity error, tipping error, tangential/sagittal error, and seeing. For the testing of the GSSM prototype, the error analysis showed the total error in PSSn is 0.9701. (C) 2018 Optical Society of America
引用
收藏
页码:7764 / 7769
页数:6
相关论文
共 18 条
  • [1] Local Sampling Ritchey-Common Test for Large Aperture Flat Mirror
    Lin Dongdong
    Hu Mingyong
    Li Jinpeng
    Ding Yaofang
    [J]. LASER & OPTOELECTRONICS PROGRESS, 2018, 55 (03)
  • [2] The error analyze of testing the large aperture flat by the Ritchey-Common method
    Ji, Bo
    Xu, Chen
    Li, Bo
    [J]. INTERNATIONAL SYMPOSIUM ON OPTOELECTRONIC TECHNOLOGY AND APPLICATION 2014: IMAGING SPECTROSCOPY; AND TELESCOPES AND LARGE OPTICS, 2014, 9298
  • [3] Study on test the large aperture flat by a smaller standard mirror use the Ritchey-Common method
    Bo, Ji
    Chen, Xu
    [J]. PROCEEDINGS OF THE 2014 9TH IEEE CONFERENCE ON INDUSTRIAL ELECTRONICS AND APPLICATIONS (ICIEA), 2014, : 258 - 261
  • [4] Ritchey-Common test for a 1.5 m-diameter flat mirror
    Zhu, S.
    Zhang, X. H.
    [J]. JOURNAL OF THE EUROPEAN OPTICAL SOCIETY-RAPID PUBLICATIONS, 2014, 9 : 1 - 5
  • [5] Simulation test research of using the Ritchey-Common method for the detection of large flat mirror
    Zhu, Shuo
    Zhang, Xiaohui
    [J]. FRONTIERS OF ADVANCED MATERIALS AND ENGINEERING TECHNOLOGY, PTS 1-3, 2012, 430-432 : 1733 - 1737
  • [6] Testing large plane mirrors with the Ritchey-Common test in two angular positions
    Dörband, B
    Schulte, S
    Schillke, F
    Wiedmann, W
    [J]. OPTICAL FABRICATION AND TESTING, 1999, 3739 : 330 - 334
  • [7] Pre-Construction of Giant Steerable Science Mirror for TMT
    Yang Fei
    Zhao Hongchao
    Guo Peng
    An Qichang
    Jiang Haibo
    [J]. OPTOMECHANICAL ENGINEERING 2015, 2015, 9573
  • [8] Giant Science Steering Mirror Prototype Sub-aperture Testing Error Analysis
    An Qi-chang
    Zhang Jing-xu
    Yang Fei
    Zhao Hong-chao
    [J]. ACTA PHOTONICA SINICA, 2018, 47 (01)
  • [9] Pre-Construction Progress of Giant Steerable Science Mirror for TMT
    Yang Fei
    Zhao Hongchao
    An Qichang
    Guo Peng
    Jiang Haibo
    Han Linchu
    Ford, Virginia
    Cole, Glen
    Smith, Byron
    Campbell, Marvin
    [J]. GROUND-BASED AND AIRBORNE TELESCOPES VI, 2016, 9906
  • [10] Conceptual Design of Giant Steerable Science Mirror Cell Assembly for TMT
    Yang Fei
    Liu Guo-jun
    Zhao Hong-chao
    Guo Peng
    An Qi-chang
    Jiang Hai-bo
    Yang Fei
    [J]. 2015 INTERNATIONAL CONFERENCE ON OPTOELECTRONICS AND MICROELECTRONICS (ICOM), 2015, : 211 - 216