Clinical benchmarking of a commercial software for skin dose estimation in cardiac, abdominal, and neurology interventional procedures

被引:0
|
作者
Hadid-Beurrier, Lama [1 ]
Geryes, Bouchra Habib [2 ,5 ]
Jean-Pierre, Antonella [1 ]
Gaudin, Paul-Adrien [3 ]
Feghali, Joelle Ann [4 ]
机构
[1] Lariboisiere Univ Hosp, APHP, Med Phys & Radiat Protect Dept, Paris, France
[2] Necker Enfants Malades Univ Hosp, APHP, Radiol Dept, Paris, France
[3] Hop Fernand Widal, URC Lariboisiere St Louis, Paris, France
[4] APHP Bicetre, Radiol Dept, Paris, France
[5] Necker Enfants Malades Univ Hosp, AP HP, 149 Rue Sevres, F-75743 Paris 15, France
关键词
film dosimetry; fluoroscopy; interventional; radiology; CARDIOLOGY; FILMS; VALIDATION; RADIOLOGY; SYSTEMS;
D O I
10.1002/mp.16956
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background: Radiation exposure from interventional radiology (IR) could lead to potential risk of skin injury in patients. Several dose monitoring software like radiation dose monitor (RDM) were developed to estimate the patient skin dose (PSD) distribution in IR. Purpose: This study benchmarked the accuracy of RDM software in estimating PSD as compared to GafChromic film baseline in-vivo measurements on patients during cardiac, abdominal, and neurology IR procedures. Methods: The prospective study conducted in four IR departments included 81 IR procedures (25 cardiac, 31 abdominal, and 25 neurology procedures) on three angiographic systems. PSD and field geometry were measured by placing GafChromic film under the patient's back. Statistical analyses were performed to compare the software estimation and film measurement results in terms of PSD and geometric accuracy. Results: Median values of measured/calculated PSD were 1140/1005, 591/655.9, and 538/409.7 mGy for neurology, cardiac, and abdominal procedures, respectively. For all angiographic systems, the median (InterQuartile Range, IQR) difference between calculated and measured PSD was -10.2% (-21.8%-5.7%) for neurology, -4.5% (-19.5%-15.5%) for cardiac, and -21.9% (-38.7%--3.6%) for abdominal IR procedures. These differences were not significant for all procedures (p > 0.05). Discrepancies increased up to -82% in lower dose regions where the measurement uncertainties are higher. Regarding the geometric accuracy, RDM correctly reproduced the skin dose map and estimated PSD area dimensions closely matched those registered on films with a median (IQR) difference of 0 cm (-1-0.8 cm). Conclusions: RDM is proved to be a useful solution for the estimation of PSD and skin dose distribution during abdominal, cardiac and neurology IR procedures despite a geometry phantom which is not specific to the latter type of IR procedures.
引用
收藏
页码:3687 / 3697
页数:11
相关论文
共 50 条
  • [1] On skin dose estimation software in interventional radiology
    Colombo, P. E.
    Felisi, M.
    Riga, S.
    Torresin, A.
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2021, 81 : 182 - 184
  • [2] ESTIMATION OF PEAK SKIN DOSE IN INTERVENTIONAL CARDIOLOGY PROCEDURES
    Saaring, Juhan
    Kepler, Kalle
    MEDICAL PHYSICS IN THE BALTIC STATES, 2015, : 43 - 47
  • [3] BENCHMARKING THE DOSE MAP SOFTWARE FOR CLINICAL IMPLEMENTATION AND ESTABLISHMENT OF A LOCAL FOLLOW-UP PROTOCOL FOR THE MANAGEMENT OF SKIN INJURES FOLLOWING COMPLEX INTERVENTIONAL CARDIOLOGY PROCEDURES
    Rizk, Chadia
    Sarkis, Antoine
    Bejjani, Alice
    Dabin, Jeremie
    Farah, Jad
    RADIATION PROTECTION DOSIMETRY, 2020, 190 (04) : 392 - 399
  • [4] Medical staff dose estimation during pediatric cardiac interventional procedures
    Roberto, Maryanna Regina
    Leite, Luiz M. A.
    Cruz, Aricia R. P.
    Khoury, Helen
    de Barros, Vinicius S. M.
    Neves, Juliana R.
    Cartaxo, Jessica M.
    Ubeda, Carlos
    Asfora, Viviane K.
    JOURNAL OF RADIOLOGICAL PROTECTION, 2024, 44 (02)
  • [5] Comparison of four analogues of radiation dose for estimation of skin dose during interventional radiology procedures
    Fletcher, DW
    Miller, DM
    Balter, S
    Taylor, MA
    RADIOLOGY, 2000, 217 : 403 - 404
  • [6] Patient skin dose in cardiac interventional procedures: Conventional fluoroscopy versus pulsed fluoroscopy
    Chida, Koichi
    Fuda, Kenji
    Saito, Haruo
    Takai, Yoshihiro
    Takahashi, Shoki
    Yamada, Shogo
    Kohzuki, Masahiro
    Zuguchi, Masayuki
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2007, 69 (01) : 115 - 121
  • [7] Relationships between entrance skin dose, effective dose and dose area product for patients in diagnostic and interventional cardiac procedures
    Hansson, B
    Karambatsakidou, A
    RADIATION PROTECTION DOSIMETRY, 2000, 90 (1-2) : 141 - 144
  • [8] Does digital acquisition reduce patients' skin dose in cardiac interventional procedures? An experimental study
    Chida, K
    Saito, H
    Zuguchi, M
    Shirotori, K
    Kumagai, S
    Nakayama, H
    Matsubara, K
    Kohzuki, M
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2004, 183 (04) : 1111 - 1114
  • [9] Dose to cardiologists in haemodynamic and electrophysiology cardiac interventional procedures
    Trianni, A
    Padovani, R
    Foti, C
    Cragnolini, E
    Chizzola, G
    Toh, H
    Bernardi, G
    Proclemer, A
    RADIATION PROTECTION DOSIMETRY, 2005, 117 (1-3) : 111 - 115
  • [10] Dose estimation of eye lens for interventional procedures in diagnosis
    Liu, Yu-Rong
    Huang, Chia-Yu
    Hsu, Ching-Han
    Hsu, Fang-Yuh
    RADIATION PHYSICS AND CHEMISTRY, 2017, 140 : 247 - 251