ESTIMATION OF PEAK SKIN DOSE IN INTERVENTIONAL CARDIOLOGY PROCEDURES

被引:0
|
作者
Saaring, Juhan [1 ]
Kepler, Kalle [2 ]
机构
[1] Tartu Univ Hosp, Tartu, Estonia
[2] Univ Tartu, EE-50090 Tartu, Estonia
关键词
peak skin dose; patient dose; interventional cardiology; angiography;
D O I
暂无
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
A method for post-procedural peak skin dose (PSD) estimation was developed, using dose reports provided by the angiography device and pre-recorded dosimetric characteristics. A study was conducted to implement the developed method. Dose reports of 20 consecutive coronary angiography (CA) and percutaneous coronary transluminal angioplasty (PTCA) procedures performed on two different angiography devices were collected. The results were used to set local reference values and to provide local equations for PSD calculation from other dosimetric quantities.
引用
收藏
页码:43 / 47
页数:5
相关论文
共 50 条
  • [1] Skin dose and dose-area product values for interventional cardiology procedures
    Vano, E
    Gonzalez, L
    Ten, JI
    Fernandez, JM
    Guibelalde, E
    Macaya, C
    BRITISH JOURNAL OF RADIOLOGY, 2001, 74 (877): : 48 - 55
  • [2] A Direct Estimate of Peak Skin Dose for Interventional Fluoroscopy Procedures
    Weir, V.
    Zhang, J.
    MEDICAL PHYSICS, 2016, 43 (06) : 3368 - 3368
  • [3] How Useful Are Indirect Dose Metrics for Estimating Peak Skin Dose in Interventional Cardiology?
    Jones, A.
    Pasciak, A.
    MEDICAL PHYSICS, 2016, 43 (06) : 3749 - 3749
  • [4] Patient's Peak Skin Dose evaluation using Gafchromic films in interventional cardiology procedures and its correlation with other dose indicators
    Pasquino, M.
    Cutaia, C.
    Poli, M.
    Valero, C.
    Peroni, G.
    De Benedictis, M.
    Petrucci, E.
    Stasi, M.
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2018, 53 : 103 - 107
  • [5] Occupational eye dose in interventional cardiology procedures
    Haga, Yoshihiro
    Chida, Koichi
    Kaga, Yuji
    Sota, Masahiro
    Meguro, Taiichiro
    Zuguchi, Masayuki
    SCIENTIFIC REPORTS, 2017, 7
  • [6] ASSESSMENT OF PATIENT'S PEAK SKIN DOSE USING GAFCHROMIC FILMS DURING INTERVENTIONAL CARDIOLOGY PROCEDURES: ROUTINE EXPERIENCE FEEDBACK
    Greffier, J.
    Moliner, G.
    Pereira, F.
    Cornillet, L.
    Ledermann, B.
    Schmutz, L.
    Lomma, M.
    Cayla, G.
    Beregi, J. P.
    RADIATION PROTECTION DOSIMETRY, 2017, 174 (03) : 395 - 405
  • [7] Occupational eye dose in interventional cardiology procedures
    Yoshihiro Haga
    Koichi Chida
    Yuji Kaga
    Masahiro Sota
    Taiichiro Meguro
    Masayuki Zuguchi
    Scientific Reports, 7
  • [8] C-arm rotation as a method for reducing peak skin dose in interventional cardiology
    Pasciak, Alexander S.
    Bourgeois, Austin C.
    Jones, A. Kyle
    OPEN HEART, 2014, 1 (01):
  • [9] A study of the relationship between peak skin dose and cumulative air kerma in interventional neuroradiology and cardiology
    Neil, S.
    Padgham, C.
    Martin, C. J.
    JOURNAL OF RADIOLOGICAL PROTECTION, 2010, 30 (04) : 659 - 672
  • [10] How Does C-Arm Rotation Affect Peak Skin Dose in Interventional Cardiology?
    Pasciak, A.
    Jones, A.
    MEDICAL PHYSICS, 2013, 40 (06)