Clinical benchmarking of a commercial software for skin dose estimation in cardiac, abdominal, and neurology interventional procedures

被引:0
|
作者
Hadid-Beurrier, Lama [1 ]
Geryes, Bouchra Habib [2 ,5 ]
Jean-Pierre, Antonella [1 ]
Gaudin, Paul-Adrien [3 ]
Feghali, Joelle Ann [4 ]
机构
[1] Lariboisiere Univ Hosp, APHP, Med Phys & Radiat Protect Dept, Paris, France
[2] Necker Enfants Malades Univ Hosp, APHP, Radiol Dept, Paris, France
[3] Hop Fernand Widal, URC Lariboisiere St Louis, Paris, France
[4] APHP Bicetre, Radiol Dept, Paris, France
[5] Necker Enfants Malades Univ Hosp, AP HP, 149 Rue Sevres, F-75743 Paris 15, France
关键词
film dosimetry; fluoroscopy; interventional; radiology; CARDIOLOGY; FILMS; VALIDATION; RADIOLOGY; SYSTEMS;
D O I
10.1002/mp.16956
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background: Radiation exposure from interventional radiology (IR) could lead to potential risk of skin injury in patients. Several dose monitoring software like radiation dose monitor (RDM) were developed to estimate the patient skin dose (PSD) distribution in IR. Purpose: This study benchmarked the accuracy of RDM software in estimating PSD as compared to GafChromic film baseline in-vivo measurements on patients during cardiac, abdominal, and neurology IR procedures. Methods: The prospective study conducted in four IR departments included 81 IR procedures (25 cardiac, 31 abdominal, and 25 neurology procedures) on three angiographic systems. PSD and field geometry were measured by placing GafChromic film under the patient's back. Statistical analyses were performed to compare the software estimation and film measurement results in terms of PSD and geometric accuracy. Results: Median values of measured/calculated PSD were 1140/1005, 591/655.9, and 538/409.7 mGy for neurology, cardiac, and abdominal procedures, respectively. For all angiographic systems, the median (InterQuartile Range, IQR) difference between calculated and measured PSD was -10.2% (-21.8%-5.7%) for neurology, -4.5% (-19.5%-15.5%) for cardiac, and -21.9% (-38.7%--3.6%) for abdominal IR procedures. These differences were not significant for all procedures (p > 0.05). Discrepancies increased up to -82% in lower dose regions where the measurement uncertainties are higher. Regarding the geometric accuracy, RDM correctly reproduced the skin dose map and estimated PSD area dimensions closely matched those registered on films with a median (IQR) difference of 0 cm (-1-0.8 cm). Conclusions: RDM is proved to be a useful solution for the estimation of PSD and skin dose distribution during abdominal, cardiac and neurology IR procedures despite a geometry phantom which is not specific to the latter type of IR procedures.
引用
收藏
页码:3687 / 3697
页数:11
相关论文
共 50 条
  • [31] Main clinical, therapeutic and technical factors related to patient's maximum skin dose in interventional cardiology procedures
    Journy, N.
    Sinno-Tellier, S.
    Maccia, C.
    Le Tertre, A.
    Pirard, P.
    Pages, P.
    Eilstein, D.
    Donadieu, J.
    Bar, O.
    BRITISH JOURNAL OF RADIOLOGY, 2012, 85 (1012): : 433 - 442
  • [32] Assessment of maximum entrance skin dose of patients undergoing cardiac interventional procedures and its correlation with other dosimetric parameters
    Toossi M.T.B.
    Khosroabadi M.
    Mehrpouyan M.
    Moghaddam H.R.
    Iranian Journal of Medical Physics, 2020, 17 (04) : 235 - 246
  • [33] Entrance skin dose measured with MOSFETs in children undergoing interventional radiology procedures
    Diana Glennie
    Bairbre L. Connolly
    Christopher Gordon
    Pediatric Radiology, 2008, 38 : 1180 - 1187
  • [34] Entrances skin dose distribution maps for interventional neuroradiological procedures: A preliminary study
    Rampado, O
    Ropolo, R
    RADIATION PROTECTION DOSIMETRY, 2005, 117 (1-3) : 256 - 259
  • [35] Entrance skin dose measured with MOSFETs in children undergoing interventional radiology procedures
    Glennie, Diana
    Connolly, Bairbre L.
    Gordon, Christopher
    PEDIATRIC RADIOLOGY, 2008, 38 (11) : 1180 - 1187
  • [36] Skin dose measurement for patients using imaging plates in interventional radiology procedures
    Ohuchi, Hiroko
    Satoh, Toshimitsu
    Eguchi, Yoichi
    Kaga, Yuji
    Arai, Takeshi
    Suzuki, Shin-ichi
    Yamadera, Akira
    HEALTH PHYSICS, 2007, 93 (01): : 78 - 86
  • [37] Estimating the maximum radiation skin dose during cardiac interventional procedures using the dose- area product, fluoroscopic time, and patient weight
    Chida, K.
    Saito, H.
    Otani, H.
    Zuguchi, M.
    Shimura, H.
    Nakada, M.
    Takahashi, S.
    Shirato, K.
    EUROPEAN HEART JOURNAL, 2005, 26 : 694 - 694
  • [38] Patient skin dose assessment during CT-guided interventional procedures
    Tsapaki, V.
    Triantopoulou, C.
    Maniatis, P.
    Kottou, S.
    Tsalafoutas, J.
    Papailiou, J.
    RADIATION PROTECTION DOSIMETRY, 2008, 129 (1-3) : 29 - 31
  • [39] RELATIONSHIPS BETWEEN ENTRANCE SKIN DOSE, EFFECTIVE DOSE AND DOSE AREA PRODUCT FOR PATIENTS IN DIAGNOSTIC AND INTERVENTIONAL CARDIAC PROCEDURES (vol 90, pg 141, 2000)
    Hansson, B.
    Karambatsakidou, A.
    RADIATION PROTECTION DOSIMETRY, 2018, 178 (03) : 341 - 341
  • [40] Practical guidelines for personal monitoring and estimation of effective dose and dose to the lens of the eye in interventional procedures
    Askounis, Panagiotis
    Gonzalez, Anna Torras
    Ginjaume, Merce
    Carinou, Eleftheria
    JOURNAL OF RADIOLOGICAL PROTECTION, 2022, 42 (03)