Clinical benchmarking of a commercial software for skin dose estimation in cardiac, abdominal, and neurology interventional procedures

被引:0
|
作者
Hadid-Beurrier, Lama [1 ]
Geryes, Bouchra Habib [2 ,5 ]
Jean-Pierre, Antonella [1 ]
Gaudin, Paul-Adrien [3 ]
Feghali, Joelle Ann [4 ]
机构
[1] Lariboisiere Univ Hosp, APHP, Med Phys & Radiat Protect Dept, Paris, France
[2] Necker Enfants Malades Univ Hosp, APHP, Radiol Dept, Paris, France
[3] Hop Fernand Widal, URC Lariboisiere St Louis, Paris, France
[4] APHP Bicetre, Radiol Dept, Paris, France
[5] Necker Enfants Malades Univ Hosp, AP HP, 149 Rue Sevres, F-75743 Paris 15, France
关键词
film dosimetry; fluoroscopy; interventional; radiology; CARDIOLOGY; FILMS; VALIDATION; RADIOLOGY; SYSTEMS;
D O I
10.1002/mp.16956
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background: Radiation exposure from interventional radiology (IR) could lead to potential risk of skin injury in patients. Several dose monitoring software like radiation dose monitor (RDM) were developed to estimate the patient skin dose (PSD) distribution in IR. Purpose: This study benchmarked the accuracy of RDM software in estimating PSD as compared to GafChromic film baseline in-vivo measurements on patients during cardiac, abdominal, and neurology IR procedures. Methods: The prospective study conducted in four IR departments included 81 IR procedures (25 cardiac, 31 abdominal, and 25 neurology procedures) on three angiographic systems. PSD and field geometry were measured by placing GafChromic film under the patient's back. Statistical analyses were performed to compare the software estimation and film measurement results in terms of PSD and geometric accuracy. Results: Median values of measured/calculated PSD were 1140/1005, 591/655.9, and 538/409.7 mGy for neurology, cardiac, and abdominal procedures, respectively. For all angiographic systems, the median (InterQuartile Range, IQR) difference between calculated and measured PSD was -10.2% (-21.8%-5.7%) for neurology, -4.5% (-19.5%-15.5%) for cardiac, and -21.9% (-38.7%--3.6%) for abdominal IR procedures. These differences were not significant for all procedures (p > 0.05). Discrepancies increased up to -82% in lower dose regions where the measurement uncertainties are higher. Regarding the geometric accuracy, RDM correctly reproduced the skin dose map and estimated PSD area dimensions closely matched those registered on films with a median (IQR) difference of 0 cm (-1-0.8 cm). Conclusions: RDM is proved to be a useful solution for the estimation of PSD and skin dose distribution during abdominal, cardiac and neurology IR procedures despite a geometry phantom which is not specific to the latter type of IR procedures.
引用
收藏
页码:3687 / 3697
页数:11
相关论文
共 50 条
  • [41] Practical dose reduction tips for abdominal interventional procedures using CT-guidance
    Lamba, Ramit
    Corwin, Michael T.
    Fananapazir, Ghaneh
    ABDOMINAL RADIOLOGY, 2016, 41 (04) : 743 - 753
  • [42] Practical dose reduction tips for abdominal interventional procedures using CT-guidance
    Ramit Lamba
    Michael T. Corwin
    Ghaneh Fananapazir
    Abdominal Radiology, 2016, 41 : 743 - 753
  • [43] Interventional cardiologist skin radiation during cardiac catheterizations and therapeutic procedures.
    Gaxiola, E
    Nájar, S
    Uribe, J
    Rentería, R
    Briseño, H
    De la Peña, G
    Román, L
    Cordero, A
    Flores, JA
    Sánchez, S
    Inzunza, G
    AMERICAN JOURNAL OF CARDIOLOGY, 2001, 88 (5A): : 125G - 125G
  • [44] Analysis of dose-related data logged for fluoroscopic cardiac interventional procedures
    Dohatcu, A.
    Bednarek, D.
    Rudin, S.
    MEDICAL PHYSICS, 2006, 33 (06) : 2210 - 2211
  • [45] Real-Time Patient Skin Dose Mapping for Fluoroscopically Guided Interventional Procedures
    Bednarek, Daniel R.
    JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2022, 33 (03) : 233 - 237
  • [46] Monte Carlo investigation of backscatter factors for skin dose determination in interventional neuroradiology procedures
    Omar, Artur
    Benmakhlouf, Hamza
    Marteinsdottir, Maria
    Bujila, Robert
    Nowik, Patrik
    Andreo, Pedro
    MEDICAL IMAGING 2014: PHYSICS OF MEDICAL IMAGING, 2014, 9033
  • [47] Characterization of a MOSkin detector for in vivo skin dose measurements during interventional radiology procedures
    Safari, M. J.
    Wong, J. H. D.
    Ng, K. H.
    Jong, W. L.
    Cutajar, D. L.
    Rosenfeld, A. B.
    MEDICAL PHYSICS, 2015, 42 (05) : 2550 - 2559
  • [48] REPORTS OF SKIN INJURIES FOLLOWING HIGH X-RAY DOSE INTERVENTIONAL PROCEDURES
    NIGHTINGALE, SL
    JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1994, 272 (15): : 1160 - 1160
  • [49] Assessment of Maximum Patient Skin Dose for Interventional Radiology Procedures: Method and Uncertainty Analysis
    Farah, J.
    Trianni, A.
    Carinou, E.
    Dabin, J.
    Deangelis, C.
    Domienik, J.
    Knezevic, Z.
    Kopec, R.
    Malchair, F.
    Negri, A.
    Novak, L.
    Siiskonen, T.
    Vanhavere, F.
    Clairand, I.
    MEDICAL PHYSICS, 2013, 40 (06)
  • [50] Patient skin dose measurements during coronary interventional procedures using Gafchromic film
    Ying, C. K.
    Kandaiya, S.
    JOURNAL OF RADIOLOGICAL PROTECTION, 2010, 30 (03) : 585 - 596