Biomechanical Analysis of Combined Medial Calcar and Lateral Locked Plating Versus Isolated Lateral Locked Plating of Proximal Humerus Fractures

被引:1
|
作者
Kotler, Joshua A. [1 ,5 ]
Zuppke, Julia N. [2 ]
Abraham, Vivek M. [2 ]
Sanville, Jennifer A. [2 ]
Nabet, Austin C. [2 ]
Carofino, Bradley [3 ]
Gardner, Michael J. [4 ]
Smith, Christopher S. [2 ]
机构
[1] III Marine Expeditionary Force, Marine Logist Grp 3, Med Battal 3, Okinawa, Japan
[2] Naval Med Readiness & Training Ctr, Bone & Joint Sports Med Inst, Portsmouth, VA USA
[3] Atlantic Orthopaed Specialists, Virginia Beach, VA USA
[4] Stanford Univ, Dept Orthopaed Surg, Redwood City, CA USA
[5] III MEF, MLG 3, Med Battal 3, Unit 38404, FPO,AP 96604-8404, Okinawa, Japan
关键词
proximal humerus fracture; internal fixation; biomechanics; locking plates; bending; torsion; medial calcar plating; FIXATION; LOCKING; SUPPORT; EPIDEMIOLOGY; REDUCTION; PARALLEL; FRAGMENT;
D O I
10.1097/BOT.0000000000002619
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Objective:Medial calcar buttress plating combined with lateral locked plating is biomechanically tested against isolated lateral locked plating in synthetic humeri models for the treatment of proximal humerus fractures.Methods:Proximal humerus fractures (OTA/AO type 11-A2.1) were manufactured in 10 pairs of Sawbones humeri models (Sawbones, Pacific Research Laboratories, Vashon Island, WA). Specimen were randomly assigned and instrumented with either medial calcar buttress plating combined with lateral locked plating (CP) or isolated lateral locked plating (LP). Nondestructive torsional and axial load tests were performed to evaluate construct stiffness. Large-cycle axial tests were conducted followed by destructive ramp-to-failure tests. Cyclic stiffness was compared in both nondestructive and ultimate failure loads. Failure displacement was recorded and compared between groups.Results:The addition of medial calcar buttress plating to lateral locked plating constructs significantly increased the axial (P < 0.01) and torsional (P < 0.01) stiffness of the construct compared with isolated lateral locked plating by 95.56% and 37.46%, respectively. All models demonstrated greater axial stiffness (P < 0.01) after 5000 cycles of axial compression, not dependent on the fixation method. During destructive testing, the CP construct withstood 45.35% larger load (P < 0.01) and congruently exhibited 58% less humeral head displacement (P = 0.02) before failure when compared with the LP construct.Conclusion:This study demonstrates the biomechanical superiority of medial calcar buttress plating when combined with lateral locked plating as compared with isolated lateral locked plating of OTA/AO type 11-A2.1 proximal humerus in synthetic humeri models.
引用
收藏
页码:E355 / E360
页数:6
相关论文
共 50 条
  • [1] The importance of medial support in locked plating of proximal humerus fractures
    Gardner, Michael J.
    Weil, Yoram
    Barker, Joseph U.
    Kelly, Bryan T.
    Helfet, David L.
    Lorich, Dean G.
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2007, 21 (03) : 185 - 191
  • [2] Biomechanical effects of calcar screws and bone block augmentation on medial support in locked plating of proximal humeral fractures
    Katthagen, Jan Christoph
    Schwarze, Michael
    Meyer-Kobbe, Josefin
    Voigt, Christine
    Hurschler, Christof
    Lill, Helmut
    CLINICAL BIOMECHANICS, 2014, 29 (07) : 735 - 741
  • [3] Biomechanical in vitro assessment of screw augmentation in locked plating of proximal humerus fractures
    Roederer, Goetz
    Scola, Alexander
    Schmoelz, Werner
    Gebhard, Florian
    Windolf, Markus
    Hofmann-Fliri, Ladina
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2013, 44 (10): : 1327 - 1332
  • [4] Supplementation of Lateral Locked Plating for Distal Femur Fractures: A Biomechanical Study
    Fontenot, Philip B.
    Diaz, Miguel
    Stoops, Kyle
    Barrick, Brett
    Santoni, Brandon
    Mir, Hassan
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2019, 33 (12) : 642 - 648
  • [5] Biomechanical analysis of dual versus lateral locked plating in elderly bicondylar tibial plateau fractures: Does medial comminution matter?
    Velez, Dencel A. Garcia
    Headford, Mikel
    Suresh, Krishna Vangipuram
    Liberatos, Paraskevi Marousa
    Bledsoe, Gary
    Revak, Thomas
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2022, 53 (10): : 3109 - 3114
  • [6] Biomechanical evaluation of locked plating in proximal humeral fractures
    Sanders, Brett S.
    Bullington, Andrew B.
    McGillivary, Gary R.
    Hutton, William C.
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2007, 16 (02) : 229 - 234
  • [7] The Biomechanics of Locked Plating for Repairing Proximal Humerus Fractures With or Without Medial Cortical Support
    Lescheid, Jon
    Zdero, Rad
    Shah, Suraj
    Kuzyk, Paul R. T.
    Schemitsch, Emil H.
    JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 2010, 69 (05): : 1235 - 1242
  • [8] BIOMECHANICAL COMPARISON OF MEDIAL VERSUS LATERAL SIDED PLATING IN FEMORAL FRACTURES
    Al, Firat
    Tosun, Bilgehan
    Sinmazcelik, Tamer
    Ozmen, Mustafa
    ACTA ORTOPEDICA BRASILEIRA, 2018, 26 (04): : 265 - 270
  • [9] Additional fixation of medial plate over the unstable lateral locked plating of distal femur fractures: A biomechanical study
    Park, Kyeong-Hyeon
    Oh, Chang-Wug
    Park, Il-Hyung
    Kim, Joon-Woo
    Lee, Jin-Han
    Kim, Hee-June
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2019, 50 (10): : 1593 - 1598
  • [10] Clinical Results for Minimally Invasive Locked Plating of Proximal Humerus Fractures
    Roederer, Goetz
    Erhardt, Johannes
    Graf, Michael
    Kinzl, Lothar
    Gebhard, Florian
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2010, 24 (07) : 400 - 406