Biomechanical Analysis of Combined Medial Calcar and Lateral Locked Plating Versus Isolated Lateral Locked Plating of Proximal Humerus Fractures

被引:1
|
作者
Kotler, Joshua A. [1 ,5 ]
Zuppke, Julia N. [2 ]
Abraham, Vivek M. [2 ]
Sanville, Jennifer A. [2 ]
Nabet, Austin C. [2 ]
Carofino, Bradley [3 ]
Gardner, Michael J. [4 ]
Smith, Christopher S. [2 ]
机构
[1] III Marine Expeditionary Force, Marine Logist Grp 3, Med Battal 3, Okinawa, Japan
[2] Naval Med Readiness & Training Ctr, Bone & Joint Sports Med Inst, Portsmouth, VA USA
[3] Atlantic Orthopaed Specialists, Virginia Beach, VA USA
[4] Stanford Univ, Dept Orthopaed Surg, Redwood City, CA USA
[5] III MEF, MLG 3, Med Battal 3, Unit 38404, FPO,AP 96604-8404, Okinawa, Japan
关键词
proximal humerus fracture; internal fixation; biomechanics; locking plates; bending; torsion; medial calcar plating; FIXATION; LOCKING; SUPPORT; EPIDEMIOLOGY; REDUCTION; PARALLEL; FRAGMENT;
D O I
10.1097/BOT.0000000000002619
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Objective:Medial calcar buttress plating combined with lateral locked plating is biomechanically tested against isolated lateral locked plating in synthetic humeri models for the treatment of proximal humerus fractures.Methods:Proximal humerus fractures (OTA/AO type 11-A2.1) were manufactured in 10 pairs of Sawbones humeri models (Sawbones, Pacific Research Laboratories, Vashon Island, WA). Specimen were randomly assigned and instrumented with either medial calcar buttress plating combined with lateral locked plating (CP) or isolated lateral locked plating (LP). Nondestructive torsional and axial load tests were performed to evaluate construct stiffness. Large-cycle axial tests were conducted followed by destructive ramp-to-failure tests. Cyclic stiffness was compared in both nondestructive and ultimate failure loads. Failure displacement was recorded and compared between groups.Results:The addition of medial calcar buttress plating to lateral locked plating constructs significantly increased the axial (P < 0.01) and torsional (P < 0.01) stiffness of the construct compared with isolated lateral locked plating by 95.56% and 37.46%, respectively. All models demonstrated greater axial stiffness (P < 0.01) after 5000 cycles of axial compression, not dependent on the fixation method. During destructive testing, the CP construct withstood 45.35% larger load (P < 0.01) and congruently exhibited 58% less humeral head displacement (P = 0.02) before failure when compared with the LP construct.Conclusion:This study demonstrates the biomechanical superiority of medial calcar buttress plating when combined with lateral locked plating as compared with isolated lateral locked plating of OTA/AO type 11-A2.1 proximal humerus in synthetic humeri models.
引用
收藏
页码:E355 / E360
页数:6
相关论文
共 50 条
  • [21] Single lateral locked screw plating of bicondylar tibial plateau fractures
    Gosling, T
    Schandelmaier, P
    Muller, M
    Hankemeier, S
    Wagner, M
    Krettek, C
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2005, (439) : 207 - 214
  • [22] Locked Plating versus Nailing for Proximal Tibia Fractures: A Multicenter RCT
    Dunbar, Robert P.
    Egol, Kenneth A.
    Jones, Clifford B.
    Ostrum, Robert F.
    Humphrey, Catherine A.
    Ricci, William M.
    Phieffer, Laura S.
    Teague, David C.
    Sagi, H. Claude
    Pollak, Andrew N.
    Schmidt, Andrew H.
    Sems, Andrew
    Pape, Hans-Christoph
    Morshed, Saam
    Perez, Edward A.
    Tornetta III, Paul
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2023, 37 (04) : 155 - 160
  • [23] Biomechanical analysis of bicortical versus unicortical locked plating of mid-clavicular fractures
    Daniel Hamman
    Derek Lindsey
    Jason Dragoo
    Archives of Orthopaedic and Trauma Surgery, 2011, 131 : 773 - 778
  • [24] Biomechanical analysis of bicortical versus unicortical locked plating of mid-clavicular fractures
    Hamman, Daniel
    Lindsey, Derek
    Dragoo, Jason
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2011, 131 (06) : 773 - 778
  • [25] Locked Lateral Plating Versus Retrograde Nailing for Distal Femur Fractures: A Multicenter Randomized Trial
    Dunbar, Robert P.
    Egol, Kenneth A.
    Jones, Clifford B.
    Ertl, Jan P.
    Mullis, Brian
    Perez, Edward
    Collinge, Cory A.
    Ostrum, Robert
    Humphrey, Catherine
    Gardner, Michael J.
    Ricci, William M.
    Phieffer, Laura S.
    Teague, David
    Ertl, William
    Born, Christopher T.
    Zonno, Alan
    Siegel, Jodi
    Sagi, Henry Claude
    Pollak, Andrew
    Schmidt, Andrew H.
    Templeman, David C.
    Sems, Andrew
    Friess, Darin M.
    Pape, Hans-Christoph
    Krieg, James C.
    Tornetta III, Paul
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2023, 37 (02) : 70 - 76
  • [26] Second generation locked plating for complex proximal humerus fractures in very elderly patients
    Gavaskar, Ashok S.
    Karthik, Bhupesh B.
    Tummala, Naveen C.
    Srinivasan, Parthasarathy
    Gopalan, Hitesh
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2016, 47 (11): : 2534 - 2538
  • [27] Second generation locked plating of proximal humerus fractures—A prospective multicentre observational study
    Götz Röderer
    Johannes Erhardt
    Markus Kuster
    Paul Vegt
    Christian Bahrs
    Lothar Kinzl
    Florian Gebhard
    International Orthopaedics, 2011, 35 : 425 - 432
  • [28] Biomechanical Assessment of Locked Plating for the Fixation of Patella Fractures
    Wurm, Simone
    Augat, Peter
    Buehren, Volker
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2015, 29 (09) : E305 - E308
  • [29] Lateral rim variable angle locked plating versus tension band wiring of simple and complex patella fractures: a biomechanical study
    Stephen Warner
    Christoph Sommer
    Ivan Zderic
    William Woodburn
    Richard Castle
    Jessica Penman
    Eladio Saura-Sanchez
    David L. Helfet
    Boyko Gueorguiev
    Karl Stoffel
    Archives of Orthopaedic and Trauma Surgery, 2024, 144 : 2131 - 2140
  • [30] Lateral rim variable angle locked plating versus tension band wiring of simple and complex patella fractures: a biomechanical study
    Warner, Stephen
    Sommer, Christoph
    Zderic, Ivan
    Woodburn, William
    Castle, Richard
    Penman, Jessica
    Saura-Sanchez, Eladio
    Helfet, David L.
    Gueorguiev, Boyko
    Stoffel, Karl
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2024, 144 (05) : 2131 - 2140