Biomechanical analysis of dual versus lateral locked plating in elderly bicondylar tibial plateau fractures: Does medial comminution matter?

被引:1
|
作者
Velez, Dencel A. Garcia [1 ]
Headford, Mikel [1 ]
Suresh, Krishna Vangipuram [1 ]
Liberatos, Paraskevi Marousa [1 ]
Bledsoe, Gary [2 ]
Revak, Thomas [1 ]
机构
[1] St Louis Univ Hosp, St Louis, MO 63104 USA
[2] Dept Biomech Engn, St Louis, MO USA
关键词
Bicondylar tibial plateau fracture; Elderly; Osteoporosis; Dual versus lateral plating; Biomechanics; Medial comminution; LESS INVASIVE STABILIZATION; INTERNAL-FIXATION; OPEN REDUCTION; POSTEROMEDIAL FRAGMENT; OPERATIVE TREATMENT; PATIENTS OLDER; LOCKING PLATE; OUTCOMES; SINGLE; COMPLICATIONS;
D O I
10.1016/j.injury.2022.08.039
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Objective: To assess dual plating versus lateral locked plate fixation of bicondylar tibial plateau fractures in an elderly cadaveric model with and without medial bone loss Participants: 10 pairs of elderly (range 78-93 years of age) fresh frozen tibias. Intervention: Bicondylar tibial plateau fractures were created reproducing AO/OTA 41 C1 (without medial bone loss) and C2 fractures (with medial bone loss). Cadavers were randomized to 4 different groups. Groups 1 and 2 were 41 C1 fractures and fixated with either dual or lateral plating, respectively. Groups 3 and 4 were fixated in a similar fashion with medial metaphyseal bone loss (41 C2 fracture) with dual plating Group 3 and lateral plating group 4. Lateral plating consisted of a 3.5 mm 5-hole lateral plate (ALPS, ZimmerBiomet) with 6 bicortical locking screws proximally and two diaphyseal screws. Dual plat-ing groups underwent lateral plating and additional 3.5 mm 5-hole posteromedial 1/3 tubular plate (Zim-merBiomet) placed at the apex of the fracture with two shaft screws and one unicortical screw proxi-mally. Specimens were tested in a Mechanical Testing System (MTS) machine loading both condyles. Outcome measurements: Specimens were loaded to 300 N and coronal alignment obtained. Specimens were then cycled from 100 N to 700 N for 5000 cycles at 2 Hz. Average axial displacement, maximal displacement, average force and coronal alignment after 50 0 0 cycles were recorded. Lastly, force to failure was recorded at 100 N/sec. Results: Mean axial displacement was 4.21 mm ranging from 3.12 mm in group 1 to 5.92 mm in group 4 ( P = 0.51). Failure force averaged 3340 N ranging from 4342 N in group 1 to 2433 N in group 4 ( P = 0.36). Maximal displacement ranged from 3.69 mm in group 1 to 7.37 mm in group 4 ( P = 0.21). Change in coronal alignment ranged from 0.98 degrees in group 1 to 1.97 degrees in group 4 ( P = 0.45). No statistically significant difference was noted between all four groups for all data points. Conclusion: The results of this study demonstrate that a lateral locked plate may offer an alternative means of fixation in AO/OTA 41 C1 and C2 fractures. (c) 2022 Elsevier Ltd. All rights reserved.
引用
收藏
页码:3109 / 3114
页数:6
相关论文
共 50 条
  • [1] Dual locked plating of unstable bicondylar tibial plateau fractures
    Ozkaya, Ufuk
    Parmaksizoglu, Atilla Sancar
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2015, 46 : S9 - S13
  • [2] Lateral Locked Plating or Dual Plating: A Comparison of Two Methods in Simple Bicondylar Tibial Plateau Fractures
    Citak, Caner
    Kayali, Cemil
    Ozan, Firat
    Altay, Taskin
    Karahan, Huseyin Gokhan
    Yamak, Kamil
    CLINICS IN ORTHOPEDIC SURGERY, 2019, 11 (02) : 151 - 158
  • [3] Single lateral locked screw plating of bicondylar tibial plateau fractures
    Gosling, T
    Schandelmaier, P
    Muller, M
    Hankemeier, S
    Wagner, M
    Krettek, C
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2005, (439) : 207 - 214
  • [4] Comparative study of single lateral locked plating versus double plating in type C bicondylar tibial plateau fractures
    Raina, Sunil Kumar
    Awasthi, Bhanu
    INDIAN JOURNAL OF ORTHOPAEDICS, 2016, 50 (03) : 335 - 335
  • [5] Comparative study of single lateral locked plating versus double plating in type C bicondylar tibial plateau fractures
    Neogi, Devdatta Suhas
    Trikha, Vivek
    Mishra, Kaushal Kant
    Bandekar, Shivanand M.
    Yadav, Chandra Shekhar
    INDIAN JOURNAL OF ORTHOPAEDICS, 2015, 49 (02) : 193 - 198
  • [6] Comparative study of single lateral locked plating versus double plating in type C bicondylar tibial plateau fractures
    Devdatta Suhas Neogi
    Vivek Trikha
    Kaushal Kant Mishra
    Shivanand M. Bandekar
    Chandra Shekhar Yadav
    Indian Journal of Orthopaedics, 2015, 49 : 193 - 198
  • [7] Biomechanical Analysis of Combined Medial Calcar and Lateral Locked Plating Versus Isolated Lateral Locked Plating of Proximal Humerus Fractures
    Kotler, Joshua A.
    Zuppke, Julia N.
    Abraham, Vivek M.
    Sanville, Jennifer A.
    Nabet, Austin C.
    Carofino, Bradley
    Gardner, Michael J.
    Smith, Christopher S.
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2023, 37 (09) : E355 - E360
  • [8] Medial buttress versus lateral locked plating in a cadaver medial tibial plateau fracture model
    Ratcliff, Jennifer R.
    Werner, Fred W.
    Green, Jason K.
    Harley, Brian J.
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2007, 21 (07) : 444 - 448
  • [9] Reliability of locked plating in tibial plateau fractures with a medial component
    Ehlinger, M.
    Rahme, M.
    Moor, B. -K.
    Di Marco, A.
    Brinkert, D.
    Adam, P.
    Bonnomet, F.
    ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2012, 98 (02) : 173 - 179
  • [10] COMPARISON OF BICONDYLAR TIBIAL PLATEAU FRACTURES WITH DOUBLE OR SINGLE LATERAL LOCKED PLATE
    Arouca, Matheus Manolo
    Ricardo da Costa, Guilherme Henrique
    Leonhardt, Marcos Camargo
    Barbosa, Dennis
    Silva, Jorge dos Santos
    Kojima, Kodi Edson
    ACTA ORTOPEDICA BRASILEIRA, 2020, 28 (04): : 182 - 185