Biomechanical effects of calcar screws and bone block augmentation on medial support in locked plating of proximal humeral fractures

被引:67
|
作者
Katthagen, Jan Christoph [1 ]
Schwarze, Michael [2 ]
Meyer-Kobbe, Josefin [1 ]
Voigt, Christine [1 ]
Hurschler, Christof [2 ]
Lill, Helmut [1 ]
机构
[1] Diakoniekrankenhaus Friederikenstift gGmbH, Dept Trauma & Reconstruct Surg, D-30169 Hannover, Germany
[2] MHH, Lab Biomech & Biomat, D-30625 Hannover, Germany
关键词
Proximal humerus; Fracture; Medial support; Calcar screw; Dynamic locking screw; Bone augmentation; INTRAMEDULLARY FIBULAR ALLOGRAFT; LOCKING-PLATE; ENDOSTEAL IMPLANT; UNSTABLE FRACTURES; MINERAL DENSITY; OPEN REDUCTION; JOINT LOADS; IN-VITRO; FIXATION; GRAFT;
D O I
10.1016/j.clinbiomech.2014.06.008
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Background: The objective of this study was to investigate the biomechanical effects of medial fracture gap augmentation in locked plating of an unstable 2-part proximal humeral fracture with calcar screws and insertion of a corticocancellous bone block Furthermore the mechanical behavior of dynamic locking screws in the non-parallel arrangement of a proximal humeral plate was of interest. Methods: Thirty-two fresh frozen humeri were randomized in four equal groups. An unstable 2-part fracture was fixed by locked plating in all specimens. The basic screw setup was supplemented by additional calcar screws in one group. Humeral head screws were replaced by dynamic locking screws in a second group. The third group featured an additional corticocancellous femoral head allograft. Assessment of stiffness was followed by cyclic loading and load to failure tests. Resulting stiffness, fracture gap deflection and ultimate load were compared utilizing Bonferroni corrected t-test for independent samples. Findings: The mechanical effect of additional calcar screws was non-significant as compared to the basic screw configuration whereas bone block insertion significantly increased construct stiffness and failure load. The use of dynamic locking screws did not significantly reduce construct stiffness when compared to conventional locking screws. Interpretation: Additional calcar screws alone did not improve the initial biomechanical properties of an unstable 2-part proximal humeral fracture model. However bone block augmentation appeared to be a reliable alternative of additional bony support by raising stiffness and failure load. Dynamic locking screws did not show their expected dynamic component when used in a non-parallel arrangement. (C) 2014 Elsevier Ltd. All rights reserved.
引用
收藏
页码:735 / 741
页数:7
相关论文
共 50 条
  • [1] Biomechanical evaluation of locked plating in proximal humeral fractures
    Sanders, Brett S.
    Bullington, Andrew B.
    McGillivary, Gary R.
    Hutton, William C.
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2007, 16 (02) : 229 - 234
  • [2] Biomechanical Analysis of Combined Medial Calcar and Lateral Locked Plating Versus Isolated Lateral Locked Plating of Proximal Humerus Fractures
    Kotler, Joshua A.
    Zuppke, Julia N.
    Abraham, Vivek M.
    Sanville, Jennifer A.
    Nabet, Austin C.
    Carofino, Bradley
    Gardner, Michael J.
    Smith, Christopher S.
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2023, 37 (09) : E355 - E360
  • [3] Locked plating for proximal humeral fractures
    Cheung, Emilie V.
    CURRENT ORTHOPAEDIC PRACTICE, 2008, 19 (05): : 535 - 537
  • [4] Medial Calcar Support and Radiographic Outcomes of Plate Fixation for Proximal Humeral Fractures
    Lin, Shih-Jie
    Tsai, Yao-Hung
    Yang, Tien-Yu
    Shen, Shih-Hsun
    Huang, Kuo-Chin
    Lee, Mel S.
    BIOMED RESEARCH INTERNATIONAL, 2015, 2015
  • [5] The effect of medial calcar support on proximal humeral fractures treated with locking plates
    Hung, Chun-Yu
    Yeh, Chia-Yi
    Wen, Po-Chong
    Yeh, Wen-Ling
    Lin, Shih-Jie
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2022, 17 (01)
  • [6] The effect of medial calcar support on proximal humeral fractures treated with locking plates
    Chun-Yu Hung
    Chia-Yi Yeh
    Po-Chong Wen
    Wen-Ling Yeh
    Shih-Jie Lin
    Journal of Orthopaedic Surgery and Research, 17
  • [7] Cement augmentation of humeral head screws reduces early implant-related complications after locked plating of proximal humeral fractures
    Katthagen, J. Christoph
    Lutz, O.
    Voigt, C.
    Lill, H.
    Ellwein, A.
    OBERE EXTREMITAET-SCHULTER-ELLENBOGEN-HAND-UPPER EXTREMITY-SHOULDER ELBOW HAND, 2018, 13 (02): : 123 - 129
  • [8] Influence of Medial Support Screws on the Maintenance of Fracture Reduction after Locked Plating of Proximal Humerus Fractures
    Zeng LangQing
    Zeng LuLu
    Jiang YuWen
    Wei HaiFeng
    Zhang Wen
    Chen YunFeng
    中华医学杂志(英文版), 2018, (15) : 1827 - 1833
  • [9] The importance of medial support in locked plating of proximal humerus fractures
    Gardner, Michael J.
    Weil, Yoram
    Barker, Joseph U.
    Kelly, Bryan T.
    Helfet, David L.
    Lorich, Dean G.
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2007, 21 (03) : 185 - 191
  • [10] Influence of Medial Support Screws on the Maintenance of Fracture Reduction after Locked Plating of Proximal Humerus Fractures
    Zeng, Lang-Qing
    Zeng, Lu-Lu
    Jiang, Yu-Wen
    Wei, Hai-Feng
    Zhang, Wen
    Chen, Yun-Feng
    CHINESE MEDICAL JOURNAL, 2018, 131 (15) : 1827 - 1833