Dual-Energy Processing of X-ray Images of Beryl in Muscovite Obtained Using Pulsed X-ray Sources

被引:4
|
作者
Komarskiy, Alexander [1 ]
Korzhenevskiy, Sergey [1 ]
Ponomarev, Andrey [1 ]
Chepusov, Alexander [1 ]
机构
[1] Russian Acad Sci, Inst Electrophys, Ural Branch, Ekaterinburg 620016, Russia
基金
俄罗斯科学基金会;
关键词
dual-energy X-ray imaging; X-ray absorption; pulsed X-ray source; computed tomography; beryl; muscovite; image processing; TOMOGRAPHY; DIAMOND; DENSITY;
D O I
10.3390/s23094393
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This paper presents the development of a method for dual-energy processing of X-ray images using pulsed X-ray sources for the contrast detection of beryl in muscovite mica in 2D X-ray and CT images. These substances have similar chemical properties and are difficult to differentiate when one is against the background of the other using methods based on X-ray absorption. In the experiments, we used three pulsed X-ray sources with different maximum voltages. We performed modeling of the emission spectra and selection of the necessary energy bands due to X-ray absorbing filters: a positive effect was shown for dual-energy image processing when the function of converting X-ray radiation into a signal using the VIVIX-V 2323D detector was taken into account. As a result, a pulsed X-ray source with the pulse voltage of 330 kV was chosen for the contrast detection of beryl, with the content of 5-7% against the background of muscovite and the thickness up to 70 mm. Using this source and the developed mathematical algorithms, it is possible to obtain a band of low-energy radiation at the level of 70-80 keV, as well as high-energy radiation in the range of 180 keV. Methods based on the X-ray absorption can become both additional and independent methods for studying and monitoring membranes; these objects range from tens of nanometers to several micrometers in size.
引用
收藏
页数:18
相关论文
共 50 条
  • [21] X-Ray Filter Design and Its Evaluation in Dual-Energy X-Ray Absorptiometry (DXA)
    Kim, Kwang Hyun
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2010, 57 (04) : 2155 - 2158
  • [22] PROCESSING OF X-RAY IMAGES
    TRUSSELL, HJ
    PROCEEDINGS OF THE IEEE, 1981, 69 (05) : 615 - 627
  • [23] DUAL-ENERGY X-RAY ABSORPTIOMETRY OF THE CALCANEUS - COMPARISON WITH VERTEBRAL DUAL-ENERGY X-RAY ABSORPTIOMETRY AND QUANTITATIVE COMPUTED-TOMOGRAPHY
    LAVALJEANTET, AM
    BERGOT, C
    WILLIAMS, M
    DAVIDSON, K
    LAVALJEANTET, M
    CALCIFIED TISSUE INTERNATIONAL, 1995, 56 (01) : 14 - 18
  • [24] Development of a deep neural network for generating synthetic dual-energy chest x-ray images with single x-ray exposure
    Lee, Donghoon
    Kim, Hwiyoung
    Choi, Byungwook
    Kim, Hee-Joung
    PHYSICS IN MEDICINE AND BIOLOGY, 2019, 64 (11):
  • [25] Resolution enhancement in dual-energy x-ray imaging
    Gravel, P
    Després, P
    Beaudoin, G
    de Guise, JA
    Medical Imaging 2005: Image Processing, Pt 1-3, 2005, 5747 : 614 - 624
  • [26] Dual-energy X-ray imaging: benefits and limits
    Rebuffel, V.
    Dinten, J-M
    INSIGHT, 2007, 49 (10) : 589 - 594
  • [27] Dual-energy X-ray absorptiometry in early life
    Lapillonne, A
    Braillon, PM
    Delmas, PD
    Salle, BL
    HORMONE RESEARCH, 1997, 48 : 43 - 49
  • [28] SIMULATION STUDIES OF DUAL-ENERGY X-RAY ABSORPTIOMETRY
    SORENSON, JA
    DUKE, PR
    SMITH, SW
    MEDICAL PHYSICS, 1989, 16 (01) : 75 - 80
  • [29] Dual-energy X-ray absorptiometry scan: Guidelines
    Haymann, Jean-Philippe
    PROGRES EN UROLOGIE, 2010, 20 (04): : F119 - F122
  • [30] DUAL-ENERGY X-RAY ABSORPTIOMETRY - INTEREST IN ORTHOPEDICS
    MAUGARS, Y
    BERTHELOT, JM
    DELECRIN, J
    TRECANT, M
    PASSUTI, N
    DACULSI, G
    PROST, A
    REVUE DE CHIRURGIE ORTHOPEDIQUE ET REPARATRICE DE L APPAREIL MOTEUR, 1995, 81 (04): : 326 - 332