Dual-Energy Processing of X-ray Images of Beryl in Muscovite Obtained Using Pulsed X-ray Sources

被引:4
|
作者
Komarskiy, Alexander [1 ]
Korzhenevskiy, Sergey [1 ]
Ponomarev, Andrey [1 ]
Chepusov, Alexander [1 ]
机构
[1] Russian Acad Sci, Inst Electrophys, Ural Branch, Ekaterinburg 620016, Russia
基金
俄罗斯科学基金会;
关键词
dual-energy X-ray imaging; X-ray absorption; pulsed X-ray source; computed tomography; beryl; muscovite; image processing; TOMOGRAPHY; DIAMOND; DENSITY;
D O I
10.3390/s23094393
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This paper presents the development of a method for dual-energy processing of X-ray images using pulsed X-ray sources for the contrast detection of beryl in muscovite mica in 2D X-ray and CT images. These substances have similar chemical properties and are difficult to differentiate when one is against the background of the other using methods based on X-ray absorption. In the experiments, we used three pulsed X-ray sources with different maximum voltages. We performed modeling of the emission spectra and selection of the necessary energy bands due to X-ray absorbing filters: a positive effect was shown for dual-energy image processing when the function of converting X-ray radiation into a signal using the VIVIX-V 2323D detector was taken into account. As a result, a pulsed X-ray source with the pulse voltage of 330 kV was chosen for the contrast detection of beryl, with the content of 5-7% against the background of muscovite and the thickness up to 70 mm. Using this source and the developed mathematical algorithms, it is possible to obtain a band of low-energy radiation at the level of 70-80 keV, as well as high-energy radiation in the range of 180 keV. Methods based on the X-ray absorption can become both additional and independent methods for studying and monitoring membranes; these objects range from tens of nanometers to several micrometers in size.
引用
收藏
页数:18
相关论文
共 50 条
  • [31] DUAL-ENERGY X-RAY ABSORPTIOMETRY IN NEUROMUSCULAR DISEASES
    KANDA, F
    FUJII, Y
    TAKAHASHI, K
    FUJITA, T
    MUSCLE & NERVE, 1994, 17 (04) : 431 - 435
  • [32] Technical standardization for dual-energy X-ray absorptiometry
    Leib, E
    JOURNAL OF CLINICAL DENSITOMETRY, 2004, 7 (01) : 27 - 36
  • [33] ENHANCED PRECISION WITH DUAL-ENERGY X-RAY ABSORPTIOMETRY
    MAZESS, R
    CHESNUT, CH
    MCCLUNG, M
    GENANT, H
    CALCIFIED TISSUE INTERNATIONAL, 1992, 51 (01) : 14 - 17
  • [34] The use of dual-energy x-ray absorptiometry in animals
    Grier, SJ
    Turner, AS
    Alvis, MR
    INVESTIGATIVE RADIOLOGY, 1996, 31 (01) : 50 - 62
  • [35] Dual-energy X-ray absorptiometry and body composition
    Laskey, MA
    NUTRITION, 1996, 12 (01) : 45 - 51
  • [36] Simultaneous dual-energy X-ray stereo imaging
    Mokso, Rajmund
    Oberta, Peter
    JOURNAL OF SYNCHROTRON RADIATION, 2015, 22 : 1078 - 1082
  • [37] Multiple view dual-energy x-ray imaging
    Evans, P
    Robinson, M
    Hon, HW
    35TH ANNUAL 2001 INTERNATIONAL CARNAHAN CONFERENCE ON SECURITY TECHNOLOGY, PROCEEDINGS, 2001, : 103 - 107
  • [38] Dual-Energy X-Ray Fluoroscopy Imaging System
    Virshup, G.
    Fu, D.
    Richmond, M.
    Mostafavi, H.
    Ganguly, A.
    MEDICAL PHYSICS, 2014, 41 (06) : 103 - 103
  • [39] Dual-energy X-ray Absorptiometry Quality Matters
    Krueger, Diane
    Binkley, Neil
    Morgan, Sarah
    JOURNAL OF CLINICAL DENSITOMETRY, 2018, 21 (02) : 155 - 156
  • [40] X-RAY-IMAGING SENSOR USING CDTE CRYSTALS FOR DUAL-ENERGY X-RAY ABSORPTIOMETRY
    OHTSUCHI, T
    TSUTSUI, H
    OHMORI, K
    BABA, S
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1994, 41 (05) : 1740 - 1745