Validation of a digital method for patient-specific verification of VMAT treatment using a 2D ionisation detector array

被引:1
|
作者
U'wais, Fatima Adel [1 ]
Radzi, Yasmin [2 ]
Rizan, Naslinda Noor [3 ]
Zin, Hafiz M. [1 ]
机构
[1] Univ Sains Malaysia, Adv Med & Dent Inst, Kepala Batas 13200, Pulau Pinang, Malaysia
[2] Univ Sains Malaysia, Sch Phys, George Town 11800, Malaysia
[3] Gleneagles Hosp, George Town, Malaysia
关键词
VMAT; Patient-specific QA; Log file; QUALITY-ASSURANCE; LOG FILES; MLC; THERAPY; ACCURACY; QA;
D O I
10.1016/j.radphyschem.2022.110536
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
VMAT treatment involves the delivery of complex beam parameters including the dynamic multi-leaf collimators (MLC) from a linac. The use of a detector array has become a standard method to verify the treatment accuracy before the treatment planned is delivered to the patient with some limitations. This study aims to evaluate the accuracy of a high-resolution, digital method using linac log data for VMAT treatment verification. The log data was obtained from a Versa HD (Elekta ltd., Crawley, UK) linac during VMAT treatment. All the dynamic treatment parameters including MLC position, and MLC speed, were recorded at the rate of 4 Hz in the log data. The treatment delivery was also measured simultaneously using an Octavius 1500 2D ionisation chamber array (PTW, Freiburg, Germany) during the log data measurements. The parameters were extracted and analysed using algorithms written in MATLAB (MathWorks, Natick, MA). The results demonstrated that the log data can track MLC leaves with an accuracy of 1 mm at speeds ranging from 3.04 to 3.40 cm/s. Evaluation of the fluence generated for the VMAT delivery using log data was shown to agree well with the planned dose distribution measured in the 2D detector array, with an average gamma pass rate of 97.5% at 3%/3 mm. Log data obtained a higher gamma pass rate of 98.5% compared to the 2D detector array of 97.5%. The digital linac log data provides the basis for an essential high-resolution real-time verification tool that may be used for routine VMAT verification.
引用
收藏
页数:7
相关论文
共 50 条
  • [41] IMRT plan verification using a 2D ion chamber array
    Spezi, E
    Angelini, AL
    Romani, F
    Ferri, A
    RADIOTHERAPY AND ONCOLOGY, 2005, 76 : S176 - S177
  • [42] Research of a novel architecture of a 2D digital array working as position sensitive detector
    Li, Tian-Ze
    Wang, Sheng-De
    Shen, Jin
    Wang, Shu-Yun
    Guangdian Gongcheng/Opto-Electronic Engineering, 2007, 34 (01): : 46 - 49
  • [43] Development of patient-specific phantoms for verification of SBRT planning using 3D printer
    Hong, C. S.
    Oh, D.
    Ju, S. G.
    Kim, M.
    Koo, B. Y.
    Park, H. C.
    Choi, D. H.
    Pyo, H.
    RADIOTHERAPY AND ONCOLOGY, 2017, 123 : S399 - S400
  • [44] Experimental validation of 3D printed patient-specific implants using digital image correlation and finite element analysis
    Sutradhar, Alok
    Park, Jaejong
    Carrau, Diana
    Miller, Michael J.
    COMPUTERS IN BIOLOGY AND MEDICINE, 2014, 52 : 8 - 17
  • [45] Validation of a liquid-filled ionization chambers 2D array for HyperArc plan verification
    Calvo-Ortega, J.
    POZO-MASSO, M.
    MORAGUES-FEMENIA, S.
    LAOSA-BELLO, C.
    ZAMORA, A.
    RADIOTHERAPY AND ONCOLOGY, 2022, 170 : S1324 - S1325
  • [46] SEGMENTATION OF 2D STRESS ECHOCARDIOGRAPHY SEQUENCES USING REST-BASED PATIENT-SPECIFIC PRIOR INFORMATION
    Zabair, Adeala T.
    Noble, J. Alison
    2010 7TH IEEE INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING: FROM NANO TO MACRO, 2010, : 304 - 307
  • [47] DOSIMETRIC VERIFICATION OF IMRT TREATMENTS USING A 2D ION CHAMBER ARRAY
    Marcantonini, M.
    Raymondi, C.
    Zucchetti, C.
    Leogrande, M. P.
    Aristei, C.
    Gobbi, G.
    RADIOTHERAPY AND ONCOLOGY, 2011, 99 : S511 - S511
  • [48] 2D dose reconstruction of IMRT patient-specific QA based on log file
    Mubarok, Sayid
    Wahyu, Wibowo Edy
    Supriyanto, Pawiro Ardjo
    RADIATION PHYSICS AND CHEMISTRY, 2020, 166
  • [49] Verification measurements of an eMC algorithm using a 2D ion chamber array
    Wanklyn, Mark D.
    Kidane, Ghirmay
    Crees, Liz
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2016, 17 (05): : 320 - 328
  • [50] Enhanced dynamic wedge commissioning using 2D MAPCHECK detector array
    Lief, E
    Han, K
    De Wyngaert, J
    MEDICAL PHYSICS, 2004, 31 (06) : 1885 - 1885