Experimental validation of 3D printed patient-specific implants using digital image correlation and finite element analysis

被引:67
|
作者
Sutradhar, Alok [1 ,2 ]
Park, Jaejong [2 ]
Carrau, Diana [3 ]
Miller, Michael J. [1 ]
机构
[1] Ohio State Univ, Dept Plast Surg, Columbus, OH 43210 USA
[2] Ohio State Univ, Dept Mech & Aerosp Engn, Columbus, OH 43210 USA
[3] Ohio State Univ, Coll Med, Columbus, OH 43210 USA
基金
美国国家科学基金会;
关键词
Craniofacial implants; Topology optimization; Segmental bone defect; Digital image correlation; Masticatory simulation; RECONSTRUCTION; OPTIMIZATION; MODELS;
D O I
10.1016/j.compbiomed.2014.06.002
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
With the dawn of 3D printing technology, patient-specific implant designs are set to have a paradigm shift. A topology optimization method in designing patient-specific craniofacial implants has been developed to ensure adequate load transfer mechanism and restore the form and function of the mid-face. Patient-specific finite element models are used to design these implants and to validate whether they are viable for physiological loading such as mastication. Validation of these topology optimized finite element models using mechanical testing is a critical step. Instead of inserting the implants into a cadaver or patient, we embed the implants into the computer-aided skull model of a patient and, fuse them together to 3D print the complete skull model with the implant. Masticatory forces are applied in the molar region to simulate chewing and measure the stress-strain trajectory. Until recently, strain gages have been used to measure strains for validation. Digital Image Correlation (DIC) method is a relatively new technique for full-field strain measurement which provides a continuous deformation field data. The main objective of this study is to validate the finite element model of patient-specific craniofacial implants against the strain data from the DIC obtained during the mastication simulation and show that the optimized shapes provide adequate load-transfer mechanism. Patient-specific models are obtained from CT scans. The principal maximum and minimum strains are compared. The computational and experimental approach to designing patient-specific implants proved to be a viable technique for mid-face craniofacial reconstruction. (C) 2014 Elsevier Ltd. All rights reserved.
引用
收藏
页码:8 / 17
页数:10
相关论文
共 50 条
  • [1] Patient-Specific 3D Finite-Element Analysis of Miniscrew Implants during Orthodontic Treatment
    Ammar, Hussein H.
    Mucino, Victor H.
    Ngan, Peter
    Crout, Richard J.
    Mukdadi, Osama M.
    [J]. IMECE2009: PROCEEDINGS OF THE ASME INTERNATIONAL MECHANICAL ENGINEERING CONGRESS AND EXPOSITION, VOL 2, 2010, : 109 - 112
  • [2] Development of 3D printed patient-specific skull implants based on 3d surface scans
    Fabian Kropla
    Dirk Winkler
    Dirk Lindner
    Patrick Knorr
    Sebastian Scholz
    Ronny Grunert
    [J]. 3D Printing in Medicine, 9
  • [3] Development of 3D printed patient-specific skull implants based on 3d surface scans
    Kropla, Fabian
    Winkler, Dirk
    Lindner, Dirk
    Knorr, Patrick
    Scholz, Sebastian
    Grunert, Ronny
    [J]. 3D PRINTING IN MEDICINE, 2023, 9 (01)
  • [4] Designing patient-specific 3D printed craniofacial implants using a novel topology optimization method
    Sutradhar, Alok
    Park, Jaejong
    Carrau, Diana
    Nguyen, Tam H.
    Miller, Michael J.
    Paulino, Glaucio H.
    [J]. MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2016, 54 (07) : 1123 - 1135
  • [5] Designing patient-specific 3D printed craniofacial implants using a novel topology optimization method
    Alok Sutradhar
    Jaejong Park
    Diana Carrau
    Tam H. Nguyen
    Michael J. Miller
    Glaucio H. Paulino
    [J]. Medical & Biological Engineering & Computing, 2016, 54 : 1123 - 1135
  • [6] Analysis of the Effectiveness of 3D Printed Patient-Specific Implants for Reconstruction of Maxillary Defect Secondary to Mucormycosis
    Aditya Mohan Alwala
    K. Ramesh
    Himaja Swayampakula
    Nanda Gopal Vura
    Sheraz Bar Shaik
    K. Vidya Hiranmayi
    [J]. Journal of Maxillofacial and Oral Surgery, 2023, 22 : 728 - 733
  • [7] Analysis of the Effectiveness of 3D Printed Patient-Specific Implants for Reconstruction of Maxillary Defect Secondary to Mucormycosis
    Alwala, Aditya Mohan
    Ramesh, K.
    Swayampakula, Himaja
    Vura, Nanda Gopal
    Shaik, Sheraz Bar
    Hiranmayi, K. Vidya
    [J]. JOURNAL OF MAXILLOFACIAL & ORAL SURGERY, 2023, 22 (03): : 728 - 733
  • [8] Finite element analysis of patient-specific additive-manufactured implants
    Namvar, Arman
    Lozanovski, Bill
    Downing, David
    Williamson, Tom
    Kastrati, Endri
    Shidid, Darpan
    Hill, David
    Buehner, Ulrich
    Ryan, Stewart
    Choong, Peter F.
    Sanaei, Reza
    Leary, Martin
    Brandt, Milan
    [J]. FRONTIERS IN BIOENGINEERING AND BIOTECHNOLOGY, 2024, 12
  • [9] Patient-specific finite element analysis of femurs with cemented hip implants
    Katz, Yekutiel
    Lubovsky, Omri
    Yosibash, Zohar
    [J]. CLINICAL BIOMECHANICS, 2018, 58 : 74 - 89
  • [10] Analysis of Printed Circuit Boards strains using finite element analysis and digital image correlation
    Falk, Alexandru
    Marsavina, Liviu
    Pop, Octavian
    [J]. FRATTURA ED INTEGRITA STRUTTURALE, 2020, Gruppo Italiano Frattura (51): : 541 - 551