Validation of a digital method for patient-specific verification of VMAT treatment using a 2D ionisation detector array

被引:1
|
作者
U'wais, Fatima Adel [1 ]
Radzi, Yasmin [2 ]
Rizan, Naslinda Noor [3 ]
Zin, Hafiz M. [1 ]
机构
[1] Univ Sains Malaysia, Adv Med & Dent Inst, Kepala Batas 13200, Pulau Pinang, Malaysia
[2] Univ Sains Malaysia, Sch Phys, George Town 11800, Malaysia
[3] Gleneagles Hosp, George Town, Malaysia
关键词
VMAT; Patient-specific QA; Log file; QUALITY-ASSURANCE; LOG FILES; MLC; THERAPY; ACCURACY; QA;
D O I
10.1016/j.radphyschem.2022.110536
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
VMAT treatment involves the delivery of complex beam parameters including the dynamic multi-leaf collimators (MLC) from a linac. The use of a detector array has become a standard method to verify the treatment accuracy before the treatment planned is delivered to the patient with some limitations. This study aims to evaluate the accuracy of a high-resolution, digital method using linac log data for VMAT treatment verification. The log data was obtained from a Versa HD (Elekta ltd., Crawley, UK) linac during VMAT treatment. All the dynamic treatment parameters including MLC position, and MLC speed, were recorded at the rate of 4 Hz in the log data. The treatment delivery was also measured simultaneously using an Octavius 1500 2D ionisation chamber array (PTW, Freiburg, Germany) during the log data measurements. The parameters were extracted and analysed using algorithms written in MATLAB (MathWorks, Natick, MA). The results demonstrated that the log data can track MLC leaves with an accuracy of 1 mm at speeds ranging from 3.04 to 3.40 cm/s. Evaluation of the fluence generated for the VMAT delivery using log data was shown to agree well with the planned dose distribution measured in the 2D detector array, with an average gamma pass rate of 97.5% at 3%/3 mm. Log data obtained a higher gamma pass rate of 98.5% compared to the 2D detector array of 97.5%. The digital linac log data provides the basis for an essential high-resolution real-time verification tool that may be used for routine VMAT verification.
引用
下载
收藏
页数:7
相关论文
共 50 条
  • [31] Patient-Specific QA of Intensity-Modulated Arc Therapy with 2D Diode Array: Initial Experience
    Tang, G.
    Yi, B.
    MEDICAL PHYSICS, 2009, 36 (06)
  • [32] Validation of Motorized Wedge Effective Isodose Angle with a 2D Array Detector
    Gamit, Jaimin Samabhai
    Rao, Shreekripa
    Nagesh, Jyothi
    Nair, Sarath S.
    Charan, Shambhavi
    Dsouza, Rechal Nisha
    Sharan, Krishna
    Chandraguthi, Srinidhi
    Iranian Journal of Medical Physics, 2020, 17 (06) : 380 - 385
  • [33] A method to improve fluence resolution derived from two-dimensional detector array measurements for patient-specific IMRT verification using the information collected in dynalog files
    Agustin, Juan
    Santiago, Calama
    Infante Utrilla, Miguel Angel
    Lavado Rodriguez, Maria Elisa
    JOURNAL OF MEDICAL PHYSICS, 2015, 40 (01) : 5 - 12
  • [34] Impact of Detector Element-Specific Angular Correction Factors for the MaxtriXX Ion Chamber Array for Patient-Specific Dose Validation
    Casares, O.
    Kim, S.
    Armas, J.
    Papanikolaou, N.
    Gutierrez, A.
    MEDICAL PHYSICS, 2013, 40 (06)
  • [35] Comparative performance analysis of 2D and 3D gamma metrics for patient specific QA in VMAT using Octavius 4D with 2D-Array 1500
    Pal, Bipasha
    Pal, Angshuman
    Bag, Santanu
    Ali, Md Abbas
    Das, Suresh
    Palit, Soura
    Sarkar, Papai
    Mallik, Suman
    Goswami, Jyotirup
    Das, Sayan
    Manir, Kazi Sazzad
    Sen, Arijit
    Mondol, Monidipa
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2021, 91 : 18 - 27
  • [36] Dose Calculation Grid for 3D Dose Verification of VMAT Using Rotating 2D Array of Finite-Size Detectors
    Saito, A.
    Nakashima, T.
    Okumura, T.
    Aita, M.
    Hioki, K.
    Kawahara, D.
    Masuda, H.
    Miki, K.
    Mori, M.
    Naito, K.
    Ochi, Y.
    Tsubouchi, K.
    Ohno, Y.
    Nagata, Y.
    MEDICAL PHYSICS, 2018, 45 (06) : E282 - E282
  • [37] Initial Experience of Patient Specific Rotational Quality Assurance for VMAT Using a Cylindrical Diodes Array Detector System
    Qi, S.
    Hu, A.
    Westerly, D.
    Rice, H.
    Newman, F.
    Stuhr, K.
    Chen, C.
    Raben, D.
    Kavanagh, B.
    Gaspar, L.
    Miften, M.
    MEDICAL PHYSICS, 2010, 37 (06)
  • [38] A method to enhance 2D ion chamber array patient specific quality assurance for IMRT
    Rogelio Manuel Diaz Moreno
    Daniel Venencia
    Edgardo Garrigo
    Yakov Pipman
    Australasian Physical & Engineering Sciences in Medicine, 2017, 40 : 145 - 151
  • [39] A method to enhance 2D ion chamber array patient specific quality assurance for IMRT
    Diaz Moreno, Rogelio Manuel
    Venencia, Daniel
    Garrigo, Edgardo
    Pipman, Yakov
    AUSTRALASIAN PHYSICAL & ENGINEERING SCIENCES IN MEDICINE, 2017, 40 (01) : 145 - 151
  • [40] Dosimetric characteristics of a 2D silicon diode array for stereotactic radiotherapy end-to-end patient-specific QA
    Bai, Long
    Xiao, Qing
    Wang, Qiang
    Zhao, Jianling
    Li, Guangjun
    Bai, Sen
    RADIATION PHYSICS AND CHEMISTRY, 2020, 173