Do cobalt and chromium blood metal ion levels normalize after revision of failed metal-on-metal total hip replacements?

被引:0
|
作者
Jungwirth-Weinberger, Anna [1 ,2 ]
Hanreich, Carola [1 ]
Kasparek, Maximilian F. [3 ]
Renner, Lisa [4 ]
Waldstein, Wenzel [5 ]
Boettner, Friedrich [1 ]
机构
[1] Hosp Special Surg, 535 East 70th St, New York, NY 10021 USA
[2] Kantonsspital Baden, Ergel 1, CH-5404 Baden, Switzerland
[3] Evangel Krankenhaus, Hans Sachs Gasse 10-12, A-1180 Vienna, Austria
[4] Charite, Charitepl 1, D-10117 Berlin, Germany
[5] AKH Wien, Wahringer Gurtel 18-20, A-1090 Vienna, Austria
关键词
Metal-on-metal; Total hip arthroplasty; Revision; Chromium; Cobalt; ARTHROPLASTY; DISLOCATION; BEARING;
D O I
10.1007/s00402-021-04206-2
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Introduction Increased cobalt (Co) and chromium (Cr) serum levels are one reason for revision surgery in metal on metal (MoM) total hip arthroplasty (THA) patients. Dual mobility liners are a simple revision option; however, they preserve the metal shell and stem and it is therefore not clear if metal ion levels will fully normalize after revision surgery. Material and methods Between April 2013 and December 2017 25 hips (24 patients) underwent revision from a MoM THA to an off-label dual mobility liner. Five patients were lost to follow-up and one patient refused leaving 18 patients (11 men, 7 female, average age 63.9 years) for pre- and postoperative metal ion level blood tests at a minimum follow-up of 2 years. Results Fourteen patients were revised for osteolysis, two for elevated metal ion levels and two for fluid or cysts around the femoral or acetabular component. The average preoperative Co and Cr levels were 8.3 mu g/l and 5.0 mu g/l, respectively. At a minimum follow-up of 2 years (30-95 months), metal ions dropped to 0.8 mu g/l. Harris Hip Score (HHS), Hip Osteoarthritis Outcome Score (HOOS), Visual Analog Scale (VAS) and the UCLA activity score improved non-significantly from pre- to postoperative. There was one postoperative complication in the study cohort. One patient with persisting pain required revision surgery to a standard acetabular component during the follow-up period. Conclusion The off-label use of a dual-mobility liner in the current study resulted in normalization of the metal ion levels suggesting that preserving the cobalt-chromium acetabular component has little impact on ion levels. In addition, dual mobility liners have a low complication and revision rate.
引用
收藏
页码:1217 / 1221
页数:5
相关论文
共 50 条
  • [41] CoCrMo metal-on-metal hip replacements
    Liao, Yifeng
    Hoffman, Emily
    Wimmer, Markus
    Fischer, Alfons
    Jacobs, Joshua
    Marks, Laurence
    [J]. PHYSICAL CHEMISTRY CHEMICAL PHYSICS, 2013, 15 (03) : 746 - 756
  • [42] Predicting Wear and Blood Metal Ion Levels in Metal-on-Metal Hip Resurfacing
    Matthies, Ashley K.
    Henckel, Johann
    Cro, Suzie
    Suarez, Alexander
    Noble, Philip C.
    Skinner, John
    Hart, Alister J.
    [J]. JOURNAL OF ORTHOPAEDIC RESEARCH, 2014, 32 (01) : 167 - 174
  • [43] Serum metal ion levels after second-generation metal-on-metal total hip arthroplasty
    Imanishi, Takao
    Hasegawa, Masahiro
    Sudo, Akihiro
    [J]. ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2010, 130 (12) : 1447 - 1450
  • [44] Serum metal ion levels after second-generation metal-on-metal total hip arthroplasty
    Takao Imanishi
    Masahiro Hasegawa
    Akihiro Sudo
    [J]. Archives of Orthopaedic and Trauma Surgery, 2010, 130 : 1447 - 1450
  • [45] Predictors and patterns of elevated blood metal ions levels after metal-on-metal total hip arthroplasty
    Gonzalez, Amanda
    Lozeron, Elise Dupuis
    Barea, Christophe
    Peter, Robin
    Christofilopoulos, Panayiotis
    Hoffmeyer, Pierre J.
    Hannouche, Didier
    Wolff, Anne Lubbeke
    [J]. SWISS MEDICAL WEEKLY, 2017, 147 : 47S - 48S
  • [46] Insufficient Acetabular Version Increases Blood Metal Ion Levels after Metal-on-metal Hip Resurfacing
    Hart, Alister J.
    Skinner, John A.
    Henckel, Johann
    Sampson, Barry
    Gordon, Fabiana
    [J]. CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2011, 469 (09) : 2590 - 2597
  • [47] Changes in Cobalt and Chromium Levels After Metal-on-Metal Hip Resurfacing in Young, Active Chinese Patients
    Yang, Jing
    Shen, Bin
    Zhou, ZongKe
    Pei, Fuxing
    Kang, PengDe
    [J]. JOURNAL OF ARTHROPLASTY, 2011, 26 (01): : 65 - 70
  • [48] Metal-on-metal bearings total hip arthroplasty: The cobalt and chromium ions release concern
    Delaunay, C.
    Petit, I.
    Learmonth, I. D.
    Oger, P.
    Vendittoli, P. A.
    [J]. ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2010, 96 (08) : 894 - 904
  • [49] Cobalt and chromium concentrations in patients with metal-on-metal and other cementless total hip arthroplasty
    Maezawa, K
    Nozawa, M
    Hirose, T
    Matsuda, K
    Yasuma, M
    Shitoto, K
    Kurosawa, H
    [J]. ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2002, 122 (05) : 283 - 287
  • [50] Metal ion levels and revision rates in metal-on-metal hip resurfacing arthroplasty: a comparative study
    Robinson, Patrick G.
    Wilkinson, Andrew J.
    Meek, Robert M. D.
    [J]. HIP INTERNATIONAL, 2014, 24 (02) : 123 - 128