Insufficient Acetabular Version Increases Blood Metal Ion Levels after Metal-on-metal Hip Resurfacing

被引:58
|
作者
Hart, Alister J. [1 ]
Skinner, John A. [2 ]
Henckel, Johann [1 ]
Sampson, Barry [3 ,4 ]
Gordon, Fabiana [5 ]
机构
[1] Univ London Imperial Coll Sci Technol & Med, Dept Orthopaed Surg, London SW7 2AZ, England
[2] UCL, Dept Orthopaed Surg, Royal Natl Orthopaed Hosp, London, England
[3] Univ London Imperial Coll Sci Technol & Med, Dept Clin Chem, London SW7 2AZ, England
[4] Imperial Coll Healthcare NHS Trust, London, England
[5] Univ London Imperial Coll Sci Technol & Med, Stat Advisory Serv, London SW7 2AZ, England
关键词
30-YEAR FOLLOW-UP; SURFACE REPLACEMENT; ACTIVE PATIENTS; ARTHROPLASTY; COMPONENT; COBALT; WEAR; ORIENTATION; CHROMIUM; CUP;
D O I
10.1007/s11999-011-1930-y
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background Many factors affect the blood metal ion levels after metal-on-metal (MOM) hip arthroplasty. The main surgically adjustable variable is the amount of coverage of the head provided by the cup which is a function of the inclination and version angles. However, most studies have used plain radiographs which have questionable precision and accuracy, particularly for version and large diameter metal heads; further, these studies do not simultaneously assess version and inclination. Thus the relationship between version and blood metal ions levels has not been resolved. Questions/purposes We determined whether cup inclination and version influence blood metal ion levels while adjusting for age at assessment, gender, body mass index, horizontal femoral offset, head size, manufacturer hip type, and Oxford hip score. Patients and Methods We prospectively followed 100 individuals (51 females, 49 males) with unilateral MOM hip resurfacing who underwent clinical assessment, CT scanning, and blood metal ion measurement. Multiple regression analysis was used to determine which variables were predictors of blood metal ion levels and to model the effect of these variables. Results Only cup inclination, version angles, and gender influenced blood cobalt or chromium levels. Cobalt and chromium levels positively correlated with inclination angle and negatively correlated with version angle. The effect of changes in version angle was less than for inclination angle. Based on our observations, we developed a formula to predict the effect of these parameters on metal ion levels. Conclusions Our data suggest insufficient cup version can cause high blood metal ions after MOM hip arthroplasty. We were unable to show that excessive version caused high levels. Level of Evidence Level II, prognostic study. See Guidelines for Authors for a complete description of levels of evidence.
引用
收藏
页码:2590 / 2597
页数:8
相关论文
共 50 条
  • [1] Predicting Wear and Blood Metal Ion Levels in Metal-on-Metal Hip Resurfacing
    Matthies, Ashley K.
    Henckel, Johann
    Cro, Suzie
    Suarez, Alexander
    Noble, Philip C.
    Skinner, John
    Hart, Alister J.
    [J]. JOURNAL OF ORTHOPAEDIC RESEARCH, 2014, 32 (01) : 167 - 174
  • [2] The effect of obesity on blood metal ion levels after hip resurfacing and metal-on-metal total hip replacement
    Sawalha, Seif
    Ravikumar, Raveena
    Chowdhury, Emyr A.
    Massraf, Araz
    [J]. HIP INTERNATIONAL, 2012, 22 (01) : 107 - 112
  • [3] Correlation between inclination of the acetabular component and metal ion levels in metal-on-metal hip resurfacing replacement
    De Haan, R.
    Pattyn, C.
    Gill, H. S.
    Murray, D. W.
    Campbell, P. A.
    De Smet, K.
    [J]. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2008, 90B (10): : 1291 - 1297
  • [4] Metal ion levels in a triathlete with a metal-on-metal resurfacing arthroplasty of the hip
    De Haan, R.
    Campbell, P.
    Reid, S.
    Skipor, A. K.
    De Smet, K.
    [J]. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2007, 89B (04): : 538 - 541
  • [5] Hip Resurfacing Versus Metal-on-Metal Total Hip Arthroplasty Are Metal Ion Levels Different?
    Kuzyk, Paul R. T.
    Sellan, Michael
    Olsen, Michael
    Schemitsch, Emil H.
    [J]. BULLETIN OF THE HOSPITAL FOR JOINT DISEASES, 2011, 69 : S5 - S11
  • [6] Metal-on-metal hip resurfacing
    Roberts, J
    Meek, RMD
    Roberts, P
    Grigoris, P
    [J]. SCOTTISH MEDICAL JOURNAL, 2005, 50 (01) : 10 - 12
  • [7] Effect of acetabular cup design on metal ion release in two designs of metal-on-metal hip resurfacing
    Cadossi, Matteo
    Tedesco, Giuseppe
    Savarino, Lucia
    Baldini, Nicola
    Mazzotti, Antonio
    Greco, Michelina
    Giannini, Sandro
    [J]. JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART B-APPLIED BIOMATERIALS, 2014, 102 (07) : 1595 - 1601
  • [8] Metal-on-Metal Hip Resurfacing
    Quesada, Mario J.
    Marker, David R.
    Mont, Michael A.
    [J]. JOURNAL OF ARTHROPLASTY, 2008, 23 (07): : 69 - 73
  • [9] Metal-on-metal hip resurfacing
    Ebied, A
    Journeaux, S
    [J]. CURRENT ORTHOPAEDICS, 2002, 16 (06): : 420 - 425
  • [10] The Effect of Acetabular Inclination on Metal Ion Levels Following Metal-on-Metal Hip Arthroplasty
    Emmanuel, Andrew R.
    Bergin, Karen M.
    Kelly, Gabrielle E.
    McCoy, Gerald F.
    Wozniak, Andrew P.
    Quinlan, John F.
    [J]. JOURNAL OF ARTHROPLASTY, 2014, 29 (01): : 186 - 191