Metal-on-metal bearings total hip arthroplasty: The cobalt and chromium ions release concern

被引:135
|
作者
Delaunay, C. [1 ]
Petit, I. [2 ]
Learmonth, I. D. [3 ]
Oger, P. [4 ]
Vendittoli, P. A. [5 ]
机构
[1] De Yvette Private Hosp, F-91160 Longjumeau, France
[2] Biomnis Biol Lab, F-94200 Ivry, France
[3] Southmead Hosp, Avon Orthopaed Ctr, Bristol Implant Res Ctr, Bristol BS10 5NB, Avon, England
[4] Versailles Hosp, Dept Orthopaed Surg, F-78150 Le Chesnay, France
[5] Univ Montreal, Maisonneuve Rosemont Hosp, Orthopaed Div, Montreal, PQ H1T 2M4, Canada
关键词
Total hip; arthroplasty; Metal-on-metal bearings; Hypersensitivity; Pseudotumors; Resurfacing; TOTAL KNEE ARTHROPLASTY; MINIMUM FOLLOW-UP; RESURFACING ARTHROPLASTY; WEAR DEBRIS; INFLAMMATORY PSEUDOTUMOR; SURFACE REPLACEMENT; PERIPHERAL-BLOOD; SERUM COBALT; IN-VITRO; OSTEOLYSIS;
D O I
10.1016/j.otsr.2010.05.008
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
With certain concerns recently reported on metal-on-metal bearing couples in total hip arthroplasty, this study's objective is to review the current knowledge concerning release of metal ions and its potential consequences. Each metal-on-metal implant presents different tribological properties. The analytical techniques for metals are accurate and the Co ion rates seem acceptable up to 2 mu g/L. A delayed type IV hypersensitivity reaction (atypical lymphocytic vasculitis-associated lesion [ALVAL]) may be the source of arthroplasty failure. Idiosyncratic, it remains unpredictable even using cutaneous tests and apparently is rare (0.3%). Today, there are no scientific or epidemiologic data supporting a risk of carcinogenesis or teratogenesis related to the use of a metal-on-metal bearings couple. Solid pseudotumors nearly exclusively are observed with resurfacing procedures, carrying a high annual revision rate in women under 40 years of age, occurring particularly in cases of acetabular malposition and with use of cast molded Cr-Co alloys. Osteolysis manifests through complete and progressive radiolucent lines or through cavitary lesions stemming from ALVAL-type alterations or impingement problems or implant incompatibility. The formation of wear debris exceeding the biological tolerance is possible with implant malposition, subluxation, and jamming of the femoral head in cases of cup deformity. Moreover, each implant presents different metal ion production; assessment of their performance and safety is required before their clinical use. With the knowledge available today, metal-on-metal bearing couples are contraindicated in cases of metal allergies or end stage renal dysfunction and small size resurfacing should cautiously be used. (C) 2010 Published by Elsevier Masson SAS.
引用
收藏
页码:894 / 904
页数:11
相关论文
共 50 条
  • [1] Presence of Cobalt and Chromium Ions in the Seminal Fluid of Young Patients With Metal-on-Metal Total Hip Arthroplasty
    Nikolaou, Vassilios S.
    Petit, Alain
    Zukor, David J.
    Papanastasiou, Constantine
    Huk, Olga L.
    Antoniou, John
    [J]. JOURNAL OF ARTHROPLASTY, 2013, 28 (01): : 161 - 167
  • [2] Cobalt and Chromium Ion Release After Large-Diameter Metal-on-Metal Total Hip Arthroplasty
    Hasegawa, Masahiro
    Yoshida, Kakunoshin
    Wakabayashi, Hiroki
    Sudo, Akihiro
    [J]. JOURNAL OF ARTHROPLASTY, 2012, 27 (06): : 990 - 996
  • [3] Metal-on-metal bearings in total hip arthroplasties: Influence of cobalt chromium ions on bacterial growth and biofilm formation
    Hosman, Anton H.
    van der Mei, Henny C.
    Bulstra, Sjoerd K.
    Busscher, Henk J.
    Neut, Danielle
    [J]. JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART A, 2009, 88A (03) : 711 - 716
  • [4] Metal-on-metal bearings in cementless primary total hip arthroplasty
    Delaunay, CP
    [J]. JOURNAL OF ARTHROPLASTY, 2004, 19 (08): : 35 - 40
  • [5] Cobalt and chromium concentrations in patients with metal-on-metal and other cementless total hip arthroplasty
    Maezawa, K
    Nozawa, M
    Hirose, T
    Matsuda, K
    Yasuma, M
    Shitoto, K
    Kurosawa, H
    [J]. ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2002, 122 (05) : 283 - 287
  • [6] Do cobalt and chromium levels predict osteolysis in metal-on-metal total hip arthroplasty?
    Renner, Lisa
    Schmidt-Braekling, Tom
    Faschingbauer, Martin
    Boettner, Friedrich
    [J]. ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2016, 136 (12) : 1657 - 1662
  • [7] Do cobalt and chromium levels predict osteolysis in metal-on-metal total hip arthroplasty?
    Lisa Renner
    Tom Schmidt-Braekling
    Martin Faschingbauer
    Friedrich Boettner
    [J]. Archives of Orthopaedic and Trauma Surgery, 2016, 136 : 1657 - 1662
  • [8] Cobalt and chromium concentrations in patients with metal-on-metal and other cementless total hip arthroplasty
    Katsuhiko Maezawa
    Masahiko Nozawa
    Tomohiko Hirose
    Keiji Matsuda
    Motoo Yasuma
    Katsuo Shitoto
    Hisashi Kurosawa
    [J]. Archives of Orthopaedic and Trauma Surgery, 2002, 122 : 283 - 287
  • [9] Metal release from hip prostheses: biological monitoring of cobalt and chromium in patients with metal-on-metal hip arthroplasty
    Torra, Merce
    Sandalinas, Silvia
    Martin, Mayte
    Nogue, Santiago
    [J]. TRACE ELEMENTS AND ELECTROLYTES, 2017, 34 (01) : 1 - 4
  • [10] Exposure to chromium, cobalt and molybdenum from metal-on-metal total hip replacement and hip resurfacing arthroplasty
    Witzleb, Wolf-Christoph
    Ziegler, Joerg
    Krummenauer, Frank
    Neumeister, Volker
    Guenther, Klaus-Peter
    [J]. ACTA ORTHOPAEDICA, 2006, 77 (05) : 697 - 705