Performance Analysis of Harmonic-Reduced Modified PUC Multi-Level Inverter Based on an MPC Algorithm

被引:5
|
作者
Krishnamoorthy, Umapathi [1 ]
Pitchaikani, Ushaa [2 ]
Rusu, Eugen [3 ]
Fayek, Hady H. [4 ]
机构
[1] KIT Kalaignarkarunanidhi Inst Technol, Dept Biomed Engn, Coimbatore 641402, India
[2] M Kumarasamy Coll Engn, Dept Elect & Elect Engn, Karur 639113, India
[3] Dunarea de Jos Univ Galati, Fac Engn, Dept Mech Engn, 47 Domneasca St, Galati 800008, Romania
[4] Heliopolis Univ, Electromech Engn Dept, Salam 11785, Egypt
关键词
packed U-cell (PUC); inverter; multi-level inverter (MLI); model predictive control (MPC); total harmonic distortion (THD); harmonic reduction; CONVERTERS; TOPOLOGY; DESIGN;
D O I
10.3390/inventions8040090
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Renewable and distributed energy generation includes wind turbines, fuel cells, solar cells, and batteries. These distributed energy sources need special power converters in order to connect them to the grid and make the generated power available for public use. Solar energy is the most readily available energy source; hence, if utilized properly, it can power up both domestic and industrial loads. Solar cells produce DC power, and this should be converted to an AC source with the help of inverters. A multi-level inverter for an application is selected based on a trade-off between cost, complexity, losses, and total harmonic distortion (THD). A packed U-cell (PUC) topology is composed of power switches and voltage sources connected in a series-parallel fashion. This basic unit can be extended to a greater number of output voltage levels. The significance of this design is the reduced use of power switches, gate drivers, protection circuits, and capacitors. The converter presented in this paper is a 31-level topology switched by a variable switching frequency-based model predictive controller that helps in achieving optimal output with reduced harmonics to a great extent. The gate driver circuit is also optimized in terms of power consumption and size complexity. A comparison of the 9-level and the 31-level PUC inverters is carried out to study the impact of the number of levels on the total harmonic distortion. The simulation results depict that the total harmonic distortion (THD) for a nominal modulation index of 0.8 is 11.54% and 3.27% for the 9-level multi-level inverter (MLI) and the 31-level modified packed U-cell multi-level inverter (MPUC-MLI), respectively. The reduction in THD is attributed to the increased number of steps in the output when using the model predictive controller.
引用
收藏
页数:22
相关论文
共 50 条
  • [31] Analysis and application of inventive selective harmonic elimination strategy to eliminate high order harmonic from asymmetrical multi-level inverter
    Falehi, Ali Darvish
    MULTIDIMENSIONAL SYSTEMS AND SIGNAL PROCESSING, 2020, 31 (02) : 411 - 429
  • [32] Analysis and application of inventive selective harmonic elimination strategy to eliminate high order harmonic from asymmetrical multi-level inverter
    Ali Darvish Falehi
    Multidimensional Systems and Signal Processing, 2020, 31 : 411 - 429
  • [33] Developing a Generalized Multi-Level Inverter with Reduced Number of Power Electronics Components
    Shayeghi, Hossein
    Seifi, Ali
    Hosseinpour, Majid
    Bizon, Nicu
    SUSTAINABILITY, 2022, 14 (09)
  • [34] Design and analysis of a new multi-level inverter topology with a reduced number of switches and controlled by PDPWM technique
    Chakir, Fatima
    EL Magri, Abdelmounime
    Lajouad, Rachid
    Kissaoui, Mohamed
    Chakir, Mostafa
    Bouattane, Omar
    INTERNATIONAL JOURNAL OF ELECTRICAL AND COMPUTER ENGINEERING SYSTEMS, 2023, 14 (05) : 593 - 600
  • [35] Multiple population genetic algorithm based on multi-band SHEPWM control technology for multi-level inverter
    Ye, Manyuan
    Zhou, Qiqi
    Cai, Hong
    Li, Song
    Diangong Jishu Xuebao/Transactions of China Electrotechnical Society, 2015, 30 (16): : 111 - 119
  • [36] The analysis of conduction and switching losses in multi-level inverter system
    Kim, TJ
    Kang, DW
    Lee, YH
    Hyun, DS
    PESC 2001: 32ND ANNUAL POWER ELECTRONICS SPECIALISTS CONFERENCE, VOLS 1-4, CONFERENCE PROCEEDINGS, 2001, : 1363 - 1368
  • [37] Analysis of multi-level threshold handoff algorithm
    Kim, YI
    Lee, KJ
    Chin, YO
    IEEE GLOBECOM 1996 - CONFERENCE RECORD, VOLS 1-3: COMMUNICATIONS: THE KEY TO GLOBAL PROSPERITY, 1996, : 1141 - 1145
  • [38] Selective harmonic elimination in multi-level inverter with zig-zag connection transformers
    Young, Chung-Ming
    Wu, Sheng-Feng
    IET POWER ELECTRONICS, 2014, 7 (04) : 876 - 885
  • [39] Multi-level Scheduling Algorithm Based on Storm
    Wang, Jie
    Hang, Siguang
    Liu, Jiwei
    Chen, Weihao
    Hou, Gang
    KSII TRANSACTIONS ON INTERNET AND INFORMATION SYSTEMS, 2016, 10 (03): : 1091 - 1110
  • [40] Application of memetic algorithm for selective harmonic elimination in multi-level inverters
    Kumle, Alireza Niknam
    Fathi, Seyed Hamid
    Jabbarvaziri, Faramarz
    Jamshidi, Mehdi
    Yazdi, Seyed Saeed Heidari
    IET POWER ELECTRONICS, 2015, 8 (09) : 1733 - 1739