Performance Analysis of Harmonic-Reduced Modified PUC Multi-Level Inverter Based on an MPC Algorithm

被引:5
|
作者
Krishnamoorthy, Umapathi [1 ]
Pitchaikani, Ushaa [2 ]
Rusu, Eugen [3 ]
Fayek, Hady H. [4 ]
机构
[1] KIT Kalaignarkarunanidhi Inst Technol, Dept Biomed Engn, Coimbatore 641402, India
[2] M Kumarasamy Coll Engn, Dept Elect & Elect Engn, Karur 639113, India
[3] Dunarea de Jos Univ Galati, Fac Engn, Dept Mech Engn, 47 Domneasca St, Galati 800008, Romania
[4] Heliopolis Univ, Electromech Engn Dept, Salam 11785, Egypt
关键词
packed U-cell (PUC); inverter; multi-level inverter (MLI); model predictive control (MPC); total harmonic distortion (THD); harmonic reduction; CONVERTERS; TOPOLOGY; DESIGN;
D O I
10.3390/inventions8040090
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Renewable and distributed energy generation includes wind turbines, fuel cells, solar cells, and batteries. These distributed energy sources need special power converters in order to connect them to the grid and make the generated power available for public use. Solar energy is the most readily available energy source; hence, if utilized properly, it can power up both domestic and industrial loads. Solar cells produce DC power, and this should be converted to an AC source with the help of inverters. A multi-level inverter for an application is selected based on a trade-off between cost, complexity, losses, and total harmonic distortion (THD). A packed U-cell (PUC) topology is composed of power switches and voltage sources connected in a series-parallel fashion. This basic unit can be extended to a greater number of output voltage levels. The significance of this design is the reduced use of power switches, gate drivers, protection circuits, and capacitors. The converter presented in this paper is a 31-level topology switched by a variable switching frequency-based model predictive controller that helps in achieving optimal output with reduced harmonics to a great extent. The gate driver circuit is also optimized in terms of power consumption and size complexity. A comparison of the 9-level and the 31-level PUC inverters is carried out to study the impact of the number of levels on the total harmonic distortion. The simulation results depict that the total harmonic distortion (THD) for a nominal modulation index of 0.8 is 11.54% and 3.27% for the 9-level multi-level inverter (MLI) and the 31-level modified packed U-cell multi-level inverter (MPUC-MLI), respectively. The reduction in THD is attributed to the increased number of steps in the output when using the model predictive controller.
引用
收藏
页数:22
相关论文
共 50 条
  • [41] Harmonic Optimization in Multi-Level Inverters using Harmony Search Algorithm
    Majidi, B.
    Baghaee, H. R.
    Gharehpetian, G. B.
    Milimonfared, J.
    Mirsalim, M.
    2008 IEEE 2ND INTERNATIONAL POWER AND ENERGY CONFERENCE: PECON, VOLS 1-3, 2008, : 646 - 650
  • [42] A Modified Multi-Level Inverter System for Grid-Tied DES Applications
    Ahmed, Sajjad
    Saqib, Muhammad Asghar
    Kashif, Syed Abdul Rahman
    Hashmi, Khurram
    Aymen, Flah
    AboRas, Kareem M.
    Jasinska, Laura
    Leonowicz, Zbigniew
    SUSTAINABILITY, 2022, 14 (24)
  • [43] A Modified Single-Phase Multi-Level Inverter with Increased Number of Steps
    Esmaeili, Fatemeh
    Varesi, Kazem
    2019 IRANIAN CONFERENCE ON RENEWABLE ENERGY & DISTRIBUTED GENERATION (ICREDG), 2019,
  • [44] Simple harmonic analysis method for multi-carrier PWM techniques using output phase voltage in multi-level inverter
    Kang, DW
    Hyun, DS
    IEE PROCEEDINGS-ELECTRIC POWER APPLICATIONS, 2005, 152 (02): : 157 - 165
  • [45] Multi-level Segmentation of Fruits Using Modified Firefly Algorithm
    Chaturvedi, Rekha
    Sharma, Abhay
    Bhargava, Anuja
    Rajpurohit, Jitendra
    Gothwal, Pushpa
    FOOD ANALYTICAL METHODS, 2022, 15 (11) : 2891 - 2900
  • [46] Analysis of multi-carrier PWM methods for asymmetric multi-level inverter
    Aghdam, A. G. Hosseini
    Fathi, S. H.
    Gharehpetian, G. B.
    ICIEA 2008: 3RD IEEE CONFERENCE ON INDUSTRIAL ELECTRONICS AND APPLICATIONS, PROCEEDINGS, VOLS 1-3, 2008, : 2057 - 2062
  • [47] Influence of crossover methods used by genetic algorithm-based heuristic to solve the selective harmonic equations (SHE) in multi-level voltage source inverter
    Sangeetha, S.
    Jeevananthan, S.
    SADHANA-ACADEMY PROCEEDINGS IN ENGINEERING SCIENCES, 2015, 40 (08): : 2389 - 2410
  • [48] Design of modified long short-term memory-based zebra optimization algorithm for limiting the issue of SHEPWM in multi-level inverter
    Krithiga, G.
    Senthilkumar, S.
    Alharbi, Mohammed
    Mangaiyarkarasi, S. P.
    SCIENTIFIC REPORTS, 2024, 14 (01):
  • [49] Optimization Based Selective Harmonic Elimination in Multi-Level Inverters
    Sahu, Neha
    Londhe, Narendra D.
    2017 NATIONAL POWER ELECTRONICS CONFERENCE (NPEC), 2017, : 325 - 329
  • [50] Design of reduced switch count multi-level inverter based electric spring for critical load voltage stability
    Raghava, B. V. S.
    Satputaley, R. J.
    Rao, S. Manmadha
    ENERGY REPORTS, 2023, 9 : 290 - 295