Consecutive spectrophotometric determination of phosphate and silicate in a sequential injection lab-at-valve flow system

被引:3
|
作者
Vishnikin, Andriy [1 ,2 ]
Hedjazi, Mehieddine [2 ]
Al-Shwaiyat, Mohammed [3 ]
Skok, Arina [1 ]
Bazel, Yaroslav [1 ]
机构
[1] Pavol Jozef Safarik Univ, Fac Sci, Dept Analyt Chem, Kosice 04011, Slovakia
[2] Oles Honchar Dnipro Natl Univ, Chem Fac, Dept Analyt Chem, UA-49010 Dnipro, Ukraine
[3] Al Balqa Appl Univ, Zarka Univ Coll, Dept Basic & Appl Sci, Al Salt 19117, Jordan
关键词
Sequential injection lab-at-valve analysis; Phosphate; Silicate; Consecutive determination; ION ASSOCIATE; TRACE DETERMINATION; NATURAL-WATERS; ASCORBIC-ACID; EXTRACTION; 12-MOLYBDOPHOSPHATE; ORTHOPHOSPHATE;
D O I
10.1016/j.aca.2023.341464
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A new highly sensitive and selective sequential injection lab-at-valve spectrophotometric method for the consecutive determination of silicate and phosphate is described. The proposed method is based on the formation of specific ion-association complexes (IAs) of 12-heteropolymolybdates of phosphorus and silicon (12-MSC) with Astra Phloxine. The addition of an external reaction chamber (RC) to the SIA manifold made it possible to significantly improve the conditions for the formation of the analytical form used. The formation of the IA took place in the RC; the solution is mixed by passing an air flow through it. The interfering effect on the determi-nation of phosphate from silicate was completely eliminated by choosing an acidity at which the rate of 12-MSC formation is very low. The use of secondary acidification in the determination of silicate led to the complete exclusion of the influence of phosphate. The tolerable ratio of phosphate to silicate and vice versa is about 100 -times, which allows the analysis of most real samples without the use of masking agents or complex separation steps. The determination ranges are 3.0-60 & mu;g L-1 for phosphate as P(V) and 2.8-56 & mu;g L-1 for silicate as Si(IV) at a throughput of 5 samples h-1. The detection limits are 5.0 and 3.8 & mu;g L-1 for phosphate and silicate, respectively. Silicate and phosphate were determined in the tap water, river water, mineral water, main water of the Krivoy Rog (Ukraine) region, and the certified reference material of carbon steel.
引用
收藏
页数:9
相关论文
共 50 条
  • [41] Development of sequential injection-lab-at-valve (SI-LAV) micro-extraction instrumentation for the spectrophotometric determination of an anionic surfactant
    Burakham, R
    Jakmunee, J
    Grudpan, K
    ANALYTICAL SCIENCES, 2006, 22 (01) : 137 - 140
  • [42] Micro sequential injection: environmental monitoring of nitrogen and phosphate in water using a "Lab-on-Valve" system furnished with a microcolumn
    Wu, CH
    Ruzicka, J
    ANALYST, 2001, 126 (11) : 1947 - 1952
  • [43] SPECTROPHOTOMETRIC DETERMINATION OF CALCIUM WITH A FLOW-INJECTION SYSTEM
    NAKAGAWA, G
    WADA, H
    WEI, C
    ANALYTICA CHIMICA ACTA, 1983, 145 (JAN) : 135 - 141
  • [44] Determination of cadmium in a sequential injection lab-on-valve system with voltammetric detection using a morin modified electrode
    Wang, Yang
    Liu, Zaiqing
    Tang, Jie
    Yao, Guojun
    Hu, Xiaoya
    ANALYTICAL METHODS, 2011, 3 (03) : 731 - 737
  • [45] FLOW-INJECTION SPECTROPHOTOMETRIC DETERMINATION OF PHOSPHATE USING CRYSTAL VIOLET
    BURNS, DT
    CHIMPALEE, D
    CHIMPALEE, N
    ITTIPORNKUL, S
    ANALYTICA CHIMICA ACTA, 1991, 254 (1-2) : 197 - 200
  • [46] Potentiometric measurements in sequential injection analysis lab-on-valve (SIA-LOV) flow-system
    Kikas, Timo
    Ivaska, Ari
    TALANTA, 2007, 71 (01) : 160 - 164
  • [47] Determination of Albumin, Glucose, and Creatinine Employing a Single Sequential Injection Lab-at-Valve with Mono-Segmented Flow System Enabling In-Line Dilution, In-Line Single-Standard Calibration, and In-Line Standard Addition
    Kiwfo, Kanokwan
    Wongwilai, Wasin
    Sakai, Tadao
    Teshima, Norio
    Grudpan, Kate
    MOLECULES, 2020, 25 (07):
  • [48] Microsequential injection lab-on-valve system for the spectrophotometric bi-parametric determination of iron and copper in natural waters
    Gonzalez, Alba
    Mesquita, Raquel B. R.
    Avivar, Jessica
    Moniz, Tania
    Rangel, Maria
    Cerda, Victor
    Rangel, Antonio O. S. S.
    TALANTA, 2017, 167 : 703 - 708
  • [49] Sequential injection lab-on-valve procedure for the determination of amantadine using potentiometric methods
    Amorim, C. G.
    Araujo, A. N.
    Montenegro, M. C. B. S. M.
    Silva, V. L.
    ELECTROANALYSIS, 2007, 19 (21) : 2227 - 2233
  • [50] Reversed flow injection and sandwich sequential injection methods for the spectrophotometric determination of copper(II) with cuprizone
    Rumori, P
    Cerdà, V
    ANALYTICA CHIMICA ACTA, 2003, 486 (02) : 227 - 235