Micro sequential injection: environmental monitoring of nitrogen and phosphate in water using a "Lab-on-Valve" system furnished with a microcolumn

被引:46
|
作者
Wu, CH [1 ]
Ruzicka, J [1 ]
机构
[1] Univ Washington, Dept Chem, Seattle, WA 98195 USA
关键词
D O I
10.1039/b104305f
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A "Lab-on-Valve" manifold operated in the micro sequential injection (mu SI) mode was adopted to accommodate EPA-approved methods for spectrophotometric determinations of nitrate, nitrite and orthophosphate in the ppb (N or P) concentration range. A computer programmable mu SI protocol, utilizing stopped-flow within a copperized Cd-foil filled microcolumn was developed for nitrate reduction to nitrite with subsequent colorimetric measurement, yielding concentration ranges for nitrate of 100.0-4000.0 ppb (N) and for nitrite of 30.0-4000.0 ppb (N) and linear calibration responses of r(2) = 0.9999 for nitrate and 0.9995 for nitrite. Using a stopped-flow reaction rate measurement, phosphate was determined in the range 1.0-30.0 ppb (P) with a calibration response of r(2) = 0.9997. The technical improvement of this methodology, apart from micro miniaturization, is the use of the stopped-flow technique, that resulted in improved detection limits and allowed reagent consumption to be reduced 1500-fold compared with conventional procedure while the amount of metallic cadmium was reduced 20-fold compared with the EPA-approved continuous-flow assay.
引用
收藏
页码:1947 / 1952
页数:6
相关论文
共 50 条
  • [1] Micro sequential injection: fermentation monitoring of ammonia, glycerol, glucose, and free iron using the novel lab-on-valve system
    Wu, CH
    Scampavia, L
    Ruzicka, J
    Zamost, B
    ANALYST, 2001, 126 (03) : 291 - 297
  • [2] Micro sequential injection: automated insulin derivatization and separation using a lab-on-valve capillary electrophoresis system
    Wu, CH
    Scampavia, L
    Ruzicka, J
    ANALYST, 2003, 128 (09) : 1123 - 1130
  • [3] Sequential Injection Lab-on-Valve System for the Determination of the Activity of Peroxidase in Vegetables
    Vidigal, Susana S. M. P.
    Toth, Ildiko V.
    Rangel, Antonio O. S. S.
    JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2010, 58 (04) : 2071 - 2075
  • [4] A green analytical method for rapid determination of pectin degree of esterification using micro sequential injection lab-on-valve system
    Naghshineh, Mahsa
    Larsen, Jan
    Georgiou, Constantinos
    Olsen, Karsten
    FOOD CHEMISTRY, 2016, 204 : 513 - 520
  • [5] Determination of dissolved zinc in seawater using micro-Sequential Injection lab-on-valve with fluorescence detection
    Grand, Maxime
    Oliveira, Hugo M.
    Ruzicka, Jaromir
    Measures, Christopher
    ANALYST, 2011, 136 (13) : 2747 - 2755
  • [6] Sequential injection lab-on-valve system for the on-line monitoring of hydrogen peroxide in lens care solutions
    Vidigal, Susana S. M. P.
    Toth, Ildiko V.
    Rangel, Antonio O. S. S.
    MICROCHEMICAL JOURNAL, 2009, 91 (02) : 197 - 201
  • [7] Accelerated micro-sequential injection in lab-on-valve format, applied to enzymatic assays
    Chen, Y
    Ruzicka, J
    ANALYST, 2004, 129 (07) : 597 - 601
  • [8] An electrochemical assay for the determination of Se (IV) in a sequential injection lab-on-valve system
    Wang, Yang
    Liu, Zaiqing
    Yao, Guojun
    Zhu, Peihua
    Hu, Xiaoya
    Yang, Chun
    Xu, Qin
    ANALYTICA CHIMICA ACTA, 2009, 649 (01) : 75 - 79
  • [9] Sequential injection lab-on-valve procedure for the determination of amantadine using potentiometric methods
    Amorim, C. G.
    Araujo, A. N.
    Montenegro, M. C. B. S. M.
    Silva, V. L.
    ELECTROANALYSIS, 2007, 19 (21) : 2227 - 2233
  • [10] Determination of cadmium in a sequential injection lab-on-valve system with voltammetric detection using a morin modified electrode
    Wang, Yang
    Liu, Zaiqing
    Tang, Jie
    Yao, Guojun
    Hu, Xiaoya
    ANALYTICAL METHODS, 2011, 3 (03) : 731 - 737