Sequential injection lab-on-valve procedure for the determination of amantadine using potentiometric methods

被引:20
|
作者
Amorim, C. G. [1 ]
Araujo, A. N. [1 ]
Montenegro, M. C. B. S. M. [1 ]
Silva, V. L. [1 ]
机构
[1] Univ Porto, Dept Quim Fis, REQUIMTE, F Farm, P-4099030 Oporto, Portugal
关键词
lab-on-valve; ion selective electrodes; potentiometry; amantadine; cyclodextrin;
D O I
10.1002/elan.200703973
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Amantadine potentiometric detectors were developed, evaluated and incorporated in a SIA-LOV manifold in order to accomplish the control of pharmaceutical formulations and urine. The electrodes incorporate a-cyclodextrin as ionophore, dibutyl phthalate or 2-fluorophenyl 2-nitrophenyl ether as plasticizers and potassium tetrakis[3,5-bis-(trifluoromethyl)phenyl]borate (KTFPB) as cationic additive. The slope increased from 61.2 to 63.8 mV decade(-1) and the practical limit of detection from 2.6 x 10(-6) mol L-1 to 2.5 x 10(-5) mol L-1 when the plasticizer was changed from 2-fluorophenyl 2-nitrophenyl ether to dibutyl phthalate. When incorporated in the flow-manifold the membranes composed by dibutyl phthalate or with 2-fluorophenyl 2-nitrophenyl ether presented slopes and a practical limit of detection of 69.8 mV decade(-1) and 1.5 x 10(-4) mol L-1 or 73.7 mV decade(-1) and 5.4 x 10(-5) mol L-1, respectively. The electrode presented stable responses for over a year, and were highly selective concerning the representative species of the two sample matrices assayed as interferents. Comparison of obtained results with those provided by reference methods and recovery assays, revealed adequate accuracy for control assays.
引用
收藏
页码:2227 / 2233
页数:7
相关论文
共 50 条
  • [1] Automated lab-on-valve sequential injection ELISA for determination of carbamazepine
    Ramos, Ines I.
    Carl, Peter
    Schneider, Rudolf J.
    Segundo, Marcela A.
    ANALYTICA CHIMICA ACTA, 2019, 1076 : 91 - 99
  • [2] Exploiting sequential injection analysis with lab-on-valve and miniaturized potentiometric detection - Epinephrine determination in pharmaceutical products
    Amorim, C. G.
    Araujo, A. N.
    Montenegro, M. C. B. S. M.
    TALANTA, 2007, 72 (04) : 1255 - 1260
  • [3] The development of sequential injection analysis coupled with lab-on-valve for copper determination
    Leelasattarathkul, Tapparath
    Liawruangrath, Saisunee
    Rayanakorn, Mongkon
    Oungpipat, Winai
    Liawruangrath, Boonsom
    TALANTA, 2006, 70 (03) : 656 - 660
  • [4] Sequential Injection Lab-on-Valve System for the Determination of the Activity of Peroxidase in Vegetables
    Vidigal, Susana S. M. P.
    Toth, Ildiko V.
    Rangel, Antonio O. S. S.
    JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2010, 58 (04) : 2071 - 2075
  • [5] An electrochemical assay for the determination of Se (IV) in a sequential injection lab-on-valve system
    Wang, Yang
    Liu, Zaiqing
    Yao, Guojun
    Zhu, Peihua
    Hu, Xiaoya
    Yang, Chun
    Xu, Qin
    ANALYTICA CHIMICA ACTA, 2009, 649 (01) : 75 - 79
  • [6] Sequential injection lab-on-valve: the third generation of flow injection analysis
    Wang, JH
    Hansen, EH
    TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2003, 22 (04) : 225 - 231
  • [7] Determination of dissolved zinc in seawater using micro-Sequential Injection lab-on-valve with fluorescence detection
    Grand, Maxime
    Oliveira, Hugo M.
    Ruzicka, Jaromir
    Measures, Christopher
    ANALYST, 2011, 136 (13) : 2747 - 2755
  • [8] Potentiometric measurements in sequential injection analysis lab-on-valve (SIA-LOV) flow-system
    Kikas, Timo
    Ivaska, Ari
    TALANTA, 2007, 71 (01) : 160 - 164
  • [9] Determination of cadmium in a sequential injection lab-on-valve system with voltammetric detection using a morin modified electrode
    Wang, Yang
    Liu, Zaiqing
    Tang, Jie
    Yao, Guojun
    Hu, Xiaoya
    ANALYTICAL METHODS, 2011, 3 (03) : 731 - 737
  • [10] Sequential injection lab-on-valve simultaneous spectrophotometric determination of trace amounts of copper and iron
    Ohno, S
    Teshima, N
    Sakai, T
    Grudpan, K
    Polasek, M
    TALANTA, 2006, 68 (03) : 527 - 534