Consecutive spectrophotometric determination of phosphate and silicate in a sequential injection lab-at-valve flow system

被引:3
|
作者
Vishnikin, Andriy [1 ,2 ]
Hedjazi, Mehieddine [2 ]
Al-Shwaiyat, Mohammed [3 ]
Skok, Arina [1 ]
Bazel, Yaroslav [1 ]
机构
[1] Pavol Jozef Safarik Univ, Fac Sci, Dept Analyt Chem, Kosice 04011, Slovakia
[2] Oles Honchar Dnipro Natl Univ, Chem Fac, Dept Analyt Chem, UA-49010 Dnipro, Ukraine
[3] Al Balqa Appl Univ, Zarka Univ Coll, Dept Basic & Appl Sci, Al Salt 19117, Jordan
关键词
Sequential injection lab-at-valve analysis; Phosphate; Silicate; Consecutive determination; ION ASSOCIATE; TRACE DETERMINATION; NATURAL-WATERS; ASCORBIC-ACID; EXTRACTION; 12-MOLYBDOPHOSPHATE; ORTHOPHOSPHATE;
D O I
10.1016/j.aca.2023.341464
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A new highly sensitive and selective sequential injection lab-at-valve spectrophotometric method for the consecutive determination of silicate and phosphate is described. The proposed method is based on the formation of specific ion-association complexes (IAs) of 12-heteropolymolybdates of phosphorus and silicon (12-MSC) with Astra Phloxine. The addition of an external reaction chamber (RC) to the SIA manifold made it possible to significantly improve the conditions for the formation of the analytical form used. The formation of the IA took place in the RC; the solution is mixed by passing an air flow through it. The interfering effect on the determi-nation of phosphate from silicate was completely eliminated by choosing an acidity at which the rate of 12-MSC formation is very low. The use of secondary acidification in the determination of silicate led to the complete exclusion of the influence of phosphate. The tolerable ratio of phosphate to silicate and vice versa is about 100 -times, which allows the analysis of most real samples without the use of masking agents or complex separation steps. The determination ranges are 3.0-60 & mu;g L-1 for phosphate as P(V) and 2.8-56 & mu;g L-1 for silicate as Si(IV) at a throughput of 5 samples h-1. The detection limits are 5.0 and 3.8 & mu;g L-1 for phosphate and silicate, respectively. Silicate and phosphate were determined in the tap water, river water, mineral water, main water of the Krivoy Rog (Ukraine) region, and the certified reference material of carbon steel.
引用
收藏
页数:9
相关论文
共 50 条
  • [21] A sequential injection system for spectrophotometric determination of ketoconazole
    Fraihat, Safwan M.
    MAEJO INTERNATIONAL JOURNAL OF SCIENCE AND TECHNOLOGY, 2014, 8 (03) : 232 - 239
  • [22] An electrochemical assay for the determination of Se (IV) in a sequential injection lab-on-valve system
    Wang, Yang
    Liu, Zaiqing
    Yao, Guojun
    Zhu, Peihua
    Hu, Xiaoya
    Yang, Chun
    Xu, Qin
    ANALYTICA CHIMICA ACTA, 2009, 649 (01) : 75 - 79
  • [23] On-line liquid phase micro-extraction based on drop-in-plug sequential injection lab-at-valve platform for metal determination
    Mitani, Constantina
    Anthemidis, Aristidis N.
    ANALYTICA CHIMICA ACTA, 2013, 771 : 50 - 55
  • [24] Sequential injection lab-on-valve: the third generation of flow injection analysis
    Wang, JH
    Hansen, EH
    TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2003, 22 (04) : 225 - 231
  • [25] Spectrophotometric determination of purine alkaloids by flow injection and sequential injection analysis
    L. K. Shpigun
    E. Yu. Andryukhina
    Ya. V. Shushenachev
    Journal of Analytical Chemistry, 2015, 70 : 926 - 935
  • [26] Spectrophotometric determination of purine alkaloids by flow injection and sequential injection analysis
    Shpigun, L. K.
    Andryukhina, E. Yu.
    Shushenachev, Ya. V.
    JOURNAL OF ANALYTICAL CHEMISTRY, 2015, 70 (08) : 926 - 935
  • [27] Automated lab-on-valve sequential injection ELISA for determination of carbamazepine
    Ramos, Ines I.
    Carl, Peter
    Schneider, Rudolf J.
    Segundo, Marcela A.
    ANALYTICA CHIMICA ACTA, 2019, 1076 : 91 - 99
  • [28] Simultaneous determination of phosphate and silicate in waste water by sequential injection analysis
    MasTorres, F
    Munoz, A
    Estela, JM
    Cerda, V
    ANALYST, 1997, 122 (10) : 1033 - 1038
  • [29] Determination of orciprenaline using a flow injection analysis system with sequential potentiometric and spectrophotometric detection
    El Nashar, Rasha Mohamed
    ANALYTICAL LETTERS, 2008, 41 (06) : 949 - 964
  • [30] Sequential flow injection determination of iodate and periodate with spectrophotometric detection
    Ensafi, AA
    Chamjangali, MA
    SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 2003, 59 (12) : 2897 - 2903