Design and evaluation of a hip prosthesis simulator: A technical note

被引:3
|
作者
Fanous, Amir [1 ]
Botros, Michael [1 ]
Gholizadeh, Hossein [1 ,2 ]
Baddour, Natalie [1 ]
Lemaire, Edward D. [2 ,3 ]
机构
[1] Univ Ottawa, Dept Mech Engn, Fac Engn, 505 Smyth Rd, Ottawa, ON K1H 8M2, Canada
[2] Ottawa Hosp, Ottawa Hosp Res Inst, Rehabil Ctr, Ottawa, ON, Canada
[3] Univ Ottawa, Fac Med, Ottawa, ON, Canada
关键词
amputation; prosthesis; hip disarticulation; hemipelvectomy; rehabilitation; simulator; artificial limb; ENERGY-EXPENDITURE; DISARTICULATION; WALKING; GAIT;
D O I
10.1097/PXR.0000000000000208
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
People with a limb loss at the level of the hip or pelvis have the most difficulty returning to walking compared with those with a lower amputation. This is because their prosthesis must replace the hip, knee, and ankle joints. An adjustable hip-disarticulation/hemipelvectomy prosthesis simulator that allows able-bodied individuals to wear and assess a prosthesis can help researchers and manufacturers when designing new prosthetic components (ie, hip joints). SolidWorks computer-aided design software was used to design and simulate an adapter that can connect prosthetic components to an off-the-shelf hip abduction orthosis. The adapter was made of 1020 stainless steel and aluminium 6061-T3 with a yield strength of 276 MPa. To confirm that this adapter is strong and safe for ambulation, mechanical testing was performed using an INSTRON machine. The maximum loads generated in any activity were chosen according to the International Organization for Standardization 15032:2000 standard for hip disarticulation external prostheses. The designed adapter allowed frontal, lateral, or distal mounting of different prosthetic hip joints. Mechanical testing confirmed that the new adapter can withstand forces and moments experienced during ambulation. The hip disarticulation/hemipelvectomy prosthesis simulator is easy to use and adjustable based on each person's height and pelvic width. Furthermore, this simulator would assist rehabilitation practitioners in experiencing the use of hip-level prostheses and give them a better understanding of people using such technologies. The next step in this project is to evaluate able-bodied participant gait while using this hip simulator prosthesis with different hip joints.
引用
收藏
页码:443 / 446
页数:4
相关论文
共 50 条
  • [31] Technical note: Comparison of metal-on-metal hip simulator wear measured by gravimetric, CMM and optical profiling methods
    Alberts, L. Russell
    Martinez-Nogues, Vanesa
    Cook, Richard Baker
    Maul, Christian
    Bills, Paul
    Racasan, R.
    Stolz, Martin
    Wood, Robert J. K.
    SURFACE TOPOGRAPHY-METROLOGY AND PROPERTIES, 2018, 6 (01):
  • [32] RADIOLUCENT PROSTHESIS OF MESH-REINFORCED ACRYLIC - TECHNICAL NOTE
    LAKE, PA
    MORIN, MA
    PITTS, FW
    JOURNAL OF NEUROSURGERY, 1970, 32 (05) : 597 - &
  • [33] Technical note: The use of a silicone prosthesis for the closure of a tracheoesophageal fistula
    Holmes, Matthew J., V
    George, Ajith
    CLINICAL OTOLARYNGOLOGY, 2022, 47 (03) : 483 - 485
  • [34] Treatment of interprosthetic femoral fractures with an interposition prosthesis A technical note
    Citak, Mustafa
    Klatte, Till Orla
    Kendoff, Daniel
    Haasper, Carl
    Gehrke, Thorsten
    Gebauer, Matthias
    ACTA ORTHOPAEDICA, 2013, 84 (03) : 326 - 327
  • [35] DESIGN AND TESTING OF A FLEXIBLE HIP-PROSTHESIS
    DJERF, K
    IVARSSON, I
    JACOBSSON, SA
    CLINICAL BIOMECHANICS, 1994, 9 (06) : 375 - 376
  • [36] A physical simulator for endoscopic endonasal drilling techniques: technical note
    Tai, Bruce L.
    Wang, Anthony C.
    Joseph, Jacob R.
    Wang, Page I.
    Sullivan, Stephen E.
    McKean, Erin L.
    Shih, Albert J.
    Rooney, Deborah M.
    JOURNAL OF NEUROSURGERY, 2016, 124 (03) : 811 - 816
  • [37] Design of biped hip simulator using SolidWorks
    Zainudin, M. R.
    Yahya, A.
    Fazli, M. I. M.
    Syahrom, A.
    Harun, F. K. C.
    Nazarudin, M. S.
    INTERNATIONAL CONFERENCE ON APPLICATIONS AND DESIGN IN MECHANICAL ENGINEERING (ICADME 2017), 2017, 908
  • [38] CT evaluation of total HIP prosthesis infection
    Jacquier, A
    Champsaur, P
    Vidal, V
    Stein, A
    Monnet, O
    Drancourt, M
    Argenson, JN
    Raoult, D
    Moulin, G
    Bartoli, JM
    JOURNAL DE RADIOLOGIE, 2004, 85 (12): : 2005 - 2012
  • [39] Technical note: validation of a motion analysis system for measuring the relative motion of the intermediate component of a tripolar total hip arthroplasty prosthesis
    Chen, QS
    Lazennec, JY
    Guyen, O
    Kinbrum, A
    Berry, DJ
    An, KN
    MEDICAL ENGINEERING & PHYSICS, 2005, 27 (06) : 505 - 512
  • [40] EASY EXTRACTION OF A FRACTURED HIP SCREW - A TECHNICAL NOTE
    HUSTED, H
    MERRILD, U
    ACTA ORTHOPAEDICA SCANDINAVICA, 1994, 65 (06): : 651 - 651