Design and evaluation of a hip prosthesis simulator: A technical note

被引:3
|
作者
Fanous, Amir [1 ]
Botros, Michael [1 ]
Gholizadeh, Hossein [1 ,2 ]
Baddour, Natalie [1 ]
Lemaire, Edward D. [2 ,3 ]
机构
[1] Univ Ottawa, Dept Mech Engn, Fac Engn, 505 Smyth Rd, Ottawa, ON K1H 8M2, Canada
[2] Ottawa Hosp, Ottawa Hosp Res Inst, Rehabil Ctr, Ottawa, ON, Canada
[3] Univ Ottawa, Fac Med, Ottawa, ON, Canada
关键词
amputation; prosthesis; hip disarticulation; hemipelvectomy; rehabilitation; simulator; artificial limb; ENERGY-EXPENDITURE; DISARTICULATION; WALKING; GAIT;
D O I
10.1097/PXR.0000000000000208
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
People with a limb loss at the level of the hip or pelvis have the most difficulty returning to walking compared with those with a lower amputation. This is because their prosthesis must replace the hip, knee, and ankle joints. An adjustable hip-disarticulation/hemipelvectomy prosthesis simulator that allows able-bodied individuals to wear and assess a prosthesis can help researchers and manufacturers when designing new prosthetic components (ie, hip joints). SolidWorks computer-aided design software was used to design and simulate an adapter that can connect prosthetic components to an off-the-shelf hip abduction orthosis. The adapter was made of 1020 stainless steel and aluminium 6061-T3 with a yield strength of 276 MPa. To confirm that this adapter is strong and safe for ambulation, mechanical testing was performed using an INSTRON machine. The maximum loads generated in any activity were chosen according to the International Organization for Standardization 15032:2000 standard for hip disarticulation external prostheses. The designed adapter allowed frontal, lateral, or distal mounting of different prosthetic hip joints. Mechanical testing confirmed that the new adapter can withstand forces and moments experienced during ambulation. The hip disarticulation/hemipelvectomy prosthesis simulator is easy to use and adjustable based on each person's height and pelvic width. Furthermore, this simulator would assist rehabilitation practitioners in experiencing the use of hip-level prostheses and give them a better understanding of people using such technologies. The next step in this project is to evaluate able-bodied participant gait while using this hip simulator prosthesis with different hip joints.
引用
收藏
页码:443 / 446
页数:4
相关论文
共 50 条
  • [41] Postless Hip Arthroscopy: A Technical Note on Obtaining Distraction
    Leafblad, Nels
    Mizels, Josh
    Maak, Travis
    ARTHROSCOPY TECHNIQUES, 2024, 13 (01):
  • [42] STUDIES ON CAUSES OF LOOSENED HIP-PROSTHESIS AS BASIS FOR NEW PROSTHESIS DESIGN
    ENGELHARDT, A
    GRELL, H
    JUST, WD
    ZEITSCHRIFT FUR ORTHOPADIE UND IHRE GRENZGEBIETE, 1980, 118 (04): : 585 - 585
  • [43] Design and evaluation of vibratory shoe on balance control for elderly subjects: technical note
    Aboutorabi, Atefeh
    Arazpour, Mokhtar
    Farahmand, Farzam
    Bahramizadeh, Mahmood
    Fadayevatan, Reza
    Abdollahi, Ehsan
    DISABILITY AND REHABILITATION-ASSISTIVE TECHNOLOGY, 2018, 13 (02) : 173 - 177
  • [44] Design and Evaluation of a Sustained Release Gastroretentive Dosage Form of Captopril: A Technical Note
    Patel, P.
    Dand, N.
    Somwanshi, A.
    Kadam, V. J.
    Hirlekar, R. S.
    AAPS PHARMSCITECH, 2008, 9 (03) : 836 - 839
  • [45] Design and Evaluation of a Sustained Release Gastroretentive Dosage Form of Captopril: A Technical Note
    P. Patel
    N. Dand
    A. Somwanshi
    V. J. Kadam
    R. S. Hirlekar
    AAPS PharmSciTech, 2008, 9 : 836 - 839
  • [46] Iterative design and evaluation of new prone carts for individuals with SCDs:: A technical note
    Malassigné, P
    Nelson, AL
    Cors, MW
    Jensen, RP
    Amato, M
    Schnurr, E
    Amerson, TL
    JOURNAL OF REHABILITATION RESEARCH AND DEVELOPMENT, 2002, 39 (01): : 127 - 139
  • [47] Early Polyethylene Failure in a Modern Total Hip Prosthesis: A Note of Caution
    Thomas, W. Christian
    Parvataneni, Hari K.
    Vlasak, Richard G.
    Gray, Chancellor F.
    JOURNAL OF ARTHROPLASTY, 2020, 35 (05): : 1297 - 1302
  • [48] Wear of alumina-on-alumina total hip prosthesis: Effect of diametrical clearance and lubricant on hip simulator test
    Oonishi, H
    Clarke, IC
    Good, V
    Ueno, M
    Amino, H
    ARTHROPLASTY 2000: RECENT ADVANCES IN TOTAL JOINT REPLACEMENT, 2001, : 35 - 39
  • [49] Simplified Protocol for Relining Provisional Prosthesis on Natural Abutments: A Technical Note
    Galli, Fabio
    Deflorian, Matteo
    Testori, Tiziano
    INTERNATIONAL JOURNAL OF PERIODONTICS & RESTORATIVE DENTISTRY, 2018, 38 (02) : E25 - E28
  • [50] An above-knee prosthesis with a system of energy recovery: A technical note
    Farber, BS
    Jacobson, JS
    JOURNAL OF REHABILITATION RESEARCH AND DEVELOPMENT, 1995, 32 (04): : 337 - 348