Three-dimensional-printed patient-specific guides for tibial deformity correction in small-breed dogs

被引:0
|
作者
Jeon, Ji-Won [1 ,2 ]
Kang, Kyu-Won [1 ,2 ]
Kim, Woo-Keyoung [1 ,2 ,3 ]
Jung, Changsu [4 ]
Kang, Byung-Jae [1 ,2 ,3 ]
机构
[1] Seoul Natl Univ, Coll Vet Med, Dept Vet Clin Sci, Seoul, South Korea
[2] Seoul Natl Univ, Res Inst Vet Sci, Seoul, South Korea
[3] Seoul Natl Univ, BK21 FOUR Future Vet Med Leading Educ & Res Ctr BK, Seoul, South Korea
[4] Ilsan Anim Med Ctr, Gyeonggi Do, South Korea
基金
新加坡国家研究基金会;
关键词
tibial deformity; corrective osteotomy; 3-D-printed guide; closing wedge osteotomy; small-breed dog; PLATEAU LEVELING OSTEOTOMY; CRUCIATE LIGAMENT DISEASE; MEDIAL PATELLAR LUXATION; CLOSING WEDGE OSTEOTOMY; SURGICAL-CORRECTION; ANTEBRACHIAL DEFORMITY; COMPUTED-TOMOGRAPHY; PREMATURE CLOSURE; DEFICIENT STIFLES; RADIAL TORSION;
D O I
10.2460/ajvr.23.06.0146
中图分类号
S85 [动物医学(兽医学)];
学科分类号
0906 ;
摘要
OBJECTIVE To describe the use of patient-specific 3-D-printed osteotomy, reduction, and compression guides for tibial closing wedge osteotomy in small-breed dogs.ANIMALS6 dogs with unilateral tibial deformities.METHODSSix small-breed dogs with 1 or a combination of tibial deformities, including excessive tibial plateau angle, valgus, and torsion, were scheduled to undergo tibial closing wedge osteotomy using patient-specific 3-D-printed oste- otomy, reduction, and compression guides. The location and orientation of the wedge osteotomy were determined based on CT data using computer-aided design software. After the tibial deformities were corrected, postoperative CT or radiographs were obtained to compare the achieved tibial limb angles with the planned angles. Clinical evalu-ation and radiographic follow-up were performed on all dogs.RESULTSGuides were successfully positioned at each specific location, and osteotomies were performed without radiation exposure or observer assistance in all dogs. Tibial deformities were corrected with angular errors of 1.8 +/- 1.4 degrees, 2.3 +/- 2.1 degrees, and 2.6 +/- 1.3 degrees in the sagittal, frontal, and transverse planes, respectively. Mild complications resolved within 1 month in 3 dogs, and revision surgery was not required. Five dogs improved to the normal gait (mean, 14.8 +/- 6.6 weeks), and 1 dog recovered a satisfactory gait 24 weeks after surgery. All limbs healed 14 +/- 4.7 weeks after surgery.CLINICAL RELEVANCEPatient-specific 3-D-printed osteotomy, reduction, and compression guides can provide effective assistance allow- ing accurate correction of tibial deformities. Their use yields good clinical outcomes in small-breed dogs.
引用
收藏
页数:9
相关论文
共 50 条
  • [11] Can three-dimensional patient-specific cutting guides be used to achieve optimal correction for high tibial osteotomy? Pilot study
    Munier, M.
    Donnez, M.
    Ollivier, M.
    Flecher, X.
    Chabrand, P.
    Argenson, J. -N.
    Parratte, S.
    ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2017, 103 (02) : 245 - 250
  • [12] A novel patient-specific three-dimensional-printed external template to guide iliosacral screw insertion: a retrospective study
    Fan Yang
    Sheng Yao
    Kai-fang Chen
    Feng-zhao Zhu
    Ze-kang Xiong
    Yan-hui Ji
    Ting-fang Sun
    Xiao-dong Guo
    BMC Musculoskeletal Disorders, 19
  • [13] Three dimensional patient-specific printed cutting guides for closing-wedge distal femoral osteotomy
    JianHui Shi
    Wei Lv
    Yan Wang
    Ben Ma
    Wei Cui
    ZhenZhong Liu
    KeCheng Han
    International Orthopaedics, 2019, 43 : 619 - 624
  • [14] Three dimensional patient-specific printed cutting guides for closing-wedge distal femoral osteotomy
    Shi, JianHui
    Lv, Wei
    Wang, Yan
    Ma, Ben
    Cui, Wei
    Liu, ZhenZhong
    Han, KeCheng
    INTERNATIONAL ORTHOPAEDICS, 2019, 43 (03) : 619 - 624
  • [15] Three dimensional-printed patient-specific cutting guides for femoral varization osteotomy: Do it yourself
    Arnal-Burro, Juan
    Perez-Mananes, Ruben
    Gallo-del-Valle, Eudaldo
    Igualada-Blazquez, Cristina
    Cuervas-Mons, Manuel
    Vaquero-Martin, Javier
    KNEE, 2017, 24 (06): : 1359 - 1368
  • [16] A novel three-dimensional-printed patient-specific sacral implant for spinopelvic reconstruction in sacral giant cell tumour
    Lv, ZhaoRui
    Li, Jianmin
    Yang, ZhiPing
    Li, Xin
    Yang, Qiang
    Li, ZhenFeng
    INTERNATIONAL ORTHOPAEDICS, 2023, 47 (06) : 1619 - 1628
  • [17] Registration Accuracy of Patient-Specific, Three-Dimensional-Printed Prostate Molds for Correlating Pathology With Magnetic Resonance Imaging
    Priester, Alan
    Wu, Holden
    Khoshnoodi, Pooria
    Schneider, Douglas
    Zhang, Zhaohuan
    Asvadi, Nazanin H.
    Sisk, Anthony
    Raman, Steven
    Reiter, Robert
    Grundfest, Warren
    Marks, Leonard S.
    Natarajan, Shyam
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2019, 66 (01) : 14 - 22
  • [18] A novel three-dimensional-printed patient-specific sacral implant for spinopelvic reconstruction in sacral giant cell tumour
    ZhaoRui Lv
    Jianmin Li
    ZhiPing Yang
    Xin Li
    Qiang Yang
    ZhenFeng Li
    International Orthopaedics, 2023, 47 : 1619 - 1628
  • [19] Comparison of three-dimensional printed patient-specific guides versus freehand approach for radial osteotomies in normal dogs: Ex vivo model
    Townsend, Adam
    Guevar, Julien
    Oxley, Bill
    Hetzel, Scott
    Bleedorn, Jason
    VETERINARY SURGERY, 2024, 53 (02) : 234 - 242