Registration Accuracy of Patient-Specific, Three-Dimensional-Printed Prostate Molds for Correlating Pathology With Magnetic Resonance Imaging

被引:7
|
作者
Priester, Alan [1 ,2 ]
Wu, Holden [3 ]
Khoshnoodi, Pooria [3 ]
Schneider, Douglas [4 ]
Zhang, Zhaohuan [3 ]
Asvadi, Nazanin H. [3 ]
Sisk, Anthony [5 ]
Raman, Steven [3 ]
Reiter, Robert [2 ]
Grundfest, Warren [1 ]
Marks, Leonard S. [2 ]
Natarajan, Shyam [2 ]
机构
[1] Univ Calif Los Angeles, Dept Bioengn, Los Angeles, CA 90095 USA
[2] Univ Calif Los Angeles, David Geffen Sch Med, Dept Urol, Los Angeles, CA 90095 USA
[3] Univ Calif Los Angeles, David Geffen Sch Med, Dept Radiol Sci, Los Angeles, CA 90095 USA
[4] Univ Calif Los Angeles, Dept Ecol & Evolutionary Biol, Los Angeles, CA USA
[5] Univ Calif Los Angeles, David Geffen Sch Med, Dept Pathol, Los Angeles, CA 90095 USA
关键词
Image registration; magnetic resonance imaging; pathology; phantoms; three-dimensional printing; MULTIPARAMETRIC MRI; HISTOLOGY; CANCER; SPECIMENS; METHODOLOGY; VALIDATION; ULTRASOUND; IMAGES; VOLUME;
D O I
10.1109/TBME.2018.2828304
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Objective: This investigation was performed to evaluate the registration accuracy between magnetic resonance imaging (MRI) and pathology using three-dimensional (3-D) printed molds. Methods: Tissue-mimicking prostate phantoms were manufactured with embedded fiducials. The fiducials were used to measure and compare target registration error (TRE) between phantoms that were sliced by hand versus phantoms that were sliced within 3-D-printed molds. Subsequently, ten radical prostatectomy specimens were placed inside molds, scanned with MRI, and then sliced. The ex vivo scan was used to assess the true location of whole mount (WM) slides relative to in vivo MRI. The TRE between WM and in vivo MRI was measured using anatomic landmarks. Results: Manually sliced phantoms had a 4.1-mm mean TRE, whereas mold-sliced phantoms had a 1.9-mmmean TRE. Similarly, mold-assisted slicing reduced mean angular misalignment around the left-right (LR) anatomic axis from 10.7 degrees to 4.5 degrees. However, ex vivo MRI revealed that excised prostates were misaligned within molds, including a mean 14 degrees rotation about the LR axis. The mean in-plane TRE was 3.3 mm using molds alone and 2.2 mm after registration was corrected with ex vivo MRI. Conclusion: Patient-specific molds improved accuracy relative to manual slicing techniques in a phantom model. However, the registration accuracy of surgically resected specimens was limited by their imperfect fit within molds. This limitation can be overcome with the addition of ex vivo imaging. Significance: The accuracy of 3-D-printed molds was characterized, quantifying their utility for facilitating MRI-pathology registration.
引用
收藏
页码:14 / 22
页数:9
相关论文
共 50 条
  • [1] Accuracy assessment of surgical planning and three-dimensional-printed patient-specific guides for orthopaedic osteotomies
    Sys, Gwen
    Eykens, Hannelore
    Lenaerts, Gerlinde
    Shumelinsky, Felix
    Robbrecht, Cedric
    Poffyn, Bart
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2017, 231 (06) : 499 - 508
  • [2] A system for evaluating magnetic resonance imaging of prostate cancer using patient-specific 3D printed molds
    Priester, Alan
    Natarajan, Shyam
    Le, Jesse D.
    Garritano, James
    Radosavcev, Bryan
    Grundfest, Warren
    Margolis, Daniel J. A.
    Marks, Leonard S.
    Huang, Jiaoti
    AMERICAN JOURNAL OF CLINICAL AND EXPERIMENTAL UROLOGY, 2014, 2 (02): : 127 - 135
  • [3] Patient-Specific Three-Dimensional-Printed and Bolus Material-Based Localization Grids for Magnetic Resonance Imaging-Guided Interventional Procedures
    Chu, Vivien W. S.
    Wong, Wing Ki
    Lee, Louis
    JOURNAL OF MEDICAL DEVICES-TRANSACTIONS OF THE ASME, 2024, 18 (01):
  • [4] Improved Magnetic Resonance Imaging-Pathology Correlation With Imaging-Derived, 3D-Printed, Patient-Specific Whole-Mount Molds of the Prostate
    Costa, Daniel N.
    Chatzinoff, Yonatan
    Passoni, Niccolo M.
    Kapur, Payal
    Roehrborn, Claus G.
    Xi, Yin
    Rofsky, Neil M.
    Torrealba, Jose
    Francis, Franto
    Futch, Cecil
    Hagens, Phyllis
    Notgrass, Hollis
    Otero-Muinelo, Susana
    Pedrosa, Ivan
    Chopra, Rajiv
    INVESTIGATIVE RADIOLOGY, 2017, 52 (09) : 507 - 513
  • [5] Re: Magnetic Resonance Imaging Underestimation of Prostate Cancer Geometry: Use of Patient-specific Molds to Correlate Images with Whole-mount Pathology
    van der Kwast, Theo
    EUROPEAN UROLOGY, 2018, 73 (01) : 139 - 139
  • [6] Advances and Applications of Three-Dimensional-Printed Patient-Specific Chest Phantoms in Radiology: A Systematic Review
    Silberstein, Jenna
    Sun, Zhonghua
    APPLIED SCIENCES-BASEL, 2024, 14 (13):
  • [7] Accuracy of patient-specific three-dimensional-printed osteotomy and reduction guides for distal femoral osteotomy in dogs with medial patella luxation
    Hall, Emma L.
    Baines, Stephen
    Bilmont, Alexis
    Oxley, Bill
    VETERINARY SURGERY, 2019, 48 (04) : 584 - 591
  • [8] Three-dimensional-printed patient-specific guides for tibial deformity correction in small-breed dogs
    Jeon, Ji-Won
    Kang, Kyu-Won
    Kim, Woo-Keyoung
    Jung, Changsu
    Kang, Byung-Jae
    AMERICAN JOURNAL OF VETERINARY RESEARCH, 2023, 84 (12)
  • [9] A novel patient-specific three-dimensional-printed external template to guide iliosacral screw insertion: a retrospective study
    Yang, Fan
    Yao, Sheng
    Chen, Kai-fang
    Zhu, Feng-zhao
    Xiong, Ze-kang
    Ji, Yan-hui
    Sun, Ting-fang
    Guo, Xiao-dong
    BMC MUSCULOSKELETAL DISORDERS, 2018, 19
  • [10] A novel patient-specific three-dimensional-printed external template to guide iliosacral screw insertion: a retrospective study
    Fan Yang
    Sheng Yao
    Kai-fang Chen
    Feng-zhao Zhu
    Ze-kang Xiong
    Yan-hui Ji
    Ting-fang Sun
    Xiao-dong Guo
    BMC Musculoskeletal Disorders, 19