Accuracy assessment of surgical planning and three-dimensional-printed patient-specific guides for orthopaedic osteotomies

被引:18
|
作者
Sys, Gwen [1 ]
Eykens, Hannelore [2 ]
Lenaerts, Gerlinde [2 ]
Shumelinsky, Felix [3 ]
Robbrecht, Cedric [1 ]
Poffyn, Bart [1 ]
机构
[1] Ghent Univ Hosp, Dept Orthopaed Surg & Traumatol, De Pintelaan 185, B-9000 Ghent, Belgium
[2] Materialise NV, Leuven, Belgium
[3] Univ Libre Bruxelles, Inst Jules Bordet, Dept Orthopaed Surg, Brussels, Belgium
关键词
Patient-specific guides; three-dimensional printing; surgical planning; orthopaedic procedures; computer-assisted surgery; TOTAL KNEE ARTHROPLASTY; OF-THE-ART; MAXILLOFACIAL RECONSTRUCTION; CRANIOMAXILLOFACIAL SURGERY; CORRECTIVE OSTEOTOMY; COMPUTER-SIMULATION; WIDE RESECTION; DISTAL RADIUS; BONE-TUMORS; REPLACEMENT;
D O I
10.1177/0954411917702177
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
This study analyses the accuracy of three-dimensional pre-operative planning and patient-specific guides for orthopaedic osteotomies. To this end, patient-specific guides were compared to the classical freehand method in an experimental setup with saw bones in two phases. In the first phase, the effect of guide design and oscillating versus reciprocating saws was analysed. The difference between target and performed cuts was quantified by the average distance deviation and average angular deviations in the sagittal and coronal planes for the different osteotomies. The results indicated that for one model osteotomy, the use of guides resulted in a more accurate cut when compared to the freehand technique. Reciprocating saws and slot guides improved accuracy in all planes, while oscillating saws and open guides lead to larger deviations from the planned cut. In the second phase, the accuracy of transfer of the planning to the surgical field with slot guides and a reciprocating saw was assessed and compared to the classical planning and freehand cutting method. The pre-operative plan was transferred with high accuracy. Three-dimensional-printed patient-specific guides improve the accuracy of osteotomies and bony resections in an experimental setup compared to conventional freehand methods. The improved accuracy is related to (1) a detailed and qualitative pre-operative plan and (2) an accurate transfer of the planning to the operation room with patient-specific guides by an accurate guidance of the surgical tools to perform the desired cuts.
引用
收藏
页码:499 / 508
页数:10
相关论文
共 50 条
  • [1] Accuracy of patient-specific three-dimensional-printed osteotomy and reduction guides for distal femoral osteotomy in dogs with medial patella luxation
    Hall, Emma L.
    Baines, Stephen
    Bilmont, Alexis
    Oxley, Bill
    VETERINARY SURGERY, 2019, 48 (04) : 584 - 591
  • [2] Three-dimensional-printed patient-specific guides for tibial deformity correction in small-breed dogs
    Jeon, Ji-Won
    Kang, Kyu-Won
    Kim, Woo-Keyoung
    Jung, Changsu
    Kang, Byung-Jae
    AMERICAN JOURNAL OF VETERINARY RESEARCH, 2023, 84 (12)
  • [3] Three-Dimensional-Printed Patient-Specific Osteotomy Guides, Repositioning Guides and Titanium Plates for Acute Correction of Antebrachial Limb Deformities in Dogs
    Carwardine, Darren R.
    Gosling, Mark J.
    Burton, Neil J.
    O'Malley, Ffion L.
    Parsons, Kevin J.
    VETERINARY AND COMPARATIVE ORTHOPAEDICS AND TRAUMATOLOGY, 2021, 34 (01) : 43 - 52
  • [4] Registration Accuracy of Patient-Specific, Three-Dimensional-Printed Prostate Molds for Correlating Pathology With Magnetic Resonance Imaging
    Priester, Alan
    Wu, Holden
    Khoshnoodi, Pooria
    Schneider, Douglas
    Zhang, Zhaohuan
    Asvadi, Nazanin H.
    Sisk, Anthony
    Raman, Steven
    Reiter, Robert
    Grundfest, Warren
    Marks, Leonard S.
    Natarajan, Shyam
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2019, 66 (01) : 14 - 22
  • [5] Three-dimensional postoperative accuracy of extra-articular forearm osteotomies using CT-scan based patient-specific surgical guides
    Lazaros Vlachopoulos
    Andreas Schweizer
    Matthias Graf
    Ladislav Nagy
    Philipp Fürnstahl
    BMC Musculoskeletal Disorders, 16
  • [6] Three-dimensional postoperative accuracy of extra-articular forearm osteotomies using CT-scan based patient-specific surgical guides
    Vlachopoulos, Lazaros
    Schweizer, Andreas
    Graf, Matthias
    Nagy, Ladislav
    Fuernstahl, Philipp
    BMC MUSCULOSKELETAL DISORDERS, 2015, 16
  • [7] Accuracy of three-dimensional printed patient-specific drill guides for treatment of canine humeral intracondylar fissure
    Easter, Tim G.
    Bilmont, Alexis
    Pink, Jonathan
    Oxley, Bill
    VETERINARY SURGERY, 2020, 49 (02) : 363 - 372
  • [8] Advances and Applications of Three-Dimensional-Printed Patient-Specific Chest Phantoms in Radiology: A Systematic Review
    Silberstein, Jenna
    Sun, Zhonghua
    APPLIED SCIENCES-BASEL, 2024, 14 (13):
  • [9] Three-dimensional corrective osteotomies of complex malunited humeral fractures using patient-specific guides
    Vlachopoulos, Lazaros
    Schweizer, Andreas
    Meyer, Dominik C.
    Gerber, Christian
    Fuernstahl, Philipp
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2016, 25 (12) : 2040 - 2047
  • [10] Complex Osteotomies of Tibial Plateau Malunions Using Computer-Assisted Planning and Patient-Specific Surgical Guides
    Fuernstahl, Philipp
    Vlachopoulos, Lazaros
    Schweizer, Andreas
    Fucentese, Sandro F.
    Koch, Peter P.
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2015, 29 (08) : E270 - E276