Three-dimensional-printed patient-specific guides for tibial deformity correction in small-breed dogs

被引:0
|
作者
Jeon, Ji-Won [1 ,2 ]
Kang, Kyu-Won [1 ,2 ]
Kim, Woo-Keyoung [1 ,2 ,3 ]
Jung, Changsu [4 ]
Kang, Byung-Jae [1 ,2 ,3 ]
机构
[1] Seoul Natl Univ, Coll Vet Med, Dept Vet Clin Sci, Seoul, South Korea
[2] Seoul Natl Univ, Res Inst Vet Sci, Seoul, South Korea
[3] Seoul Natl Univ, BK21 FOUR Future Vet Med Leading Educ & Res Ctr BK, Seoul, South Korea
[4] Ilsan Anim Med Ctr, Gyeonggi Do, South Korea
基金
新加坡国家研究基金会;
关键词
tibial deformity; corrective osteotomy; 3-D-printed guide; closing wedge osteotomy; small-breed dog; PLATEAU LEVELING OSTEOTOMY; CRUCIATE LIGAMENT DISEASE; MEDIAL PATELLAR LUXATION; CLOSING WEDGE OSTEOTOMY; SURGICAL-CORRECTION; ANTEBRACHIAL DEFORMITY; COMPUTED-TOMOGRAPHY; PREMATURE CLOSURE; DEFICIENT STIFLES; RADIAL TORSION;
D O I
10.2460/ajvr.23.06.0146
中图分类号
S85 [动物医学(兽医学)];
学科分类号
0906 ;
摘要
OBJECTIVE To describe the use of patient-specific 3-D-printed osteotomy, reduction, and compression guides for tibial closing wedge osteotomy in small-breed dogs.ANIMALS6 dogs with unilateral tibial deformities.METHODSSix small-breed dogs with 1 or a combination of tibial deformities, including excessive tibial plateau angle, valgus, and torsion, were scheduled to undergo tibial closing wedge osteotomy using patient-specific 3-D-printed oste- otomy, reduction, and compression guides. The location and orientation of the wedge osteotomy were determined based on CT data using computer-aided design software. After the tibial deformities were corrected, postoperative CT or radiographs were obtained to compare the achieved tibial limb angles with the planned angles. Clinical evalu-ation and radiographic follow-up were performed on all dogs.RESULTSGuides were successfully positioned at each specific location, and osteotomies were performed without radiation exposure or observer assistance in all dogs. Tibial deformities were corrected with angular errors of 1.8 +/- 1.4 degrees, 2.3 +/- 2.1 degrees, and 2.6 +/- 1.3 degrees in the sagittal, frontal, and transverse planes, respectively. Mild complications resolved within 1 month in 3 dogs, and revision surgery was not required. Five dogs improved to the normal gait (mean, 14.8 +/- 6.6 weeks), and 1 dog recovered a satisfactory gait 24 weeks after surgery. All limbs healed 14 +/- 4.7 weeks after surgery.CLINICAL RELEVANCEPatient-specific 3-D-printed osteotomy, reduction, and compression guides can provide effective assistance allow- ing accurate correction of tibial deformities. Their use yields good clinical outcomes in small-breed dogs.
引用
收藏
页数:9
相关论文
共 50 条
  • [21] Three-Dimensional-Printed Patient-Specific Total Cuboid Replacement for Treatment of Post-traumatic Arthritis A Case Report
    Leatham, Paul R.
    Highlander, Peter D.
    JOURNAL OF THE AMERICAN PODIATRIC MEDICAL ASSOCIATION, 2024, 114 (03)
  • [22] Efficacy of virtual surgical planning and a three-dimensional-printed, patient-specific reduction system to facilitate alignment of diaphyseal tibial fractures stabilized by minimally invasive plate osteosynthesis in dogs: A prospective clinical study
    Scheuermann, Logan M.
    Lewis, Daniel D.
    Johnson, Matthew D.
    Biedrzycki, Adam H.
    Kim, Stanley E.
    VETERINARY SURGERY, 2024, 53 (06) : 1039 - 1051
  • [23] Bilateral shoulder arthrodesis in a Pekinese using three-dimensional printed patient-specific osteotomy and reduction guides
    Oxley, Bill
    VETERINARY AND COMPARATIVE ORTHOPAEDICS AND TRAUMATOLOGY, 2017, 30 (03) : 230 - 236
  • [24] Accuracy of three-dimensional printed patient-specific drill guides for treatment of canine humeral intracondylar fissure
    Easter, Tim G.
    Bilmont, Alexis
    Pink, Jonathan
    Oxley, Bill
    VETERINARY SURGERY, 2020, 49 (02) : 363 - 372
  • [25] Are three-dimensional patient-specific cutting guides for open wedge high tibial osteotomy accurate? An in vitro study
    Donnez, Mathias
    Ollivier, Matthieu
    Munier, Maxime
    Berton, Philippe
    Podgorski, Jean-Pierre
    Chabrand, Patrick
    Parratte, Sebastien
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2018, 13
  • [26] Are three-dimensional patient-specific cutting guides for open wedge high tibial osteotomy accurate? An in vitro study
    Mathias Donnez
    Matthieu Ollivier
    Maxime Munier
    Philippe Berton
    Jean-Pierre Podgorski
    Patrick Chabrand
    Sébastien Parratte
    Journal of Orthopaedic Surgery and Research, 13
  • [27] Slope and frontal axis: three-dimensional analysis and correction with patient-specific cutting guides for the proximal tibia
    Imhoff, Florian B.
    Vlachopoulos, Lazaros
    OPERATIVE ORTHOPADIE UND TRAUMATOLOGIE, 2023, 35 (05): : 248 - 257
  • [28] Computer-Assisted Planning and Three-Dimensional-Printed Patient-Specific Instrumental Guide for Corrective Osteotomy in Post-Traumatic Femur Deformity: A Case Report and Literature Review
    Lau Chi-Kay
    Chui King-him
    Lee Kin-bong
    Li Wilson
    JOURNAL OF ORTHOPAEDICS TRAUMA AND REHABILITATION, 2018, 24 : 12 - 17
  • [29] Three-dimensional-printed patient-specific Kirschner-wire guide for percutaneous fixation of undisplaced scaphoid fractures: a cadaveric study
    Salabi, Vincent
    Rigoulot, Guillaume
    Sautet, Alain
    Cambon-Binder, Adeline
    JOURNAL OF HAND SURGERY-EUROPEAN VOLUME, 2019, 44 (07) : 692 - 696
  • [30] Three-dimensional accuracy of high tibial osteotomy using two generations of CT-based patient-specific guides
    Meier, Patrick
    Aichmair, Alexander
    Kochli, Gian Luca
    Vlachopoulos, Lazaros
    Furnstahl, Philipp
    Fucentese, Sandro F.
    SWISS MEDICAL WEEKLY, 2017, 147 : 57S - 57S