A Modified Formula for Intraocular Lens Power Calculation Based on Aphakic Refraction in a Pediatric Population

被引:1
|
作者
Jafarinasab, Mohammad-Reza [1 ]
Khosravi, Behrooz [2 ]
Esfandiari, Hamed [2 ]
Hooshmandi, Sadid [2 ]
Hassanpour, Kiana [2 ,3 ]
机构
[1] Shahid Beheshti Univ Med Sci, Res Inst Ophthalmol & Vis Sci, Ophthalm Epidemiol Res Ctr, Tehran, Iran
[2] Shahid Beheshti Univ Med Sci, Res Inst Ophthalmol & Vis Sci, Ophthalm Res Ctr, Tehran, Iran
[3] Shahid Beheshti Univ Med Sci, Res Inst Ophthalmol & Vis Sci, Ophthalm Res Ctr, Paidarfard St,Boostan 9th St,Pasdaran Ave, Tehran, Iran
关键词
Aphakic Refraction; Intraocular Lens (IOL); IOL Power Calculation; Pediatric Cataract; BIOMETRY;
D O I
10.18502/jovr.v18i1.12723
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To investigate and optimize the accuracy of aphakic refraction (AR) techniques for Methods: Thirty-three aphakic eyes of 18 patients who were candidates for secondary IOL implantation were enrolled in the present study. Axial length (AL) measured by optical biometry was used in the biometric formula (SRK-T, Holladay II, and Hoffer-Q). AR and spherical equivalent (SE) were used in two AR-based formulas (Ianchulev, Leccissotti). True power was calculated based on postoperative SE at three months' follow-up. Results: Regarding the postoperative SE, 13 (40%) eyes were within +/- 1.00 diopters (D) and 22 (66%) were within +/- 2.00 D. Median absolute error (MedAE) was predicted to be 4.4 and 7.3 D with the use of Ianchulev and Leccissotti formulas, respectively. The corresponding value was 0.8 D with the biometric formula. All eyes were deemed to have myopic refraction when using the AR-based formulas except one eye with the Ianchulev formula. The coefficient of our modified formula was 1.7 instead of 2.01 in the Ianchulev formula. MedAE with the use of new formulae was 0.5 D and was comparable with the true IOL power (P = 0.22). Conclusion: Both Ianchulev and Leccissotti formulas resulted in a significant myopic surprise in aphakic children aged between 4.5 and 14 years. The modified formula proved to determine a more accurate SE that is comparable with biometric formulas.
引用
收藏
页码:34 / 40
页数:7
相关论文
共 50 条
  • [31] Current accuracy of a simple Gaussian optics-based thin lens intraocular lens power calculation formula
    Klijn, Stijn
    Sicam, Victor Arni
    Reus, Nic J.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2014, 55 (13)
  • [32] Intraocular lens power calculation
    Olsen, Thomas
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2009, 35 (12): : 2176 - 2177
  • [33] Effect of optional biometric parameters in the Kane formula on intraocular lens power calculation
    Li, Xiao-Yu
    Liao, Xuan
    Lin, Jia
    Lan, Chang-Jun
    Tan, Qing-Qing
    PLOS ONE, 2023, 18 (08):
  • [34] FACTORS INFLUENCING THE ACCURACY OF THE SRK FORMULA IN THE INTRAOCULAR-LENS POWER CALCULATION
    KALOGEROPOULOS, C
    ASPIOTIS, M
    STEFANIOTOU, M
    PSILAS, K
    DOCUMENTA OPHTHALMOLOGICA, 1994, 85 (03) : 223 - 242
  • [35] A new formula for intraocular lens power calculation after refractive corneal surgery
    Camellin, M
    Calossi, A
    JOURNAL OF REFRACTIVE SURGERY, 2006, 22 (02) : 187 - 199
  • [36] Performance of a simplified strategy for formula constant optimisation in intraocular lens power calculation
    Langenbucher, Achim
    Wendelstein, Jascha
    Szentmary, Nora
    Cayless, Alan
    Hoffmann, Peter
    Debellmaniere, Guillaume
    Gatinel, Damien
    ACTA OPHTHALMOLOGICA, 2025, 103 (01) : e10 - e18
  • [37] DEVELOPMENT OF THE SRK/T INTRAOCULAR-LENS IMPLANT POWER CALCULATION FORMULA
    RETZLAFF, JA
    SANDERS, DR
    KRAFF, MC
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1990, 16 (03): : 333 - 340
  • [38] Intraocular lens power calculation following LASIK: Determination of the new effective index of refraction
    Jarade, EF
    Nader, FCA
    Tabbara, KF
    JOURNAL OF REFRACTIVE SURGERY, 2006, 22 (01) : 75 - 80
  • [39] THE SELECTION OF INTRAOCULAR-LENS POWER BY CALCULATION AND BY REFERENCE TO THE REFRACTION - A CLINICAL-STUDY
    HILLMAN, JS
    TRANSACTIONS OF THE OPHTHALMOLOGICAL SOCIETIES OF THE UNITED KINGDOM, 1982, 102 : 495 - 497
  • [40] Using continuous intraoperative optical coherence tomography measurements of the aphakic eye for intraocular lens power calculation
    Hirnschall, Nino
    Norrby, Sverker
    Weber, Maria
    Maedel, Sophie
    Amir-Asgari, Sahand
    Findl, Oliver
    BRITISH JOURNAL OF OPHTHALMOLOGY, 2015, 99 (01) : 7 - 10