A Modified Formula for Intraocular Lens Power Calculation Based on Aphakic Refraction in a Pediatric Population

被引:1
|
作者
Jafarinasab, Mohammad-Reza [1 ]
Khosravi, Behrooz [2 ]
Esfandiari, Hamed [2 ]
Hooshmandi, Sadid [2 ]
Hassanpour, Kiana [2 ,3 ]
机构
[1] Shahid Beheshti Univ Med Sci, Res Inst Ophthalmol & Vis Sci, Ophthalm Epidemiol Res Ctr, Tehran, Iran
[2] Shahid Beheshti Univ Med Sci, Res Inst Ophthalmol & Vis Sci, Ophthalm Res Ctr, Tehran, Iran
[3] Shahid Beheshti Univ Med Sci, Res Inst Ophthalmol & Vis Sci, Ophthalm Res Ctr, Paidarfard St,Boostan 9th St,Pasdaran Ave, Tehran, Iran
关键词
Aphakic Refraction; Intraocular Lens (IOL); IOL Power Calculation; Pediatric Cataract; BIOMETRY;
D O I
10.18502/jovr.v18i1.12723
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To investigate and optimize the accuracy of aphakic refraction (AR) techniques for Methods: Thirty-three aphakic eyes of 18 patients who were candidates for secondary IOL implantation were enrolled in the present study. Axial length (AL) measured by optical biometry was used in the biometric formula (SRK-T, Holladay II, and Hoffer-Q). AR and spherical equivalent (SE) were used in two AR-based formulas (Ianchulev, Leccissotti). True power was calculated based on postoperative SE at three months' follow-up. Results: Regarding the postoperative SE, 13 (40%) eyes were within +/- 1.00 diopters (D) and 22 (66%) were within +/- 2.00 D. Median absolute error (MedAE) was predicted to be 4.4 and 7.3 D with the use of Ianchulev and Leccissotti formulas, respectively. The corresponding value was 0.8 D with the biometric formula. All eyes were deemed to have myopic refraction when using the AR-based formulas except one eye with the Ianchulev formula. The coefficient of our modified formula was 1.7 instead of 2.01 in the Ianchulev formula. MedAE with the use of new formulae was 0.5 D and was comparable with the true IOL power (P = 0.22). Conclusion: Both Ianchulev and Leccissotti formulas resulted in a significant myopic surprise in aphakic children aged between 4.5 and 14 years. The modified formula proved to determine a more accurate SE that is comparable with biometric formulas.
引用
收藏
页码:34 / 40
页数:7
相关论文
共 50 条
  • [21] An Intraocular Lens Power Calculation Formula Based on Optical Coherence Tomography: A Pilot Study
    Tang, Maolong
    Li, Yan
    Huang, David
    JOURNAL OF REFRACTIVE SURGERY, 2010, 26 (06) : 430 - 437
  • [22] REGRESSION FORMULA VS RETINOSCOPY CALCULATION OF APHAKIC CONTACT-LENS POWER IN CHILDREN
    PHILIPH, DA
    SUMMERS, CG
    DAVIS, LK
    EGBERT, JE
    LETSON, RD
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1995, 36 (04) : S312 - S312
  • [23] Accuracy of the Holladay 2 intraocular lens formula for pediatric eyes in the absence of preoperative refraction
    Trivedi, Rupal H.
    Wilson, M. Edward
    Reardon, Wade
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2011, 37 (07): : 1239 - 1243
  • [24] Intraocular lens power calculation formula accuracy: Comparison of 12 formulas for a trifocal hydrophilic intraocular lens
    Rocha-de-Lossada, Carlos
    Colmenero-Reina, Elvira
    Flikier, David
    Castro-Alonso, Francisco-Javier
    Rodriguez-Raton, Alvaro
    Garcia-Madrona, Jose-Luis
    Peraza-Nieves, Jorge
    Sanchez-Gonzalez, Jose-Maria
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2021, 31 (06) : 2981 - 2988
  • [25] SRK-II FORMULA IN THE CALCULATION OF INTRAOCULAR-LENS POWER
    DANG, MS
    RAJ, PPS
    BRITISH JOURNAL OF OPHTHALMOLOGY, 1989, 73 (10) : 823 - 826
  • [26] Preliminary demonstration of a novel intraocular lens power calculation: the O formula
    Goto, So
    Maeda, Naoyuki
    Ohnuma, Kazuhiko
    Lawu, Tjundewo
    Kawasaki, Ryo
    Koh, Shizuka
    Nishida, Kohji
    Noda, Toru
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2022, 48 (11): : 1305 - 1311
  • [27] Comments on: Evaluation of Barrett universal II formula for intraocular lens power calculation in Asian Indian population
    Shrivastava, Ankur K.
    Nayak, Swatishree
    INDIAN JOURNAL OF OPHTHALMOLOGY, 2020, 68 (07) : 1507 - 1507
  • [28] THE TRIPLE PROCEDURE - ANALYSIS OF OUTCOME, REFRACTION, AND INTRAOCULAR-LENS POWER CALCULATION
    CRAWFORD, GJ
    STULTING, RD
    WARING, GO
    VANMETER, WS
    WILSON, LA
    OPHTHALMOLOGY, 1986, 93 (06) : 817 - 824
  • [29] Comparison of Intraocular Lens Power Calculation Formulae in Pediatric Eyes
    Nihalani, Bharti R.
    VanderVeen, Deborah K.
    OPHTHALMOLOGY, 2010, 117 (08) : 1493 - 1499
  • [30] Accuracy of Intraocular lens power calculation in pediatric traumatic cataract
    Goyal, Priya
    Tibrewal, Shailja
    Ganesh, Suma
    Rath, Soveeta
    Majumdar, Atanu
    INDIAN JOURNAL OF OPHTHALMOLOGY, 2024, 72 (11) : 1605 - 1610