A Modified Formula for Intraocular Lens Power Calculation Based on Aphakic Refraction in a Pediatric Population

被引:1
|
作者
Jafarinasab, Mohammad-Reza [1 ]
Khosravi, Behrooz [2 ]
Esfandiari, Hamed [2 ]
Hooshmandi, Sadid [2 ]
Hassanpour, Kiana [2 ,3 ]
机构
[1] Shahid Beheshti Univ Med Sci, Res Inst Ophthalmol & Vis Sci, Ophthalm Epidemiol Res Ctr, Tehran, Iran
[2] Shahid Beheshti Univ Med Sci, Res Inst Ophthalmol & Vis Sci, Ophthalm Res Ctr, Tehran, Iran
[3] Shahid Beheshti Univ Med Sci, Res Inst Ophthalmol & Vis Sci, Ophthalm Res Ctr, Paidarfard St,Boostan 9th St,Pasdaran Ave, Tehran, Iran
关键词
Aphakic Refraction; Intraocular Lens (IOL); IOL Power Calculation; Pediatric Cataract; BIOMETRY;
D O I
10.18502/jovr.v18i1.12723
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To investigate and optimize the accuracy of aphakic refraction (AR) techniques for Methods: Thirty-three aphakic eyes of 18 patients who were candidates for secondary IOL implantation were enrolled in the present study. Axial length (AL) measured by optical biometry was used in the biometric formula (SRK-T, Holladay II, and Hoffer-Q). AR and spherical equivalent (SE) were used in two AR-based formulas (Ianchulev, Leccissotti). True power was calculated based on postoperative SE at three months' follow-up. Results: Regarding the postoperative SE, 13 (40%) eyes were within +/- 1.00 diopters (D) and 22 (66%) were within +/- 2.00 D. Median absolute error (MedAE) was predicted to be 4.4 and 7.3 D with the use of Ianchulev and Leccissotti formulas, respectively. The corresponding value was 0.8 D with the biometric formula. All eyes were deemed to have myopic refraction when using the AR-based formulas except one eye with the Ianchulev formula. The coefficient of our modified formula was 1.7 instead of 2.01 in the Ianchulev formula. MedAE with the use of new formulae was 0.5 D and was comparable with the true IOL power (P = 0.22). Conclusion: Both Ianchulev and Leccissotti formulas resulted in a significant myopic surprise in aphakic children aged between 4.5 and 14 years. The modified formula proved to determine a more accurate SE that is comparable with biometric formulas.
引用
收藏
页码:34 / 40
页数:7
相关论文
共 50 条
  • [41] Intraocular lens power calculation in pediatric cataract surgery: A narrative review
    Wojcik-Niklewska, Bogumila
    Nocon-Bratek, Martyna
    Szala, Klaudia
    MEDICINE, 2025, 104 (14)
  • [42] Intraocular lens power calculation for lens exchange
    Kora, Y
    Shimizu, K
    Yoshida, M
    Inatomi, M
    Ozawa, T
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2001, 27 (04): : 543 - 548
  • [43] The Zhu-Lu formula: a machine learning-based intraocular lens power calculation formula for highly myopic eyes
    Dongling Guo
    Wenwen He
    Ling Wei
    Yunxiao Song
    Jiao Qi
    Yunqian Yao
    Xu Chen
    Jinhai Huang
    Yi Lu
    Xiangjia Zhu
    Eye and Vision, 10
  • [44] The Zhu-Lu formula: a machine learning-based intraocular lens power calculation formula for highly myopic eyes
    Guo, Dongling
    He, Wenwen
    Wei, Ling
    Song, Yunxiao
    Qi, Jiao
    Yao, Yunqian
    Chen, Xu
    Huang, Jinhai
    Lu, Yi
    Zhu, Xiangjia
    EYE AND VISION, 2023, 10 (01)
  • [45] Comparison of Aphakic Refraction and Biometry-Based Formulae for Secondary In-The-Bag and Sulcus-Implanted Intraocular Lens Power Estimation in Children
    Chang, Pingjun
    Li, Zhangliang
    Zhang, Fan
    Lin, Lei
    Kou, Jiaojiao
    Zhao, Yun-e
    OPHTHALMIC RESEARCH, 2021, 64 (06) : 1048 - 1054
  • [46] Response to comments on: Evaluation of Barrett's universal II formula for intraocular lens power calculation in Asian Indian population
    Vanathi, Murugesan
    Kuthirummal, Nikhil
    Mukhija, Ritika
    Tandon, Radhika
    INDIAN JOURNAL OF OPHTHALMOLOGY, 2020, 68 (07) : 1508 - +
  • [47] INTRAOCULAR-LENS POWER CALCULATION
    HOPEROSS, M
    MOONEY, D
    EYE, 1988, 2 : 367 - 369
  • [48] CALCULATION OF INTRAOCULAR-LENS POWER
    SUNDERRAJ, P
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1990, 16 (03): : 387 - 388
  • [49] Intraocular lens power calculation in children
    Eibschitz-Tsimhoni, Maya
    Archer, Steven M.
    Del Monte, Monte A.
    SURVEY OF OPHTHALMOLOGY, 2007, 52 (05) : 474 - 482
  • [50] Intraocular lens power calculation software
    Kuchenbecker, J
    Behrens-Baumann, W
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2002, 28 (05): : 735 - 736