Effect of optional biometric parameters in the Kane formula on intraocular lens power calculation

被引:1
|
作者
Li, Xiao-Yu [1 ,2 ]
Liao, Xuan [1 ]
Lin, Jia [1 ]
Lan, Chang-Jun [3 ]
Tan, Qing-Qing [1 ]
机构
[1] North Sichuan Med Coll, Dept Ophthalmol, Affiliated Hosp, Nanchong, Peoples R China
[2] Nanchong Cent Hosp, Clin Coll 2, Dept Ophthalmol, North Sichuan Med Coll, Nanchong, Peoples R China
[3] Sichuan Eye Hosp, Chengdu, Peoples R China
来源
PLOS ONE | 2023年 / 18卷 / 08期
关键词
PURSUING PERFECTION; ACCURACY;
D O I
10.1371/journal.pone.0289033
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
PurposeTo investigate the effect of the optional biometric parameters lens thickness (LT) and center corneal thickness (CCT) in the Kane formula on intraocular lens (IOL) power calculation.MethodsA cross-sectional study included consecutive cataract patients who received uncomplicated cataract surgery with IOL implantation from May to September 2022 were enrolled. The ocular biometric parameters were obtained using IOLMaster 700 and then inputted into online Kane formula calculator. The IOL power was calculated for targeting emmetropia and compared between groups: not omitting (NO) group, omitting LT and CCT (OLC) group, omitting LT (OL) group and omitting CCT (OC) group. Further, according to the axial length (AL), anterior chamber depth (ACD), and mean keratometry (K-m), the eyes were divided into three subgroups, respectively.Results1005 eyes of 1005 consecutive patients were included. There was no significant difference in IOL power between NO group and OC group (P = 0.064), and the median absolute difference (MedAD) was 0.05D. The IOL power in NO group showed significant differences from OLC group and OL group respectively (P < 0.001), and both MedAD values were 0.18D. Among AL subgroups, MedAD ranged from 0.06D to 0.35D in short eyes. Among ACD subgroups, the above values ranged from 0.06D to 0.23D in shallow ACD subgroup. Among K-m subgroups, these values ranged from 0.05D to 0.31D in steep K-m subgroup.ConclusionThe optional biometric parameter CCT has no effect on the calculation results of the Kane formula, whereas the parameter LT has a great influence on the Kane formula results for the IOL power calculation in cataract patients with short AL, shallow ACD and steep K-m.
引用
收藏
页数:11
相关论文
共 50 条
  • [1] Accuracy of the Kane Formula for Intraocular Lens Power Calculation in Comparison with Existing Formulas: A Retrospective Review
    Ryu, Soyoung
    Jun, Ikhyun
    Kim, Tae-im
    Kim, Eung Kweon
    Seo, Kyoung Yul
    YONSEI MEDICAL JOURNAL, 2021, 62 (12) : 1117 - 1124
  • [2] Intraocular lens power calculation in the elderly population using the Kane formula in comparison with existing methods
    Reitblat, Olga
    Gali, Helena E.
    Chou, Linda
    Bahar, Irit
    Weinreb, Robert N.
    Afshari, Natalie A.
    Sella, Ruti
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2020, 46 (11): : 1501 - 1507
  • [3] Influence of Pilocarpine Eyedrops on the Ocular Biometric Parameters and Intraocular Lens Power Calculation
    Gao, Ruxin
    Liu, Jinkun
    Zhou, Xiaojie
    Huang, Luping
    Huang, Weiyi
    Xue, Yingying
    Wang, Fei
    Gong, Songjian
    Wu, Renyi
    Wang, Yuhong
    JOURNAL OF OPHTHALMOLOGY, 2023, 2023
  • [4] The SRKII formula in the calculation of intraocular lens power
    Nurözler, A
    Ünlü, N
    Yalvaç, IS
    Kasim, R
    Duman, S
    OPHTHALMOLOGICA, 1998, 212 (03) : 153 - 156
  • [5] The effect of pterygium surgery on intraocular lens power and ocular biometric parameters
    Dogan, Emine
    Cakir, Burcin
    Aksoy, Nilgun Ozkan
    Alagoz, Gursoy
    IRISH JOURNAL OF MEDICAL SCIENCE, 2022, 191 (05) : 2399 - 2403
  • [6] Does blepharospasm effect biometric parameters and intraocular lens power calculations?
    Basol, Ibrahim
    Ilhan, Hatice Deniz
    INTERNATIONAL OPHTHALMOLOGY, 2024, 44 (01)
  • [7] The effect of pterygium surgery on intraocular lens power and ocular biometric parameters
    Emine Dogan
    Burcin Cakir
    Nilgun Ozkan Aksoy
    Gürsoy Alagöz
    Irish Journal of Medical Science (1971 -), 2022, 191 : 2399 - 2403
  • [8] Comparison of the Kane formula with existing formulas for intraocular lens power selection
    Connell, Benjamin J.
    Kane, Jack X.
    BMJ OPEN OPHTHALMOLOGY, 2019, 4 (01):
  • [9] Considerations of a thick lens formula for intraocular lens power calculation
    Langenbucher, Achim
    Hoffmann, Peter
    Cayless, Alan
    Gatinel, Damien
    Debellemaniere, Guillaume
    Wendelstein, Jascha
    Szentmary, Nora
    ZEITSCHRIFT FUR MEDIZINISCHE PHYSIK, 2024, 34 (04): : 620 - 631
  • [10] INTRAOCULAR-LENS POWER CALCULATION - THE SELECTION OF FORMULA
    HILLMAN, JS
    TRANSACTIONS OF THE OPHTHALMOLOGICAL SOCIETIES OF THE UNITED KINGDOM, 1985, 104 : 693 - 698