Intra- and inter-rater reliability in ultrasonographic measurements of coracohumeral distance

被引:0
|
作者
Guerra-Rodriguez, Diego [1 ]
Guerrero-Henriquez, Juan [2 ,3 ,7 ]
Basilio, Daniel [4 ]
Mendez-Rebolledo, Guillermo [5 ,6 ]
机构
[1] Univ Antofagasta, Fac Hlth Sci, Biomed Dept, Antofagasta, Chile
[2] Univ Antofagasta, Fac Hlth Sci, Rehabil & Human Movement Sci Dept, Antofagasta, Chile
[3] Univ Antofagasta, Fac Ciencias Salud, Ctr Invest Fisiol & Med Altura, Antofagasta, Chile
[4] Kinet K Integral Therapy & Training Ctr, Antofagasta, Chile
[5] Univ Santo Tomas, Escuela Kinesiol, Fac Salud, Lab Invest Somatosensorial & Motora, Santiago, Chile
[6] Univ Santo Tomas, Escuela Kinesiol, Fac Salud, Santiago, Chile
[7] Univ Antofagasta, Avda Univ Antofagasta 02800, Antofagasta 1240000, Chile
关键词
Ultrasonography; Reliability; Shoulder; Subacromial space;
D O I
10.1016/j.msksp.2024.102906
中图分类号
R49 [康复医学];
学科分类号
100215 ;
摘要
Background: Ultrasonography (US) is a widely used diagnostic tool in physical therapy. One of the US variables often utilized to quantify the dimensions of the subacromial space and its association with shoulder pathology is the coracohumeral distance (CHD), however, this measurement presents diverse evidence in terms of reliability. Objectives: To assess the intra- and inter-rater reliability of both expert and non-expert raters when measuring CHD through US in asymptomatic subjects. Additionally, we determined the effect of rater experience and measurement conditions on the recording of CHD. Methods: CHD of 15 individuals were recorded from US images of the glenohumeral joint of both upper extremities in three different positions. An expert and a non-expert rater in US usage recorded three CHD measurements, after a randomization procedure. To determine intra- and inter-rater reliability, the interclass correlation coefficient (ICC) and a multivariate variance model for the effects of rater experience, joint position and time of measure were used. Standard Error of Measurement and Minimal Detectable Change was also estimated for CHD measurements. Results: Intra-rater reliability ranged 0.970 to 0.998) and Inter-rater reliability ranged 0.48 to 0.876). Joint position (F2;55 = 38.308; p < 0.001; eta 2p = 0.582) and measurement time (F2;55 = 6.019; p = 0.004; eta 2p = 0.180) effect was observed on CHD. Conclusion: Excellent intra- and poor to moderate inter-rater reliability between expert and non-expert clinicians was determined, the latter being influenced by the position of the glenohumeral joint position at the time of US recording and the time of recording the measurement.
引用
收藏
页数:5
相关论文
共 50 条
  • [21] Intra- And Inter-rater Reliability Of Sonographic Cross-sectional Area Measurements In Asymptomatic Patella Tendons
    Reschke, Antje
    Cassel, Michael
    Intziegianni, Konstantina
    Mayer, Frank
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2014, 46 (05): : 927 - 928
  • [22] Inter-Rater and Intra-Rater Reliability of Sonographic Median Nerve and Wrist Measurements
    Gonzalez-Suarez, Consuelo B.
    Buenavente, Ma Lorraine D.
    Cua, Ronald Christopher A.
    Fidel, Maria Belinda C.
    Cabrera, Jan-Tyrone C.
    Regala, Carina Fatima G.
    JOURNAL OF MEDICAL ULTRASOUND, 2018, 26 (01) : 14 - 23
  • [23] Intra-rater and inter-rater reliability of 3D facial measurements
    Hobbs-Murphy, Kayna
    Olmedo-Nockideneh, Isabel
    Brazile, William J.
    Morris, Kristen
    Rosecrance, John
    APPLIED ERGONOMICS, 2024, 116
  • [24] Intra and inter-rater reliability of skin fold measurements in university men
    de Oliveira Filho, Aluizio Picanco
    de Brito, Alex Lima
    Viana, Albert da Silva
    de Sousa de Lima Deniur, Jose Rodrigo
    de Azevedo Albuquerque, Ana Paula
    Pureza, Demilto Yamaguchida
    Materko, Wollner
    RBNE-REVISTA BRASILEIRA DE NUTRICAO ESPORTIVA, 2018, 12 (76): : 1079 - 1085
  • [25] Tele-Assessment of Functional Capacity: Validity, Intra- and Inter-rater Reliability
    Asliyüce, Yasemin Ozel
    Fanuscu, Aybuke
    Asliyüce, Abdurahim
    Ülger, Ozlem
    WORKPLACE HEALTH & SAFETY, 2023, 71 (10) : 476 - 483
  • [26] Pain pressure threshold algometry in knee osteoarthritis: intra- and inter-rater reliability
    Stausholm, Martin Bjorn
    Bjordal, Jan Magnus
    Moe-Nilssen, Rolf
    Naterstad, Ingvill Fjell
    PHYSIOTHERAPY THEORY AND PRACTICE, 2023, 39 (03) : 615 - 622
  • [27] Intra- and inter-rater reliability of the Bath ankylosing spondylitis metrology index (BASMI)
    Rintek Madsen, O.
    Hansen, L.
    Rytter, A.
    Suetta, C.
    Egsmose, C.
    SCANDINAVIAN JOURNAL OF RHEUMATOLOGY, 2006, 35 : 24 - 24
  • [28] Intra- and inter-rater reliability of digital image analysis for skin color measurement
    Sommers, Marilyn
    Beacham, Barbara
    Baker, Rachel
    Fargo, Jamison
    SKIN RESEARCH AND TECHNOLOGY, 2013, 19 (04) : 484 - 491
  • [29] The Intra- and Inter-Rater Reliability of an Instrumented Spasticity Assessment in Children with Cerebral Palsy
    Schless, Simon-Henri
    Desloovere, Kaat
    Aertbelien, Erwin
    Molenaers, Guy
    Huenaerts, Catherine
    Bar-On, Lynn
    PLOS ONE, 2015, 10 (07):
  • [30] Intra- and inter-rater reliability of the manual method of measuring respiratory muscle coordination
    Rodrigues, Antenor
    Xiong, Yijun
    Telias, Irene
    Goligher, Ewan
    Brochard, Laurent
    Reid, W. Darlene
    EUROPEAN RESPIRATORY JOURNAL, 2020, 56