Intra- and inter-rater reliability in ultrasonographic measurements of coracohumeral distance

被引:0
|
作者
Guerra-Rodriguez, Diego [1 ]
Guerrero-Henriquez, Juan [2 ,3 ,7 ]
Basilio, Daniel [4 ]
Mendez-Rebolledo, Guillermo [5 ,6 ]
机构
[1] Univ Antofagasta, Fac Hlth Sci, Biomed Dept, Antofagasta, Chile
[2] Univ Antofagasta, Fac Hlth Sci, Rehabil & Human Movement Sci Dept, Antofagasta, Chile
[3] Univ Antofagasta, Fac Ciencias Salud, Ctr Invest Fisiol & Med Altura, Antofagasta, Chile
[4] Kinet K Integral Therapy & Training Ctr, Antofagasta, Chile
[5] Univ Santo Tomas, Escuela Kinesiol, Fac Salud, Lab Invest Somatosensorial & Motora, Santiago, Chile
[6] Univ Santo Tomas, Escuela Kinesiol, Fac Salud, Santiago, Chile
[7] Univ Antofagasta, Avda Univ Antofagasta 02800, Antofagasta 1240000, Chile
关键词
Ultrasonography; Reliability; Shoulder; Subacromial space;
D O I
10.1016/j.msksp.2024.102906
中图分类号
R49 [康复医学];
学科分类号
100215 ;
摘要
Background: Ultrasonography (US) is a widely used diagnostic tool in physical therapy. One of the US variables often utilized to quantify the dimensions of the subacromial space and its association with shoulder pathology is the coracohumeral distance (CHD), however, this measurement presents diverse evidence in terms of reliability. Objectives: To assess the intra- and inter-rater reliability of both expert and non-expert raters when measuring CHD through US in asymptomatic subjects. Additionally, we determined the effect of rater experience and measurement conditions on the recording of CHD. Methods: CHD of 15 individuals were recorded from US images of the glenohumeral joint of both upper extremities in three different positions. An expert and a non-expert rater in US usage recorded three CHD measurements, after a randomization procedure. To determine intra- and inter-rater reliability, the interclass correlation coefficient (ICC) and a multivariate variance model for the effects of rater experience, joint position and time of measure were used. Standard Error of Measurement and Minimal Detectable Change was also estimated for CHD measurements. Results: Intra-rater reliability ranged 0.970 to 0.998) and Inter-rater reliability ranged 0.48 to 0.876). Joint position (F2;55 = 38.308; p < 0.001; eta 2p = 0.582) and measurement time (F2;55 = 6.019; p = 0.004; eta 2p = 0.180) effect was observed on CHD. Conclusion: Excellent intra- and poor to moderate inter-rater reliability between expert and non-expert clinicians was determined, the latter being influenced by the position of the glenohumeral joint position at the time of US recording and the time of recording the measurement.
引用
收藏
页数:5
相关论文
共 50 条
  • [31] Intra- and Inter-Rater Reliability of Ultrasound Measurements of Supraspinatus Tendon Thickness, Acrnmiohumeral Distance, and Occupatiun Ratio in Patients With Shoulder Impingement Syndrome
    Bagcier, Fatih
    Kulcu, Duygu Geler
    Yorulmaz, Elem
    Altunok, Elif Cigdem
    ARCHIVES OF RHEUMATOLOGY, 2020, 35 (03) : 385 - 393
  • [32] Intra- and inter-rater reliability for judgement of cough following citric acid inhalation
    Miles, Anna
    Huckabee, Maggie-Lee
    INTERNATIONAL JOURNAL OF SPEECH-LANGUAGE PATHOLOGY, 2013, 15 (02) : 209 - 215
  • [33] Development, intra- and inter-rater reliability of the New Zealand Secretion Scale (NZSS)
    Miles, Anna
    Hunting, Alexandra
    INTERNATIONAL JOURNAL OF SPEECH-LANGUAGE PATHOLOGY, 2019, 21 (04) : 377 - 384
  • [34] Intra-and Inter-Rater Reliability of Ultrasonographic Measurements of the Median Nerve Cross-Sectional Area of Filipinos
    Coronel, M.
    Domingo, P.
    Sy Cordero, J. Alphonse
    Sy Cordero, T. D. Alphonse
    Cruz, C. A. M.
    Chan, R. Y.
    Pua, J. H. C.
    EUROPEAN JOURNAL OF NEUROLOGY, 2021, 28 : 648 - 648
  • [35] Intra- and inter-rater reliability of muscle and fat thickness measurements obtained using portable ultrasonography in older adults
    de Oliveira, Gabriela Benatti
    Fernandes, Lara Vilar
    Chen, Xiayu Summer
    Andrade, Flavia Cristina Drumond
    Costa, Luciana Scarlazzari
    Vasques, Ana Carolina Junqueira
    Corona, Ligiana Pires
    CLINICAL NUTRITION ESPEN, 2024, 60 : 65 - 72
  • [36] INTER-RATER, INTRA-RATER, AND INTER-MACHINE RELIABILITY OF QUANTITATIVE ULTRASOUND MEASUREMENTS OF THE PATELLAR TENDON
    Gellhorn, Alfred C.
    Carlson, M. Jake
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2013, 39 (05): : 791 - 796
  • [37] Intra- and Inter-Rater Reliability of Three Measurements for Assessing Tactile Acuity in Individuals with Chronic Low Back Pain
    Wang, Juan
    Chen, Changcheng
    Peng, Mengsi
    Wang, Yizu
    Wu, Bao
    Zheng, Yili
    Wang, Xueqiang
    EVIDENCE-BASED COMPLEMENTARY AND ALTERNATIVE MEDICINE, 2020, 2020
  • [38] Using standardized scales to assess fear at veterinary visits: Intra- and inter-rater reliability
    Mercier, Pierrette
    Honeckman, Lynn
    Jokela, Fiia
    Dunham, Arthur E.
    Overall, Karen L.
    JOURNAL OF VETERINARY BEHAVIOR-CLINICAL APPLICATIONS AND RESEARCH, 2023, 62 : 12 - 17
  • [39] INTRA- AND INTER-RATER RELIABILITY OF THE SELECTIVE FUNCTIONAL MOVEMENT ASSESSMENT (SFMA) IN HEALTHY PARTICIPANTS
    Stanek, Justin M.
    Smith, Joshua
    Petrie, Jake
    INTERNATIONAL JOURNAL OF SPORTS PHYSICAL THERAPY, 2019, 14 (01): : 107 - 116
  • [40] Intra- and Inter-Rater Reliability of the Infant Motor Profile in Infants in Primary Health Care
    Tveten, Kine Melfald
    Hadders-Algra, Mijna
    Strand, Liv Inger
    Van Iersel, Patricia Anna Maria
    Rieber, Jannike
    Dragesund, Tove
    PHYSICAL & OCCUPATIONAL THERAPY IN PEDIATRICS, 2020, 40 (05) : 571 - 581