Intra- and inter-rater reliability in ultrasonographic measurements of coracohumeral distance

被引:0
|
作者
Guerra-Rodriguez, Diego [1 ]
Guerrero-Henriquez, Juan [2 ,3 ,7 ]
Basilio, Daniel [4 ]
Mendez-Rebolledo, Guillermo [5 ,6 ]
机构
[1] Univ Antofagasta, Fac Hlth Sci, Biomed Dept, Antofagasta, Chile
[2] Univ Antofagasta, Fac Hlth Sci, Rehabil & Human Movement Sci Dept, Antofagasta, Chile
[3] Univ Antofagasta, Fac Ciencias Salud, Ctr Invest Fisiol & Med Altura, Antofagasta, Chile
[4] Kinet K Integral Therapy & Training Ctr, Antofagasta, Chile
[5] Univ Santo Tomas, Escuela Kinesiol, Fac Salud, Lab Invest Somatosensorial & Motora, Santiago, Chile
[6] Univ Santo Tomas, Escuela Kinesiol, Fac Salud, Santiago, Chile
[7] Univ Antofagasta, Avda Univ Antofagasta 02800, Antofagasta 1240000, Chile
关键词
Ultrasonography; Reliability; Shoulder; Subacromial space;
D O I
10.1016/j.msksp.2024.102906
中图分类号
R49 [康复医学];
学科分类号
100215 ;
摘要
Background: Ultrasonography (US) is a widely used diagnostic tool in physical therapy. One of the US variables often utilized to quantify the dimensions of the subacromial space and its association with shoulder pathology is the coracohumeral distance (CHD), however, this measurement presents diverse evidence in terms of reliability. Objectives: To assess the intra- and inter-rater reliability of both expert and non-expert raters when measuring CHD through US in asymptomatic subjects. Additionally, we determined the effect of rater experience and measurement conditions on the recording of CHD. Methods: CHD of 15 individuals were recorded from US images of the glenohumeral joint of both upper extremities in three different positions. An expert and a non-expert rater in US usage recorded three CHD measurements, after a randomization procedure. To determine intra- and inter-rater reliability, the interclass correlation coefficient (ICC) and a multivariate variance model for the effects of rater experience, joint position and time of measure were used. Standard Error of Measurement and Minimal Detectable Change was also estimated for CHD measurements. Results: Intra-rater reliability ranged 0.970 to 0.998) and Inter-rater reliability ranged 0.48 to 0.876). Joint position (F2;55 = 38.308; p < 0.001; eta 2p = 0.582) and measurement time (F2;55 = 6.019; p = 0.004; eta 2p = 0.180) effect was observed on CHD. Conclusion: Excellent intra- and poor to moderate inter-rater reliability between expert and non-expert clinicians was determined, the latter being influenced by the position of the glenohumeral joint position at the time of US recording and the time of recording the measurement.
引用
收藏
页数:5
相关论文
共 50 条
  • [11] Intra- and inter-rater reliability for analysis of hyoid displacement measured with sonography
    Macrae, Phoebe R.
    Doeltgen, Sebastian H.
    Jones, Richard D.
    Huckabee, Maggie-Lee
    JOURNAL OF CLINICAL ULTRASOUND, 2012, 40 (02) : 74 - 78
  • [12] RETROSPECTIVE ASSESSMENTS OF INTRA- AND INTER-RATER RELIABILITY OF QUANTITATIVE FLOW RATIO
    Ishihara, Takayuki
    Takahara, Mitsuyoshi
    Tsujimura, Takuya
    Kurata, Naoya
    Iida, Osamu
    Asai, Mitsutoshi
    Masuda, Masaharu
    Okamoto, Shin
    Nanto, Kiyonori
    Kanda, Takashi
    Okuno, Shota
    Matsuda, Yasuhiro
    Kawai, Hiroyuki
    Tsuji, Aki
    Hata, Yosuke
    Uematsu, Hiroyuki
    Sato, Yuki
    Toyoshima, Taku
    Higashino, Naoko
    Mano, Toshiaki
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2019, 73 (09) : 1165 - 1165
  • [13] Intra- and inter-rater reliability of ultrasound measures of the anterior cruciate ligament
    Sievert, Zachary A.
    Bennett, Hunter J.
    Weinhandl, Joshua T.
    JOURNAL OF ULTRASOUND, 2021, 24 (01) : 49 - 55
  • [14] Intra- and inter-rater reliability of ultrasound measures of the anterior cruciate ligament
    Zachary A. Sievert
    Hunter J. Bennett
    Joshua T. Weinhandl
    Journal of Ultrasound, 2021, 24 : 49 - 55
  • [15] Intra- and inter-rater reliability of the BASRI, SASSS and mSASSS in ankylosing spondylitis
    Myckatyn, SO
    Oswald, AE
    Lambert, RG
    Spady, B
    Maksymowych, WP
    ANNALS OF THE RHEUMATIC DISEASES, 2004, 63 : 414 - 414
  • [16] Reproducibility of radiomics quality score: an intra- and inter-rater reliability study
    Akinci D'Antonoli, Tugba
    Cavallo, Armando Ugo
    Vernuccio, Federica
    Stanzione, Arnaldo
    Klontzas, Michail E.
    Cannella, Roberto
    Ugga, Lorenzo
    Baran, Agah
    Fanni, Salvatore Claudio
    Petrash, Ekaterina
    Ambrosini, Ilaria
    Cappellini, Luca Alessandro
    van Ooijen, Peter
    Kotter, Elmar
    Pinto dos Santos, Daniel
    Cuocolo, Renato
    EUROPEAN RADIOLOGY, 2024, 34 (04) : 2791 - 2804
  • [17] INTRA- AND INTER-RATER RELIABILITY OF THE SELECTIVE FUNCTIONAL MOVEMENT ASSESSMENT (SFMA)
    Glaws, Kathryn R.
    Juneau, Christopher M.
    Becker, Lindsay C.
    Di Stasi, Stephanie L.
    Hewett, Timothy E.
    INTERNATIONAL JOURNAL OF SPORTS PHYSICAL THERAPY, 2014, 9 (02): : 195 - 207
  • [18] Adjacent Joint Restriction Differentially Influences Intra- and Inter-rater Reliability and Agreement of Goniometric Measurements
    Pinto, Brendan L.
    Stankovic, Tatjana
    Frost, David M.
    Beach, Tyson A. C.
    INTERNATIONAL JOURNAL OF SPORTS PHYSICAL THERAPY, 2022, 17 (02): : 276 - 285
  • [19] Reproducibility of radiomics quality score: an intra- and inter-rater reliability study
    Tugba Akinci D’Antonoli
    Armando Ugo Cavallo
    Federica Vernuccio
    Arnaldo Stanzione
    Michail E. Klontzas
    Roberto Cannella
    Lorenzo Ugga
    Agah Baran
    Salvatore Claudio Fanni
    Ekaterina Petrash
    Ilaria Ambrosini
    Luca Alessandro Cappellini
    Peter van Ooijen
    Elmar Kotter
    Daniel Pinto dos Santos
    Renato Cuocolo
    European Radiology, 2024, 34 : 2791 - 2804
  • [20] Intra- and inter-rater reliability of jumping mechanography muscle function assessments
    Matheson, L. A.
    Duffy, S.
    Maroof, A.
    Gibbons, R.
    Duffy, C.
    Roth, J.
    JOURNAL OF MUSCULOSKELETAL & NEURONAL INTERACTIONS, 2013, 13 (04) : 480 - 486