Intra- and inter-rater reliability of jumping mechanography muscle function assessments

被引:0
|
作者
Matheson, L. A. [1 ]
Duffy, S. [1 ]
Maroof, A. [1 ]
Gibbons, R. [1 ]
Duffy, C. [1 ,2 ]
Roth, J. [1 ,2 ]
机构
[1] Childrens Hosp Eastern Ontario, Div Pediat Rheumatol, Ottawa, ON K1H 8L1, Canada
[2] Univ Ottawa, Dept Pediat, Ottawa, ON K1N 6N5, Canada
基金
加拿大健康研究院;
关键词
Reproducibility; Muscle Function; Mechanography; Force; Power; TEST-RETEST RELIABILITY; LEG STIFFNESS; STRIDE FREQUENCY; ANKLE STIFFNESS; COUNTERMOVEMENT; REPRODUCIBILITY; CHILDREN; HEIGHT; FORCE;
D O I
暂无
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
Muscle function can be assessed through jumping mechanography, where portable ground reaction force plates collect dynamic information as a subject jumps. The aim of this study was to assess both intra-and inter-rater reliability of jumping mechanography. Ten healthy adults underwent 3 sets of testing (collected by 3 different raters) at two separate sessions, one week apart. They performed a number of tests in each session: multiple one-legged hopping (M1LH; on right and left legs) and single two-legged jumps (S2LJ; with or without arm swing). The S2LJ assessed variables of power per body mass, jump height, velocity and efficiency; whereas, M1LH assessed maximum force per body mass and stiffness. Inter-rater coefficients of variation (CV) were less than 0.6% and 2.6% for the S2LJ and M1LH, respectively, for the primary outcome variables of power/body mass and force/body mass. Analyzing intra-rater results also produced CVs less than 5.3% for all variables. The present study reports that the Leonardo ground reaction force plate system yields reproducible results between sessions, without significant contribution of variability from the test operator. Jumping mechanography is an easy, safe and reliable method for the assessment of lower limb musculoskeletal function.
引用
收藏
页码:480 / 486
页数:7
相关论文
共 50 条
  • [1] Inter-Rater Reliability Of Jumping Mechanography In Healthy Children and Adults
    Roth, Johannes
    Duffy, Ciaran M.
    Bennett, Tania
    Erlandson, Marta
    Gibbon, Michele
    Macdonald, Heather
    Race, Douglas
    Ward, Leanne M.
    Tucker, Lori B.
    ARTHRITIS AND RHEUMATISM, 2013, 65 : S932 - S932
  • [2] RETROSPECTIVE ASSESSMENTS OF INTRA- AND INTER-RATER RELIABILITY OF QUANTITATIVE FLOW RATIO
    Ishihara, Takayuki
    Takahara, Mitsuyoshi
    Tsujimura, Takuya
    Kurata, Naoya
    Iida, Osamu
    Asai, Mitsutoshi
    Masuda, Masaharu
    Okamoto, Shin
    Nanto, Kiyonori
    Kanda, Takashi
    Okuno, Shota
    Matsuda, Yasuhiro
    Kawai, Hiroyuki
    Tsuji, Aki
    Hata, Yosuke
    Uematsu, Hiroyuki
    Sato, Yuki
    Toyoshima, Taku
    Higashino, Naoko
    Mano, Toshiaki
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2019, 73 (09) : 1165 - 1165
  • [3] Intra- and inter-rater reliability of the manual method of measuring respiratory muscle coordination
    Rodrigues, Antenor
    Xiong, Yijun
    Telias, Irene
    Goligher, Ewan
    Brochard, Laurent
    Reid, W. Darlene
    EUROPEAN RESPIRATORY JOURNAL, 2020, 56
  • [4] Intra- and inter-rater reliability for transvaginal cervical strain elastography
    Janssen, Matthew
    Koelper, Nathanael C.
    Weatherby, Michele
    Werth, Christina
    Schwartz, Nadav
    AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 2023, 228 (01) : S188 - S189
  • [5] Intra- and Inter-Rater Reliability of the Modified Tuck Jump Assessment
    Fort-Vanmeerhaeghe, Azahara
    Montalvo, Alicia M.
    Lloyd, Rhodri S.
    Read, Paul
    Myer, Gregory D.
    JOURNAL OF SPORTS SCIENCE AND MEDICINE, 2017, 16 (01) : 117 - 124
  • [6] Intra- and inter-rater reliability in ultrasonographic measurements of coracohumeral distance
    Guerra-Rodriguez, Diego
    Guerrero-Henriquez, Juan
    Basilio, Daniel
    Mendez-Rebolledo, Guillermo
    MUSCULOSKELETAL SCIENCE AND PRACTICE, 2024, 69
  • [7] Intra- and inter-rater reliability of the assessment of capacity for myoelectric control
    Hermansson, LM
    Bodin, L
    Eliasson, AC
    JOURNAL OF REHABILITATION MEDICINE, 2006, 38 (02) : 118 - 123
  • [8] INTRA- AND INTER-RATER RELIABILITY OF HYOID DISPLACEMENT MEASURED BY ULTRASOUND
    Macrae, Phoebe
    Huckabee, M.
    Doeltgen, S.
    Jones, R.
    DYSPHAGIA, 2009, 24 (04) : 482 - 483
  • [9] Intra- and inter-rater reliability of the Multiple Sclerosis Functional Composite
    Fischer, JS
    Cohen, JA
    Cutter, GR
    Mertz, LA
    Bolibrush, DM
    Skaramagas, TT
    Jak, AJ
    Kniker, JE
    NEUROLOGY, 1999, 52 (06) : A548 - A548
  • [10] Intra- And Inter-rater Reliability Of Panoramic Ultrasound Muscle Image Quantification Of The Quadriceps Femoris
    Cleary, Christopher John, Jr.
    Nabavizadeh, Omid
    Young, Kaycie
    Herda, Ashley A.
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2021, 53 (08): : 108 - 108