Intra- and inter-rater reliability of jumping mechanography muscle function assessments

被引:0
|
作者
Matheson, L. A. [1 ]
Duffy, S. [1 ]
Maroof, A. [1 ]
Gibbons, R. [1 ]
Duffy, C. [1 ,2 ]
Roth, J. [1 ,2 ]
机构
[1] Childrens Hosp Eastern Ontario, Div Pediat Rheumatol, Ottawa, ON K1H 8L1, Canada
[2] Univ Ottawa, Dept Pediat, Ottawa, ON K1N 6N5, Canada
基金
加拿大健康研究院;
关键词
Reproducibility; Muscle Function; Mechanography; Force; Power; TEST-RETEST RELIABILITY; LEG STIFFNESS; STRIDE FREQUENCY; ANKLE STIFFNESS; COUNTERMOVEMENT; REPRODUCIBILITY; CHILDREN; HEIGHT; FORCE;
D O I
暂无
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
Muscle function can be assessed through jumping mechanography, where portable ground reaction force plates collect dynamic information as a subject jumps. The aim of this study was to assess both intra-and inter-rater reliability of jumping mechanography. Ten healthy adults underwent 3 sets of testing (collected by 3 different raters) at two separate sessions, one week apart. They performed a number of tests in each session: multiple one-legged hopping (M1LH; on right and left legs) and single two-legged jumps (S2LJ; with or without arm swing). The S2LJ assessed variables of power per body mass, jump height, velocity and efficiency; whereas, M1LH assessed maximum force per body mass and stiffness. Inter-rater coefficients of variation (CV) were less than 0.6% and 2.6% for the S2LJ and M1LH, respectively, for the primary outcome variables of power/body mass and force/body mass. Analyzing intra-rater results also produced CVs less than 5.3% for all variables. The present study reports that the Leonardo ground reaction force plate system yields reproducible results between sessions, without significant contribution of variability from the test operator. Jumping mechanography is an easy, safe and reliable method for the assessment of lower limb musculoskeletal function.
引用
收藏
页码:480 / 486
页数:7
相关论文
共 50 条
  • [21] INTRA- AND INTER-RATER RELIABILITY OF THE SELECTIVE FUNCTIONAL MOVEMENT ASSESSMENT (SFMA)
    Glaws, Kathryn R.
    Juneau, Christopher M.
    Becker, Lindsay C.
    Di Stasi, Stephanie L.
    Hewett, Timothy E.
    INTERNATIONAL JOURNAL OF SPORTS PHYSICAL THERAPY, 2014, 9 (02): : 195 - 207
  • [22] Reproducibility of radiomics quality score: an intra- and inter-rater reliability study
    Tugba Akinci D’Antonoli
    Armando Ugo Cavallo
    Federica Vernuccio
    Arnaldo Stanzione
    Michail E. Klontzas
    Roberto Cannella
    Lorenzo Ugga
    Agah Baran
    Salvatore Claudio Fanni
    Ekaterina Petrash
    Ilaria Ambrosini
    Luca Alessandro Cappellini
    Peter van Ooijen
    Elmar Kotter
    Daniel Pinto dos Santos
    Renato Cuocolo
    European Radiology, 2024, 34 : 2791 - 2804
  • [23] Development of the Finnish neurological function testing battery for dogs and its intra- and inter-rater reliability
    Anna Fredrika Boström
    Heli Katariina Hyytiäinen
    Petteri Koho
    Sigitas Cizinauskas
    Anna Katrina Hielm-Björkman
    Acta Veterinaria Scandinavica, 60
  • [24] Development of the Finnish neurological function testing battery for dogs and its intra- and inter-rater reliability
    Bostrom, Anna Fredrika
    Hyytiainen, Heli Katariina
    Koho, Petteri
    Cizinauskas, Sigitas
    Hielm-Bjorkman, Anna Katrina
    ACTA VETERINARIA SCANDINAVICA, 2018, 60
  • [25] Inter-Rater Reliability and Measurement Error of Sonographic Muscle Architecture Assessments
    Koenig, Niklas
    Cassel, Michael
    Intziegianni, Konstantina
    Mayer, Frank
    JOURNAL OF ULTRASOUND IN MEDICINE, 2014, 33 (05) : 769 - 777
  • [26] The inter-rater reliability of mental capacity assessments
    Raymont, Vanessa
    Buchanan, Alec
    David, Anthony S.
    Hayward, Peter
    Wessely, Simon
    Hotopf, Matthew
    INTERNATIONAL JOURNAL OF LAW AND PSYCHIATRY, 2007, 30 (02) : 112 - 117
  • [27] The intra- and inter-rater reliability of five clinical muscle performance tests in patients with and without neck pain
    Tina Juul
    Henning Langberg
    Flemming Enoch
    Karen Søgaard
    BMC Musculoskeletal Disorders, 14
  • [28] The intra- and inter-rater reliability of five clinical muscle performance tests in patients with and without neck pain
    Juul, Tina
    Langberg, Henning
    Enoch, Flemming
    Sogaard, Karen
    BMC MUSCULOSKELETAL DISORDERS, 2013, 14
  • [29] Intra- and inter-rater reliability of rectus femoris muscle thickness measured using ultrasonography in healthy individuals
    Takahashi, Yosuke
    Fujino, Yuji
    Miura, Kohei
    Toida, Ayumi
    Matsuda, Tadamitsu
    Makita, Shigeru
    ULTRASOUND JOURNAL, 2021, 13 (01):
  • [30] Intra- and inter-rater reliability of rectus femoris muscle thickness measured using ultrasonography in healthy individuals
    Yosuke Takahashi
    Yuji Fujino
    Kohei Miura
    Ayumi Toida
    Tadamitsu Matsuda
    Shigeru Makita
    The Ultrasound Journal, 13