Intra and inter-rater reliability of skin fold measurements in university men

被引:0
|
作者
de Oliveira Filho, Aluizio Picanco [1 ]
de Brito, Alex Lima [1 ]
Viana, Albert da Silva [1 ]
de Sousa de Lima Deniur, Jose Rodrigo [1 ]
de Azevedo Albuquerque, Ana Paula [1 ]
Pureza, Demilto Yamaguchida [1 ]
Materko, Wollner [1 ]
机构
[1] Univ Fed Amapa UNIFAP, Escola Educ Fis, Lab Biodinam Movimento Humano, Macapa, AP, Brazil
来源
关键词
Inter-rater; Skin folds; Intra-rater; Reliability;
D O I
暂无
中图分类号
G8 [体育];
学科分类号
04 ; 0403 ;
摘要
The purpose of the present study was to compare the intra and inter-rater reliability of skin fold thickness pectoral (STP), abdomen (STA) and thigh (STT) in university men. It was a sample of 17 men (18 until 41 years old) and physically active. All volunteers were submitted to an anthropometric evaluation and measurement of the three skin folds by a same evaluator to study the intra-rater reliability through Anova by repetitive measures and Bonferroni pos hoc test and the intra-rater reliability based in the value of the mean of the three measures for each skin fold by Anova one-way and the Tukey post hoc test. All tests assumed = 0.05. The results of the skin fold values obtained for the same evaluator in three attempts in STP (12.0 +/- 1.7 mm, 12.0 +/- 1.6 mm and 11.9 +/- 1.6 mm), STA (21, 7 +/- 2.5 mm, 20.4 +/- 2.5 mm and 20.3 +/- 2.4 mm) and STT (15.0 +/- 1.6 mm, 15.4 +/- 1.7 mm and 14.7 +/- 1.5 mm), showing no significant difference in all skin folds. When comparing the results mean difference between the evaluators of 1.2 mm, 1.4 mm and 0.4 mm, respectively, for STP, STA and STT, no showing significant difference. In conclusion, the results in the comparison of skin fold measurements in the intra-rater and inter-rater evaluation, a high correlation (r = 0.91-0.99, p < 0.01) could be observed for all skin folds. In conclusion, the results of the present study showed a good intra-rater reliability and inter-rater in the measurements of skin folds in university men.
引用
收藏
页码:1079 / 1085
页数:7
相关论文
共 50 条
  • [1] Inter-Rater and Intra-Rater Reliability of the Kansas University Sitting Balance Scale
    Franc, Ingrid
    Roberts, Magdalea
    Mauldin, Samantha
    Rosa-Distefano, Gregoria
    AMERICAN JOURNAL OF OCCUPATIONAL THERAPY, 2019, 73 (04):
  • [2] Inter-Rater and Intra-Rater Reliability of the Kansas University Sitting Balance Scale
    Franc, Ingrid A.
    Mauldin, Samantha
    Roberts, Magdalena
    Rosa-DiStefano, Gregoria
    OCCUPATIONAL THERAPY IN HEALTH CARE, 2023, 37 (04) : 595 - 605
  • [3] Inter-Rater and Intra-Rater Reliability of Sonographic Median Nerve and Wrist Measurements
    Gonzalez-Suarez, Consuelo B.
    Buenavente, Ma Lorraine D.
    Cua, Ronald Christopher A.
    Fidel, Maria Belinda C.
    Cabrera, Jan-Tyrone C.
    Regala, Carina Fatima G.
    JOURNAL OF MEDICAL ULTRASOUND, 2018, 26 (01) : 14 - 23
  • [4] Intra-rater and inter-rater reliability of 3D facial measurements
    Hobbs-Murphy, Kayna
    Olmedo-Nockideneh, Isabel
    Brazile, William J.
    Morris, Kristen
    Rosecrance, John
    APPLIED ERGONOMICS, 2024, 116
  • [5] Intra- and inter-rater reliability in ultrasonographic measurements of coracohumeral distance
    Guerra-Rodriguez, Diego
    Guerrero-Henriquez, Juan
    Basilio, Daniel
    Mendez-Rebolledo, Guillermo
    MUSCULOSKELETAL SCIENCE AND PRACTICE, 2024, 69
  • [6] INTER-RATER, INTRA-RATER, AND INTER-MACHINE RELIABILITY OF QUANTITATIVE ULTRASOUND MEASUREMENTS OF THE PATELLAR TENDON
    Gellhorn, Alfred C.
    Carlson, M. Jake
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2013, 39 (05): : 791 - 796
  • [7] INTRA AND INTER-RATER RELIABILITY STUDY OF THE DYNAMOMETRIC MEASUREMENTS OF THE PELVIC FLOOR MUSCLES
    Martinho, N.
    Marques, J.
    Silva, V
    Lanziotti, S.
    Riccetto, C.
    Botelho, S.
    NEUROUROLOGY AND URODYNAMICS, 2014, 33 (06) : 983 - 984
  • [8] Intra and inter-rater reliability study of pelvic floor muscle dynamometric measurements
    Martinho, Natalia M.
    Marques, Joseane
    Silva, Valeria R.
    Silva, Silvia L. A.
    Carvalho, Leonardo C.
    Botelho, Simone
    BRAZILIAN JOURNAL OF PHYSICAL THERAPY, 2015, 19 (02) : 97 - 104
  • [9] Intra-rater and inter-rater reliability of robotic arthrometer DYNEELAX®
    Mihalinec, Katja
    Martinez-Cepa, Carmen B.
    Zuil-Escobar, Juan C.
    Kejzar, Natasa
    Vauhnik, Renata
    JOURNAL OF EXPERIMENTAL ORTHOPAEDICS, 2024, 11 (03)
  • [10] Measuring Essay Assessment: Intra-rater and Inter-rater Reliability
    Kayapinar, Ulas